JANDY XL 3 Handleiding

JANDY Heater XL 3

Lees hieronder de 📖 handleiding in het Nederlandse voor JANDY XL 3 (1 pagina's) in de categorie Heater. Deze handleiding was nuttig voor 14 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
D C
T
T
F
F
Thermostat
E971
115 VAC
Neutral
ON-OFF Switch
E782
E786
Twist Lock Plug
E784
Hi Limit
E771
E
F
Pressure
Switch
104089-02
G
White
Black
Black
Black
Orange
Yellow Yellow
Primary Control
N060
Transformer
N023
White Oil Pump
B A
Hi Limit
E722
Black
White
Black
Motor
N010
Ground
Current Flow
Wire Nut
Neutral
Cadmium Cell
N061
JANDY DP OIL FIRED POOL HEATER TROUBLESHOOTING
Check voltage at A
No
Yes
Check voltage at B
Check circuit breaker
No
Bad ON/OFF Switch (E782)
Yes
Check voltage at C
•Loose Twist Lock Plug
•Short in Wire Harness (R575)
•Bad Twist Lock Plug
No
Yes
Check voltage at D
No
Bad Hi Limit (E771)
No
Yes
Check voltage at E
•Loose Twist Lock Plug
•Short in Wire Harness (R575)
•Bad Twist Lock Plug
Check voltage at F
Yes
No
•Water flow problem
•Bad Pressure Switch
•Misadjusted Pressure Switch
•Blocked Siphon Loop Connection
Check voltage at G
Yes
No
Bad wire in Armored Cable (BX)
Heater Doesn’t Fire
Yes
Press RESET button on Primary Control Once
1) If unit fire and stays on, unit lost
prime to Oil Pump
2) If unit fires and goes out, or doesn’t
stay lit, or goes into RESET after 45
seconds …. this is a Oil Burner or
combustion problem
CALL QUALIFIED OIL SERVICE
If you press RESET on Primary Control, and
RESET button on Oil Burner Motor, and
nothing happens
1) Turn off power to heater, then
temporarily place a jumper from
T to T on the Primary Control and
turn power on. If unit fires, either the
Thermostat (E971) or the High
Limit (E722), or the Fireman’s Switch
has a problem.
2) If unit doesn’t fire, remove one of
the yellow wires from either terminal
marked F on the Primary Control.
If unit fires now, either:
Bad Cadmium Cell (N061)
Bad Primary Control, or
there is a fire in the
combustion chamber…. CALL
OIL SERVICE
Caution; Possible Electrocution: This circuit is high voltage, take extremely care when checking.
L0843, Rev A 09/05


Product specificaties

Merk: JANDY
Categorie: Heater
Model: XL 3

Heb je hulp nodig?

Als je hulp nodig hebt met JANDY XL 3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Heater JANDY

Handleiding Heater

Nieuwste handleidingen voor Heater