Intel SRCU41L Handleiding

Intel Controller SRCU41L

Lees hieronder de đź“– handleiding in het Nederlandse voor Intel SRCU41L (24 pagina's) in de categorie Controller. Deze handleiding was nuttig voor 31 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/24
Intel® Raid Controller SRCU41L
User Manual
November 2004
Order Number: C89410-002
ii Intel® Raid Controller SRCU41L User Manual
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL ® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY
ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN
INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS
ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES
RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER
INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, life sustaining applications.
Intel may make changes to specifications and product descriptions at any time, without notice.
Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Intel reserves these for
future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them.
The Intel® Raid Controller SRCU41L may contain design defects or errors known as errata which may cause the product to deviate from published
specifications. Current characterized errata are available on request.
MPEG is an international standard for video compression/decompression promoted by ISO. Implementations of MPEG CODECs, or MPEG enabled
platforms may require licenses from various entities, including Intel Corporation.
This document and the software described in it are furnished copied in accordance with thunder license and may only be used or e terms of the
license. The information in this document is furnished for informational use only, is subject to change without notice, and should not be construed as a
commitment by Intel Corporation. Intel Corporation assumes no responsibility or liability for any errors or inaccuracies that may appear in this
document or any software that may be provided in association with this document. Except as permitted by such license, no part of this document may
be reproduced, stored in a retrieval system, or transmitted in any form or by any means without the express written consent of Intel Corporation.
Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order.
Copies of documents which have an ordering number and are referenced in this document, or other Intel literature may be obtained by calling
1-800-548-4725 or by visiting Intel's website at http://www.intel.com.
AlertVIEW, AnyPoint, AppChoice, BoardWatch, BunnyPeople, CablePort, Celeron, Chips, CT Connect, CT Media, Dialogic, DM3, EtherExpress,
ETOX, FlashFile, i386, i486, i960, iCOMP, InstantIP, Intel, Intel logo, Intel386, Intel486, Intel740, IntelDX2, IntelDX4, IntelSX2, Intel Create & Share,
Intel GigaBlade, Intel InBusiness, Intel Inside, Intel Inside logo, Intel NetBurst, Intel NetMerge, Intel NetStructure, Intel Play, Intel Play logo, Intel
SingleDriver, Intel SpeedStep, Intel StrataFlash, Intel TeamStation, Intel Xeon, Intel XScale, IPLink, Itanium, LANDesk, LanRover, MCS, MMX, MMX
logo, Optimizer logo, OverDrive, Paragon, PC Dads, PC Parents, PDCharm, Pentium, Pentium II Xeon, Pentium III Xeon, Performance at Your
Command, RemoteExpress, Shiva, SmartDie, Solutions960, Sound Mark, StorageExpress, The Computer Inside., The Journey Inside,
TokenExpress, Trillium, VoiceBrick, Vtune, and Xircom are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United
States and other countries.
*Other names and brands may be claimed as the property of others.
Copyright © Intel Corporation, 2004
Intel® Raid Controller SRCU41L User Manual iii
Contents
Contents
1 Overview.......................................................................................................................1
1.1 Overview....................................................................................................................................... 1
1.1.1 Operating System Support .............................................................................................. 2
1.2 Features........................................................................................................................................ 3
1.2.1 Drive Roaming................................................................................................................. 3
1.2.2 Drive Migration.................................................................................................................3
1.3 Hardware ......................................................................................................................................4
1.3.1 Intel® SRCU41L Raid Controller Features....................................................................... 4
2 Hardware Installation ...................................................................................................5
2.1 Requirements ............................................................................................................................... 5
2.2 Quick Installation .......................................................................................................................... 5
2.3 Detailed Installation ...................................................................................................................... 6
2.3.1 Resolving a Configuration Mismatch ............................................................................. 11
2.4 After You Have Installed the Storage Adapter............................................................................ 11
3 Storage Adapter Characteristics ................................................................................. 13
3.1 The Intel® Raid Controller SRCU41L Storage Adapter Overview .............................................. 13
3.1.1 Single-Channel Raid Controller ..................................................................................... 13
3.1.2 Decoding the Audible Alarm .......................................................................................... 15
3.2 Intel® Raid Controller SRCU41L Characteristics ........................................................................ 15
3.3 Technical Specifications ............................................................................................................. 15
3.3.1 Specifications................................................................................................................. 16
3.3.2 Array Performance Features ......................................................................................... 16
3.3.3 Fault Tolerance..............................................................................................................17
3.3.4 Electrical Characteristics ............................................................................................... 17
3.3.5 Thermal and Atmospheric Characteristics..................................................................... 17
3.3.6 Safety Characteristics .................................................................................................... 18
A Glossary of Terms and Abbreviations......................................................................... 19
Figures
1 Intel® Raid Controller SRCU41L Block Diagram .......................................................................... 2
2 Install the Battery Backup Unit...................................................................................................... 7
3 Inserting the Intel® SRCU41L Raid Controller in a PCI Slot ......................................................... 8
4 Terminating an Internal SCSI Disk Array.................................................................................... 10
5 Intel® Raid Controller SRCU41L Card Layout ............................................................................ 14
6 Glossary of Terms and Abbreviations.........................................................................................19


Product specificaties

Merk: Intel
Categorie: Controller
Model: SRCU41L
Breedte: 167 mm
Diepte: 58 mm
Frequentie van processor: 100 MHz
Intern geheugen: 64 MB
Type processor: Intel 80302
Temperatuur bij opslag: -40 - 60 °C
Compatibele besturingssystemen: Windows (2000, Server 2003, & XP), Red Hat Linux, SuSe Linux, Novell NetWare, SCO OpenServer, & \nUnixWare
Luchtvochtigheid bij opslag: 5 - 90 procent
Spanning: 5 V
Kloksnelheid geheugen: 66 MHz
Aantal kanalen: 1 kanalen
Ondersteunde opslagstationinterfaces: SCSI
Soorten RAID: 1, 5,10
Overdrachtssnelheid: 3 Gbit/s
Bedrijfstemperatuur (T-T): 0 - 55 °C
Relatieve vochtigheid in bedrijf (V-V): 5 - 90 procent
PCI Card form factor: Half-height (low-profile)
RAID Level Migratie: Ja
Online Capaciteit vergroting: Ja
SSD-ondersteuning: Nee

Heb je hulp nodig?

Als je hulp nodig hebt met Intel SRCU41L stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Controller Intel

Handleiding Controller

Nieuwste handleidingen voor Controller