Bekijk gratis de handleiding van Jung WSK100 REG (7 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.7 sterren uit 1.5 reviews. Heb je een vraag over Jung WSK100 REG of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/7
Blinds Management Weather station
Ref.-no.: WSK 100 REG
Operating Instructions
Weather station
1. Safety Warnings
Electrical equipment must be installed and fitted by qualified
electricians only and in strict observance of the relevant accident
prevention regulations.
Failure to observe any of the installation instructions may result in
fire and other hazards.
The terminal block for connection of the combination sensor must
be plugged on before the mains voltage is applied and during
operation in order to protect the digital input against accidental
contact with live wires. Risk of irreparable damage to the device!
2. Function
In conjunction with the digital combination sensor WS10 KS and the
power supply unit WSSV10, the weather station WSK100 REG measures
brightness, wind intensity and rain.
Based on brightness and wind intensity, the station controls a connected
shutter control system independently for the east, south and west sides of
a house.
The precipitation detect function can, for instance, be used for closing
skylights when it rains.
Stand: Jul-08 82558003
Blinds Management Weather station
Ref.-no.: WSK 100 REG
3. Features
Independent outputs for the shutters of the east, south and west
facade of a house
Separately adjustable shading function for the east, south and west
facade
Presettable common limit value for the wind alarm for the three
house facades
Precipitation detect function with switched ouput, e.g. for the control
of skylights
Standard shutter moving time of 2.5 minutes in sun protection mode
can be shortened independently for each facade
Monitoring of combination sensor connection cable with alarm
function and message display.
4. Installation
The device is snap-fastened on a 35 x 7.5 mm rail as per DIN EN 50022.
Important
The terminal block for connection of the combination sensor must
be plugged on before the mains voltage is applied and during
operation in order to protect the digital input against accidental
contact with live wires. Risk of irreparable damage to the device.
For operation, the weather station needs an external 24 V power supply
unit (WSSV10). After switching on the power supply, the green Power
LED (10) is lit up.
Combination sensor wiring diagramm
4.1. Combination sensor connection
The power supply is connected to the screw terminals +AC/DC 24V -.
The external voltage of 24 V supplies also the heating of the combination
sensor via the pink + (pi) and grey - (gy) wires.
The data lines of the combination sensor are connected by means of the
4-pole terminal block WAGO, type 252-104 supplied with the combination
sensor. Observe the colour code when connecting the terminal block.
From left to right: green (gr), yellow (ye), white (wh), brown (br)
2
Blinds Management Weather station
Ref.-no.: WSK 100 REG
If possible, connect the green-yellow wire of the cable (shield) to ground
potential. If this is not possible, the shield must remain unconnected.
Rain detector wiring diagramm
4.2. Rain detector connection
Via a switched phase conductor (L), the relay output Regen/Rain can
control the extension input (terminal 1
) of a motor control insert 232
ME, for instance, for closing a skylight when it rains.
The relay output Alarm can be used, for instance, to visualize an alarm
condition by means of a signal lamp (see chapter Alarm function)
Shutter wiring diagramm
4.3. Shutter connection
The relay contacts are connected to a mains phase conductor (L).
Shading control: To cause the connected shutter control system to move
the shutters downs when the sun is shining, relay outputs
1 to 3
are connected with the extension inputs (terminal 1
) of the motor
control inserts 232 ME.
Wind monitoring: To move the shutters up into the safety position in
strong wind, the relay outputs Wind 1 to Wind 3 are connected to the
extension inputs (terminal 2
) of the motor control inserts 232 ME.