Bekijk gratis de handleiding van Intermatic WP2000 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.3 sterren uit 2 reviews. Heb je een vraag over Intermatic WP2000 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
WP2000 A REMOTE LOCATION MULTI-PURPOSE POST
This unit (weatherproof outlet box & cover) can be used outdoors or in wet locations
(protects receptacles and timers while in use for unattended applications). It is cCSAus Certified,
TYPE 3R rated and meets National Electrical Code requirements.
Contents
The following items are included:
•Weatherproofcover&housing
•Basecover
•Toggle,round,GFCIandduplexinserts
Installation Instructions
1. Determine number and size of PVC connections to be
made to the base of the Multi-Purpose post.
2. Use provided plugs to cap any entrance ports on the
base that will not be used ().DIAGRAM A
3. Use appropriate PVC reducers and secure to the base
where needed. ( for reducer orientation)DIAGRAM B
4. Secure any reducers and/or plugs with PVC glue.
5. Mount and secure base on PVC feeders with PVC glue.
6. Attach ground wire to ground bar ()DIAGRAM D
7. Attach Multi-Purpose post body to base using the four (4)
screws provided ()DIAGRAM C
Installation Instructions for use with wiring device only
8. Install selected wiring device to post according
to device manufacturer’s instructions.
9. Install selected insert over device (). Select the right insert for the application. If DIAGRAM E
you need to remove the knockouts on the round insert, grab them from the back with pliers
and pry down until they break free. Using round insert, knock out the appropriate hole size.
Installation Instructions for Optional Timer:
10.SelecttheIntermaticPB912M10RorPB313KTimer(DIAGRAM F)
11. Remove blank cover from top of Multi-Purpose post ()DIAGRAM F
12.FeedselectedtimerthroughopenbaseofMulti-Purposepostandmountusing
screws provided ()DIAGRAM F
13. Attach Multi-Purpose post body to base using the four (4) screws provided (DIAGRAM C)
14.Wireusinginstallationinstructionsprovidedwithtimer
Installations Instructions for Optional Photo Control
15.SelectanIntermaticK40seriesPhotoControl
16. Determine hole size needed for mounting ()DIAGRAM G
17. Locate drill pattern on back of Multi-Purpose post and drill required outlet
18. Mount Photo Control in outlet port.
19. Attach Multi-Purpose post body to base using the four (4) screws provided ()DIAGRAM C
20.WireaccordingtoinstallationinstructionsprovidedwithPhotoControl.
Installation Tips:
21. Optional Timer and/or Photo Controls should be mounted to Multi-Purpose post body prior
to mounting front device attaching body to bottom mounting plate.
22. Optional Timer and/or Photo Control wiring connections should be performed after
Multi-Purpose post body is attached to bottom mounting plate.
Limited One Year Warranty
If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This warranty is
extendedtotheoriginalhouseholdpurchaseronlyandisnottransferable.Thiswarrantydoesnotapplyto:(a)damagetounitscausedbyaccident,droppingorabuseinhandling,actsofGodoranynegligent
use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the product;
(e) sealed lamps and/or lamp bulbs, LED’s and batteries; (f) the finish on any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear; (g) transit damage, initial
installation costs, removal costs, or reinstallation costs.
INTERMATICINCORPORATEDWILLNOTBELIABLEFORINCIDENTALORCONSEQUENTIALDAMAGES.SOMESTATESDONOTALLOWTHEEXCLUSIONORLIMITATIONOFINCIDENTALOR
CONSEQUENTIALDAMAGES,SOTHEABOVELIMITATIONOREXCLUSIONMAYNOTAPPLYTOYOU.THISWARRANTYISINLIEUOFALLOTHEREXPRESSORIMPLIEDWARRANTIES.ALLIMPLIED
WARRANTIES,INCLUDINGTHEWARRANTYOFMERCHANTABILITYANDTHEWARRANTYOFFITNESSFORAPARTICULARPURPOSE,AREHEREBYMODIFIEDTOEXISTONLYASCONTAINEDINTHIS
LIMITEDWARRANTY,ANDSHALLBEOFTHESAMEDURATIONASTHEWARRANTYPERIODSTATEDABOVE.SOMESTATESDONOTALLOWLIMITATIONSONTHEDURATIONOFANIMPLIEDWARRANTY,
SOTHEABOVELIMITATIONMAYNOTAPPLYTOYOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with proof of purchase, postage prepaid to the authorized
servicecenterlistedbelow.Thiswarrantyismadeby:IntermaticIncorporated/AfterSalesService/7777WinnRd.,SpringGrove,Illinois60081-9698/815-675-7000http://www.intermatic.com Please be sure to
wrap the product securely to avoid shipping damage.
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
158WP12545
BASE
CAP UNUSED
HOLES WITH
PLUGS
DIAGRAM A
DIAGRAM E
DIAGRAM F
DIAGRAM G
1” PIPE
INSTALL
DIRECTLY
INTO
BASE
FIRST INSTALL
REDUCER BUSHING
INTO BASE INSTALL
1/2 PIPE TO STOP
1/2” PIPE
3/4” PIPE
FIRST INSTALL
REDUCER BREAK OFF
STOP AND INSTALL 3/4 PIPE
BREAK OFF STOP
BASE
1/2” PIPE STOP
DIAGRAM B
DIAGRAM C
SCREW (4)
HOUSING
BASE
KNOCKOUT REMOVAL
HOUSING
HOUSING
REMOVE
COVER
PB313EK TIMER
PB912M10R
TIMER
MOUNTING
SCREWS
DRILL HOLE
TO MOUNT
PHOTO CONTROL
K40XX
PHOTO CONTROL
DIAGRAM D
GROUND BAR
GROUND WIRE