INSTALLATION INSTRUCTIONS
1. Disconnect ALL power from the Mini-Wave Control Panel.
2. Remove the Deadfront Cover from the panel.
3. Remove the Low-Voltage Divider to gain access to the Relay Screws. (See Figure 1-1)
4. Remove the filler plate on the Low Voltage Divider by bending the plate back and forth until
the plate breaks off. (See Figure 1-1).
5. Remove the two screws and install the Relay (PA120) with the same two screws. (See Figure 1-1).
6. Plug the 24VAC coil wires from the relay to any of the two available three-pin plugs on the upper
control board. (See Figure 1-2).
7. Re-install the Low Voltage Divider in your Mini-Wave Control Panel. (See Figure 1-1).
8. Re-install Deadfront.
9. When installation is complete, button <3> on the Hand-Held Remote and Membrane Pad will
operate the pump.
INSTALLATION
INSTRUCTIONS
MODEL: PA120
24 VAC BOOSTER / CLEANER PUMP RELAY
POOL/SPA CONTROL
ACCESSORIES
Low Voltage
Divider
Filler Plate
PA120
Relay
120 VAC
Coil
Relay
Screws
Low Voltage
Divider
Filler Plate
PA120
Relay
120 VAC
Coil
Relay
Screws
Button <3>Button <3>
Upper Control
Board
24VAC Coil
Wires
Lower Control
Board
Upper Control
Board
24VAC Coil
Wires
Lower Control
Board
Figure 1-1
Figure 1-2
Figure 1-3
Product specificaties
| Merk: | Intermatic |
| Categorie: | Niet gecategoriseerd |
| Model: | PA120 |
Heb je hulp nodig?
Als je hulp nodig hebt met Intermatic PA120 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Intermatic
Intermatic MIL72ESWUZ-120 Handleiding Intermatic FM1D50E Handleiding Intermatic FM1D50A Handleiding Intermatic MIL72AQWUZ-120 Handleiding Intermatic IOS-DPBIF Handleiding Intermatic GMXFM1D50 Handleiding Intermatic IOS-DPBIMF Handleiding Intermatic IOS-DDR Handleiding