Bekijk gratis de handleiding van Intermatic PF1222TB1 (4 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 24 mensen en kreeg gemiddeld 5.0 sterren uit 2 reviews. Heb je een vraag over Intermatic PF1222TB1 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/4

MODEL: PF1222TB1 SUBPANEL
TWO CIRCUIT POOL EQUIPMENT CONTROL WITH FREEZE AND HEATER PROTECTION
IN INDOOR/OUTDOOR ENCLOSURE
PANEL RATING: 60 AMP. 120/240 VOLT, 607 HZ.
This Pool Equipment Control is designed to automatically operate the Filter Pump, Cleaner Pump and also to provide
freeze protection for the pool equipment. Nevertheless this product is not intended to be a substitute for insulation,
coverings, or maintenance.
THE FILTER PUMP TIME SWITCH is located in the upper
left side of the enclosure and operates the Filter Pump, as
set by the trippers on the yellow dial, on a 24 hour
schedule. For setting the schedule, refer to page 3 of this
Manual.
THE FIREMAN SWITCH (heater protection mechanism) is
located next to the manual lever and its function is to stop
the heating process 20 minutes before the Time Switch
turns OFF the Filter Pump. By doing so, the circulating
water cools the heat exchanger thus preventing excess
heat build-up.
THE CLEANER PUMP TIME SWITCH is located in the
upper right side of the enclosure and operates the Cleaner
Pump (Booster Pump). The trippers of this Time Switch
should be set so that the operation of the Cleaner Pump
falls within the operation of the Filter Pump. To avoid
equipment damage, the two Time Switches are interlocked
and the Cleaner Pump would not operate unless the Filter
Pump is already operating.
THE FREEZE PROTECTION THERMOSTAT is located in
the lower left side of the enclosure and turns ON the Filter
Pump when the air temperature (where the Control Panel
is located) drops below the temperature set by the dial
(between 33˚F and 42˚F).
INSTALLATION
OPERATION &
SERVICE MANUAL
PF1000 SERIES
FREEZE PROTECTION CONTROLS
Risk of drowning!
Do not permit unsupervised children to use pool or spa.
Close supervision of children required at all times.
DANGER
Turn power off at main panel before servicing this switch or the equipment it controls. This control panel must be
installed according to the National Electrical Code and local code requirements. Use MIN 75˚C Copper conductors ONLY.
Install interchangeable circuit breakers with an interrupting current rating of 10000 symmetrical amperes, or higher.
Follow manufacturers instructions for installing and testing of ground fault circuit breakers (GFCB) and interrupters
(GFCI). Install only LISTED receptacle(s) and/or wiring device(s) inside the enclosure. When panel is outdoors, a LISTED
rainproof cover must be installed over the wiring device in the side knockouts. This control should not be connected
to any equipment which would cause bodily injury or property damage should it be activated unexpectedly.
Reinstall safety guard after wiring.
WARNING
Risk of Fire or Electrical Shock
GENERAL INFORMATION
Product specificaties
| Merk: | Intermatic |
| Categorie: | Niet gecategoriseerd |
| Model: | PF1222TB1 |
Heb je hulp nodig?
Als je hulp nodig hebt met Intermatic PF1222TB1 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Intermatic
16 November 2025
13 November 2025
13 November 2025
10 November 2025
8 November 2025
7 November 2025
7 November 2025
6 November 2025
6 November 2025
5 November 2025
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
9 Maart 2026
9 Maart 2026
9 Maart 2026
9 Maart 2026
9 Maart 2026
9 Maart 2026
9 Maart 2026
9 Maart 2026
9 Maart 2026
9 Maart 2026