Bekijk gratis de handleiding van Jung CD 134.18 WU (5 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 6 mensen en kreeg gemiddeld 4.4 sterren uit 3.5 reviews. Heb je een vraag over Jung CD 134.18 WU of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/5
Key switches
20.11.20241 / 50024096301
Key switches
without protection against dismounting
Ref.-no.: 104.15, 106.15, 133.15, 134.15
with protection against dismounting
Ref.-no.: 104.28, 106.28, 133.18,
134.18, 138.18, 134.28
Ref.-no.: CD 104.18 WU, CD 106.18 WU,
CD 133.18 WU, CD 134.18 WU
Operating instructions
1 Safety instructions
Electrical devices may only be installed and connected by electrically skilled persons.
Serious injuries, re or property damage possible. Please read and follow the instructions in full.
These instructions are an integral part of the product, and must remain with the end customer.
2 Device components
Abb. 1: Geräteaufbau
(1) Sealing gasket (see accessories)
(2) Insert
(3) Frame
(4) Prole half cylinder
(5) Centre plate
3 Function
Intended use
- for prole half cylinder with approx. 40 mm overall length (DIN 18252), e.g. art. no.: 28, 28 G1
- not suitable for installation in surface caps
1 32 4 5 5
GB
Key switches
20.11.20242 / 50024096301
Designs
Blind reversing switch, 1-pole (1 motor)
104.15, CD 104.18 WU
Blind reversing push-button, 1-pole (1 motor)
134.15, 134.18, CD 134.18 WU
Blind reversing switch, 2-pole (2 motors)
104.28
Blind reversing push-button, 2-pole (2 motors)
134.28
Push-button (2-way), 1-pole
133.15, 133.18, CD 133.18 WU
Control push-button, 1 NC contact – 1 NO contact
138.18
Universal-o󰀨 2-way switch, 1-pole
106.15, CD 106.18 WU
Universal-o󰀨 2-way switch, 2-pole
106.28
4 Information for electrically skilled persons
Mounting and electrical connection
DANGER
Electrical shock on contact with live parts in the installation environment.
Electrical shocks can be fatal.
Before working on the device, disconnect the power and cover live parts in the area!
Connecting ush-mounted inserts
Only for inserts with IP44:
Feed the cable through the sealing gasket.
Connect the insert according to the connection diagram. (g. 5 to g. 10)
Adjusting the cam on the prole half cylinder
180°
300°
240°
210°
330°
30°
60°
90°
120°
150°
270°
Fig. 2 and 3: Adjusting the cam on the prole half cylinder
Example:
- Adjustable cam (6) on a prole half cylinder with 12 positions (0° to 330°)
- Fork (7) of a blind switch in the Stop switching state, for switching states see chapter operation
Set the cam so that it is either located inside the fork or engages with the fork from the outside after the locking
cylinder has been mounted.
For this, use a screwdriver to press down on the two locking pins (8) and turn the cam into position. Only one of
the two locking pins can be pressed down at a time.
- Cam inside the fork:
The key can only be removed in the Stop or Centre/O󰀨 switching state.
- Cam on the outside of the fork:
The key can also be removed in the Up/Down or On switching state.
- Only ush-mounted inserts with protection against dismounting:
Consider protection against dismounting, see chapter dismounting.
76
8 8
Key switches
20.11.20243 / 50024096301
Installing the prole half cylinder
See gure 1
Fasten the locking cylinder (4) to the centre plate (5) using the included screw.
iIf other locking cylinders are used, these may only have an opening for keys on one side. Otherwise IP44 is not
possible.
Dismounting
Flush-mounted inserts with protection against dismounting:
120°
90°270°
240°
Fig. 4: Protection against dismounting
If the cam is in the 90°, 120°, 240° or 270° position on the outside of the fork, the centre plate is secured against
unauthorised dismounting.
Dismounting of the centre plate without a key is not possible in this case.
5 Operation
Important:
The key can only be inserted and removed in the 0° position.
Turn the key in the locking cylinder to the left or right to the following switching states.
Blind switches and push-buttons
The motors connected to the respective terminals run forward or backward depending on the switch position.
Depending on the design, 1 or 2 blind motors can be connected.
Up Motor runs forward.
Stop Motor is switched o󰀨.
Down Motor runs backward.
1-way switch, control push-button and other push-buttons
The devices connected to the respective terminals are switched on or o󰀨 according to the switch position.
On On
Centre (control push-button only) O󰀨
O󰀨 O󰀨


Product specificaties

Merk: Jung
Categorie: Niet gecategoriseerd
Model: CD 134.18 WU
Kleur van het product: Metallic
Ingebouwd display: Nee
Gewicht: - g
Soort: Drukknopschakelaar
Materiaal behuizing: Metaal
Internationale veiligheidscode (IP): IP44
Connectiviteitstechnologie: Bedraad
DC voltage bereik: - V
AC-ingangsspanning: 250 V
Aantal polen: 1P
Nominale stroom output: 10 A
AC voltage bereik: - V