JANDY Hot Shot Handleiding

JANDY Heater Hot Shot

Bekijk gratis de handleiding van JANDY Hot Shot (2 pagina’s), behorend tot de categorie Heater. Deze gids werd als nuttig beoordeeld door 17 mensen en kreeg gemiddeld 4.0 sterren uit 8 reviews. Heb je een vraag over JANDY Hot Shot of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
Pressure
Switch
Thermistor
Pilot
Pilot
Generator
Fusible
Link
Hi-Limit
135°FHi-Limit
(150° F)
Gas Valve
Temperature Control
Orange
Red
SENSENPOTPOT
TH/PP
+
(PP)
Valve
(TH)
Red
Red
White
Black
TP/TH
TH
TP 1
2
Black
Black
3a 3b
4a
5a
BlacktoTH
Yel
low
toT
P
White to TP/TH
Red to TP
Laars
5b
Piezo Ignitor
Black
Pilot Coil
4b
Try to light the pilot.
Does pilot light?
Does pilot stay on
when gas valve
knob is released?
500+ mV @ PP
and PP-TH
terminals? (1)
1.Verify gas is on.
2.Check for air in gas line.
3.Is pilot tube clogged?
If voltage is found at one and not
the other, replace Fuse Link. Check
for Roll out, Soot, Downdrafting,
Low Gas Pressure, etc.
No
1.Check P/G output (1) .
2.Check for shorted wires.
3.Check pilot coil.
1.Check for low Pilot Generator
output.
2.Check for partial shorts
or loose wires.
3. Replace Pilot Generator.
500+ mV @
and both terminals
of Fuse Link? (2)
500+ mV @ Red
Wire of Pressure
Switch going to
rocker switch? (4b)
Perform Back Pressure Test. If
2.5 PSI or more, replace switch.
If less, check pump, filter, etc.
for pressure problem.
500+ mV @ Red wire
of from Hi-Limits to
Pressure Switch (4a)
1. Check each High Limit
individually. (3a&b)
2.Check if damage to
bypass or heat exchanger.
Set gas valve knob to pilot position.
Set rocker switch to OFF.
Set rocker switch to ON
Is there 200+ mV
@ Red wire of
Pressure Switch? (4b)
Yes
Is there 200+ mV
@ TH terminal of
the Gas Valve?
No
Is there 500+ mV
@ TH/PP on
Temp. Board?
Yes
Move rocker switch
to OFF. Rotate Gas
Valve Knob to ON.
Move rocker switch
to ON. Does heater fire?
Is there 500+ mV
@ Valve (TH) on
Temp. Board?
No
Yes
Yes
Is there 500+ mV
@ TH terminal of
Gas Valve?
Yes
Replace
Gas Valve
No
Yes
Yes
Yes
Yes
Yes
No
No
Check and/or replace
black wire from
Valve (TH) terminal
of Temp. Board and
TH terminal of Gas Valve.
No
Perform Thermistor Test, see below.
Replace Temp. Board
Check rocker
switch
Yes
No
Yes
No
No
No
No
No
Disconnect Pot wires and jump pot
terminals. If voltage drops to 200+ mV,
replace Temp. Control (P/N
R0058200).
Mat #0754, Rev. C 09/05