Bekijk gratis de handleiding van Kimo CT 50 (12 pagina’s), behorend tot de categorie Meetapparatuur. Deze gids werd als nuttig beoordeeld door 9 mensen en kreeg gemiddeld 3.7 sterren uit 5 reviews. Heb je een vraag over Kimo CT 50 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/12

English
Quick Start Guide
Class 50 portables
2. Take a measurement
Switch on the instrument by pressing briey on “On/Off/Hold”.
The instrument displays its name then the measurement.
VT 50: before using the instrument with the
hotwire probe, please lower the protection
tube (1) of the sensing element.
VT 50: always use the hotwire probe with
the red point in front of ow.
CO 50: the instrument displays its name then a 5 second countdown. This count corresponds to the preheating
time of the sensor. At the end of the countdown, the measured value of CO is displayed.
MP 50, MP 51: the instrument displays its name then an autozero is performed. At the end of the autozero, the
measured value displays.
Press briey on “Select” to switch measurement parameter display.
MP 50, MP 51, MP 55: press briey and successively on “Select” to change the unit.
• Available units for MP 50: Pa, mmH
2
0, inWg, daPa.
• Available units for MP 51: mmH
2
0, kPa, in Wg, mbar, mmHg, daPa.
• Available units for MP 55: mbar, mmHg, hPa.
HM 50: press briey on “Select” to select a type of material.
Press the spikes in the material to be measured.
When a measurement is over-range, above the maximum range, the value ashes.
Below the minimum range, the value is no more measurable and the device indicates "---", it means that for:
• Wood type 1: the measurement is < than 10%
• Wood type 2: the measurement is < than 9%
• Plaster, brick and concrete: the measurement is < than 0.1%
1. Keys
Select
On/Off/Hold
Sensing
element
(temperature)
Sensing
element
(velocity)
Airow direction
Protection tube
of the sensing
element (1)
Redpoint: landmark
Bottom of the
hotwire probe
4. Hold the measurement
During measurement, press briey on “On/Off/Hold” to hold measurement: “Hold” appears on the screen and
measurements are xed.
During measurement:
Remove pressure tubes. Carry out a long press on “Select”.
The instrument makes an autozero then returns to the measurement display.
3. Carry out a manual autozero (MP 50, MP 51)
CO 50, HD 50, HM 50, LX 50, MP 55, VT 50: press briey on “Select” to move from one parameter to the other.
Press again briey on “On/Off/Hold” to exit the Hold function.
These portable instruments are used to measure the following parameters: temperature, relative humidity, CO, pressure,
air velocity and light.
1. Operating temperature, protection of the instruments and information about storage
Conditions of use (°C/%RH/m): from 0 to +50 °C. In non-condensing conditions. From 0 to 2000 m.
Protection: IP54
Storage temperature: HD 50, LX 50: from -20 to +70 °C. CT 50, CO 50, HM 50, LV 50, MP 50, MP 51, MP 55, VT 50: from -20 to +80 °C.
If the instrument is stored outside the operating temperature (for example in a van, a warehouse...), please wait for 10
minutes in its operating temperature before start using it.
Product specificaties
Merk: | Kimo |
Categorie: | Meetapparatuur |
Model: | CT 50 |
Heb je hulp nodig?
Als je hulp nodig hebt met Kimo CT 50 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Meetapparatuur Kimo
2 September 2025
2 September 2025
2 September 2025
2 September 2025
1 September 2025
1 September 2025
1 September 2025
1 September 2025
1 September 2025
1 September 2025
Handleiding Meetapparatuur
- Trotec
- Bohle
- Testec
- Topex
- Werma
- GlowShift
- TDE Instruments
- Benning
- Uni-T
- SKS
- Pioneer
- Truelife
- Albrecht
- Wachendorff
- Technics
Nieuwste handleidingen voor Meetapparatuur
2 September 2025
2 September 2025
2 September 2025
2 September 2025
2 September 2025
2 September 2025
1 September 2025
1 September 2025
1 September 2025
1 September 2025