Intermatic OP2BK24 Handleiding
Intermatic Niet gecategoriseerd OP2BK24
Bekijk gratis de handleiding van Intermatic OP2BK24 (3 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 11 mensen en kreeg gemiddeld 5.0 sterren uit 2 reviews. Heb je een vraag over Intermatic OP2BK24 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/3

Libertyville, Illinois 60048
www.intermatic.com
Surface Mount Pedestals
OP5BK18, OP5GY18, OP5BK24, OP5GY24,
OP2BK18, OP2GY18, OP2BK24, OP2GY24
SAFETY SECTION
Warning
TO AVOID FIRE, SHOCK OR DEATH
• TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST POWER
BEFORE WIRING
Warning
TO BE INSTALLED AND/OR USED WITH ALL APPLICABLE LOCAL ELECTRICAL
CODES AND REGULATIONS.
Caution
SPLICES MUST BE MADE WITH PROPER SPLICING EQUIPMENT, MATERIALS
OR KITS
Caution
NO USER SERVICABLE COMPONENTS. DO NOT ATTEMPT TO SERVICE OR
REPAIR
Caution
USE COPPER CONDUCTORS ONLY
PRODUCT INSTALLATION
The Service Mount Pedestals are Type 3R Enclosure. At installation, do not fasten conduits, raceways or cables to the pedestal. Form “S”
loops with the cables and wires to prevent stress on the wires inside the enclosure. This ensures that the cables and wires have adequate
room to adjust for grade level changes caused by freeziing and thawing cycles, and soil subsidence. Ground wires are included with the
supply conductors, and can be used to provide the connection to the pedestal’s ground terminal. Single-Gang pedestals intended only
for use with cULus Listed (KCXS/7) GFCI receptacles rated at 20 A max. Double-Gang
pedestals are intended only for use with cULus Listed (KCXS/7) GFCI receptacles rated
at 20 A max., cULus Listed (RTRT/7) receptacles rated at 60 A max., or cULus Listed
(WFXV/7) switches rated at 60 A max.
Installed devices rated at 15-20 A must be weather-resistant (cover provides in-use
protection) and devices rated at 30-60 A must be water-tight.
The pedestals are also UL listed as mounting post. There are no knockout locations
provided. Mounting holes for fixtures or photocells must be drilled before installation.
When fixtures are mounted or raceways are extended from the top of the pedestal, a
conduit hub, sealing locknut, or sealing washer must be used.
These models can accommodate two 1-1/2” conduit raceways. There are four (7/16”)
holes on the pedestal base, which are secured to a concrete surface with the provided
hardware, anchors, washers and acorn nuts.
2.84
4.84
.44 4X
4.75
4.75
4.84
4.84
.44 4X
6.75
6.75
2.84
4.84
.44 4X
4.75
4.75
4.84
4.84
.44 4X
6.75
6.75
SCALE 1 : 2
SCALE 1 : 2
Single Gang Models
Base Measurement
Double Gang Models
Base Measurement
Wire Size (AWG) Copper OnlyTorque (lb - in.)
10-1420
825
4-635
TWO-YEAR LIMITED WARRANTY
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased or (b) completing a
warranty claim online at www.intermatic.com. This warranty is made by: Intermatic Incorporated, Customer Service 1950 Innovation Way,
Suite 300, Libertyville, IL 60048. For warranty service go to: http://www.Intermatic.com or call 815-675-7000.
Product specificaties
| Merk: | Intermatic |
| Categorie: | Niet gecategoriseerd |
| Model: | OP2BK24 |
Heb je hulp nodig?
Als je hulp nodig hebt met Intermatic OP2BK24 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Intermatic
16 November 2025
13 November 2025
13 November 2025
10 November 2025
8 November 2025
7 November 2025
7 November 2025
6 November 2025
6 November 2025
5 November 2025
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
22 Januari 2026
22 Januari 2026
22 Januari 2026
22 Januari 2026
22 Januari 2026
22 Januari 2026
22 Januari 2026
22 Januari 2026
22 Januari 2026
22 Januari 2026