Bekijk gratis de handleiding van IFM UGT582 (13 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 19 mensen en kreeg gemiddeld 5.0 sterren uit 10 reviews. Heb je een vraag over IFM UGT582 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/13
Operating instructions
Ultrasonic diffuse-reflection sensor
without IO-Link
UGT516
UGT517
UGT519
UGT520
UGT58x
UGT59x
80237716 / 01 02 / 2019
UK
2
1 Preliminary note
1.1 Symbols used
Instructions
> Reaction, result
[…] Designation of keys, buttons or indications
Cross-reference
Important note
Non-compliance may result in malfunction or interference.
Information
Supplementary note.
2 Safety instructions
Read this document before setting up the product and keep it during the entire
service life.
The product must be suitable for the corresponding applications and
environmental conditions without any restrictions.
Only use the product for its intended purpose .(→ 3 Functions and features)
If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
The manufacturer assumes no liability or warranty for any consequences
caused by tampering with the product or incorrect use by the operator.
Installation, electrical connection, set-up, operation and maintenance of the
product must be carried out by qualified personnel authorised by the machine
operator.
Protect units and cables against damage.
3 Functions and features
Ultrasonic sensor for monitoring levels and detecting objects.
3
UK
4 Installation
1
1
3
34
4
2
Secure the unit to a bracket.
1/2: status LEDs 1/2 (yellow),
setting aid and output indication
3: echo LED (green), is on when object or
background is detected
4: teach button
Sound-absorbing surfaces have a negative effect on a reliable function.
Technical data sheet): Consider the dead zone (
No object detection in the dead zone.
For units with metal housing (according to UL 508):
Observe a minimum distance of 12.7 mm between the sensor and non-
insulated live parts.
For further information please refer to www.ifm.com
→ General information about installation and operation.
5 Electrical connection
Disconnect power.
Connect unit (depending on the type selected):
BK: black
BN: brown
BU: blue
WH: white
BN
WH
BK
BU
4
1
3
2OUT2
L+
L
OUT1
• OUT1: switching output
• OUT2: analogue output
colours to DIN EN 60947-5-2


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: UGT582