website http://www.lgservice.com
IMPORTANT
• Please read this installation manual completely before
installing the product.
• Installation work must be performed in accordance with
the national wiring standards by authorized personnel
only.
• Please retain this installation manual for future reference
after reading it thoroughly.

2Cassette type Air Conditioner
Cassette Type Air Conditioner Installation Manual
TABLE OF CONTENTS
Safety Precautions .....3
Installation of Indoor,
Outdoor unit................6
Ceiling opening
dimensions and hanging
bolt location
..................8
The indoor unit
installation...................9
Remote controller
installation...................9
Wiring connection ....11
Connecting Pipes to
the Indoor Unit ..........13
Installation of
decorative panel .......15
Indoor unit drain piping
....................................16
Test running ..............19
Optional operation....21
•
Connecting cable
• Four Type "A" Screw
• Hanging Bolt
(W 3/8 or M10 length 650mm)
• Pipes: Gas side
Liquid side
• Insulated drain hose
• Additional Drain hose
(Inner Dia.............32mm)
•
Level
•
Screw driver
•
Electric drill
•
Hole core drill (ø70mm)
• Flaring Tools set
• Torque Wrenches
• Hexagonal Wrench (4mm, 5mm)
• Gas-leak detector
•
Owner’s Manual
•
Thermometer
Installation
Requirements Required Parts Required Tools

Safety Precautions
Installation Manual 3
ENGLISH
To prevent injury to the user or other people and property damage, the following instructions
must be followed.
■
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness
is classified by the following indications.
■Meanings of symbols used in this manual are as shown below.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
WARNING
Be sure not to do.
Be sure to follow the instruction.
Safety Precautions
■Installation
Install the panel and the cover of
control box securely.
• There is risk of fire or
electric shock.
Always install a dedicated
circuit and breaker.
• Improper wiring or
installation may cause fire or
electric shock
Use the correctly rated breaker
or fuse.
• There is risk of fire or
electric shock.
Do not use a defective or
underrated circuit breaker. Use
this appliance on a dedicated
circuit.
• There is risk of fire or
electric shock.
For electrical work, contact the
dealer, seller, a qualified
electrician, or an Authorized
Service Center.
•
Do not disassemble or repair
the product. There is risk of
fire or electric shock.
Always ground the product.
• There is risk of fire or
electric shock.
Product specificaties
Merk: | LG |
Categorie: | Airco |
Model: | AUUW126B |
Heb je hulp nodig?
Als je hulp nodig hebt met LG AUUW126B stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airco LG
8 Juni 2025
7 Juni 2025
7 Juni 2025
7 Juni 2025
28 Maart 2025
26 Maart 2025
26 Maart 2025
26 Maart 2025
26 Maart 2025
20 Februari 2025
Handleiding Airco
- Everglades
- Innoliving
- Gutfels
- Climachill
- Finlux
- Cecotec
- GoldAir
- SereneLife
- Comfee
- Orima
- Crosley
- SHE
- DEXP
- Thomson
- Carrefour Home
Nieuwste handleidingen voor Airco
17 Juni 2025
17 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025