Kenton MERGE-4 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Kenton MERGE-4 (4 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 24 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
MMMMEEEERRRRGGGGEEEE----4444
4 into 2 MIDI Merge Box
Operating manual
2
Description
The MERGE-4 has four MIDI Inputs and two MIDI Out ports to enable you to connect
several MIDI devices to one or two MIDI inputs.
The MERGE-4 has opto-coupled MIDI Inputs and separate drive circuits for each
MIDI Out socket for optimum performance. The MERGE-4 also contains active
circuitry that can restore the quality of signals received at the MIDI Input that may
have become degraded by losses in the MIDI cable.
The MERGE-4 is powered by a mains adaptor (supplied), so it doesn’t need periodic
battery changes to keep it working, enabling you to “fit and forget”.
Connecting
Ensure that the power adaptor is plugged in, and the ACTIVE LED on the MERGE-4
is on. Connect the MIDI output of your keyboard(s) and/or computer to the MIDI
Inputs of the MERGE-4 and connect one of the MIDI Out ports of the MERGE-4 to
the MIDI input of the device you want to control.
Do not connect any of the MIDI Out ports of the MERGE-4 back to the MIDI Input of
the device which is supplying data to the MIDI In port of the MERGE-4, as this may
cause a MIDI loop to occur. This may cause note hangs or other undesirable effects.
Merging Rules
You may find it useful to have an understanding of the following rules which the
Merge-4 uses when handling certain types of MIDI data. The Merge-4 defines one of
the four inputs as the master input for each of the following data types. One input
may be the master for one or more data types whilst a different input may be the
master for another data type.
MIDI Clock
When power is first applied, no input is defined as a master and all clock messages
from all inputs will be passed until one input is defined as a master.
The most recent input to receive a START command (or Song Position Pointer=0
followed by CONTINUE) will become the clock master.
That input continues to be the clock master until another input satisfies the above
condition.
Active Sensing
The first input to receive an Active Sensing message will become the Active Sensing
master. Active sensing messages from that input will be passed to the output, any
active sensing messages received at other inputs will be ignored. An input will stay
as Active Sensing master until no more Active Sensing messages are received at
that input for a period of around 5 seconds. Then another input has the opportunity
to become the Active Sensing master.
3
Sysex Messages
While any input is handling a SysEx message it becomes the SysEx master, and
SysEx messages from all other inputs will be locked out until the message at the
master input has finished.
SysEX messages may be terminated either with an End Of Sysex command (F7) or
with any other status command .
Firmware version Request:
A firmware version request must be issued within 10 seconds of power being applied
to the unit, otherwise it will be ignored.
The firmware version request message is - F0 00 20 13 0E 60 F7 (hex)
The unit replies with the version number as F0 00 20 13 0E 6F xx xx xx xx F7 (hex).
Where xx is a number in ASCII and the leftmost digit is the most significant.
For example - F0 00 20 13 0E 6F 31 32 33 34 F7 (hex) = version number 1234


Product specificaties

Merk: Kenton
Categorie: Niet gecategoriseerd
Model: MERGE-4

Heb je hulp nodig?

Als je hulp nodig hebt met Kenton MERGE-4 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Kenton

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd