Bekijk gratis de handleiding van Kathrein UAS 582 (8 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 55 mensen en kreeg gemiddeld 4.1 sterren uit 28 reviews. Heb je een vraag over Kathrein UAS 582 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/8

1 / 8
Universal Wideband feed system 10,70-12,75 GHz
About this Guide
This document is part of the product.
►Read these instructions for use before the initial use of
the antenna set.
►Perform all operating steps described in the manuals
in the specifi ed sequence.
For the most up-to-date version of this document, go to
www.kathrein-ds.com.
Keep these instructions for future reference.
Pass them on to any new owners when
selling or transferring the unit.
Features
■Universal Wideband feed system with 2 outputs
■Suitable for Kathrein o set parabolic antennas, type CAS.. (60, 80, 90, 120 cm Ø)
■For reception of satellites in the Ku band, such as ASTRA, EUTELSAT and TürkSat
■50% less cable material required: To receive one satellite, only two cables from the LNB to the wideband multiswitch
are required, with Multifeed, two satellites can be received with just four cables
■Energy saving - only max. 1,2 W power consumption
■The feed system complies with ASTRA specifi cations for universal Wideband feed systems
■Power supply via coax cable
■Multifeed-suitable due to compact design
■Full protection of LNB and cable connections in a ventilated housing, protection category IP 54
■UAS 582
■2 x F-type plug
■Azimut-/elevations table
■Instructions for use
Transport and Storage
►Transport and store the device in its original packaging.
►Make sure there is no water condensation build-up.
Intended Use
►The device described is designed solely for the installation of satellite receiver systems and may only be installed by
trained specialist personnel.
►The UAS 582 feed system may only be mounted to the listed Kathrein parabolic antennas.
►If it is used in any other way or if the provisions of this document are disregarded, the guarantee and warranty will
become void.
►The manufacturer is not liable for accidents caused by the user on the opened device.
►Unauthorized opening and repair attempts lead to the loss of the warranty claim.
Scope of Delivery
UAS 582 20110032

2 / 8
Safety Instructions
The UAS 582 feed system may only be mounted to the listed Kathrein parabolic antennas. The feed
system is subject to the same safety and danger warnings as listed in the instructions for using of
fset parabolic antennas. Please follow these instructions at all times, as otherwise you or other
people may be exposed to danger (electric shock through overhead lines, risk of falling down, falling
parts, thunderstorm etc.).
Mounting and Connection of the feed system
Fixing the feed system (Fig. 1)
1. Position the feed system as desired on the multifeed
plate at the end of the bracket (see antenna instruc-
tions)
2. Fasten the feed system on the front part using the
Allen wrench (torque: 4.5 Nm).
All fastening and tightening can be e ected
with a Allen wrench (SW4).
Hier ansetzen
MA
= 4,5 Nm
Setting the polarisation (Fig. 2)
See the value in the table Tab. 1,S.5 for the polarisa-
tion setting.
If the value di ers from the pre-set 0°, proceed as follows:
1. Loosen both Allen screws (S).
2. Turn the feed system to set the reference mark to the
value given in the polarisation pre-setting table.
3. Tighten the Allen screws (S) evenly, alternating
between both.
Torque: max. 4.5 Nm
Polarisation 0°
Polarisation +15°
Polarisation -15°
Allen screw (S)
Fig. 1: Fixing the feed system
Fig. 2: Setting the polarisation

3 / 8
Cable connection
1. Loosen the Allen screws (S) at the rear end of the
cover until the cover can be unlocked by applying light
downward pressure ; remove cover .① ②
If the feed system is not only exchanged but
a new antenna system is being installed,
proceed fi rst as described in the section
“Aligning the satellite reception system” and
then return to “Cable connection”.
2. Mount the supplied F-type plug onto the Kathrein
cable types LCD 90, LCD 111A+, LCD 115A+ oder LCD
120A+ montieren and connect to the LNB (see Fig. 4).
3. When connecting the matrix and the LNB, make sure
the correct output is assigned (mark cables if neces-
sary).
4. It is important to ensure that the bending radius of the
corresponding cable is not undershot.
5. Lead the connected cable forwards and insert side-
ways into the cable fastening (see close-up in Fig. 5
below).
6. Slide on the cover until it fi ts into the groove and locks
in the bottom section. Tighten Allen screw (S).
Allen screw (S)
①
②
Fig. 3: Remove cover
6,5 mm
6,5 mm
flush
Fig. 4: Plug mounting
2 x
Fig. 5: Cable connection
Product specificaties
Merk: | Kathrein |
Categorie: | Niet gecategoriseerd |
Model: | UAS 582 |
Kleur van het product: | Grijs |
Gewicht: | 800 g |
Breedte: | 44 mm |
Diepte: | 135 mm |
Hoogte: | 235 mm |
Breedte verpakking: | 65 mm |
Diepte verpakking: | 185 mm |
Hoogte verpakking: | 295 mm |
Land van herkomst: | Duitsland |
Aantal RF-poorten: | 2 |
Aantal: | 1 |
Stroomverbruik: | 1200 mA |
RF aansluitingstype: | F |
Output impedance: | 75 Ohm |
Input frequentiebereik: | 10.7 - 12.75 GHz |
Output frequentiebereik: | 300 - 2350 MHz |
Oscillatie frequentie: | 10.4 |
Winst: | 50 dB |
X-polarisatie: | 22 dB |
Lokale oscillator (LO) ruisfase (10 kHz): | 95 dBc/Hz |
Heb je hulp nodig?
Als je hulp nodig hebt met Kathrein UAS 582 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Kathrein
12 Mei 2025
8 Mei 2025
5 Februari 2025
28 Januari 2025
24 Mei 2024
24 Mei 2024
6 December 2023
13 Juni 2023
8 Juni 2023
23 Mei 2023
Handleiding Niet gecategoriseerd
- Schneider
- Gagato
- BIOS Living
- Maclean
- Esatto
- Ontech
- COMSOON
- Proteca
- Rexel
- Badiona
- Ciarra
- Dracast
- Bluebird
- Franklin
- Merging
Nieuwste handleidingen voor Niet gecategoriseerd
20 Juni 2025
20 Juni 2025
20 Juni 2025
20 Juni 2025
20 Juni 2025
20 Juni 2025
20 Juni 2025
20 Juni 2025
20 Juni 2025
20 Juni 2025