IFM JN2200 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor IFM JN2200 (3 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 12 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/3
Installation instructions
Inclination sensor JN
JN2200
JN2201
80237500/00 04/2016
UK
2
1 Functions and features
The 2-axis analogue/binary inclination sensor with IO-Link interface enables angle
levelling and position detection of machines and installations.
Typical applications are, for example, the position detection of access platforms,
levelling of mobile cranes or monitoring of wind turbines.
2-axis inclination sensors with a measuring range of:
JN2200: ±180°
JN2201: ±45°
2 Symbols used
Instruction
Important note
Non-compliance may result in malfunction or interference.
3 Installation
Disconnect from power before installation.
3.1 Fixing
Fasten the device using 4 M5 screws on a flat surface.
Screw material: steel or stainless steel.
3.2 Mounting surface
The housing must not be exposed to any torsional forces or mechanical stress.
Use compensating elements if there is no flat mounting surface available.
4 Electrical connection
The unit must be connected by a qualified electrician.
The national and international regulations for the installation of electrical equipment
must be adhered to.
Disconnect the installation from power and connect the unit.
3
UK
The inclination sensors are fitted with two round 4-pole M12 connectors (class A)
in accordance with IEC 60947-5-2. The M12 connectors are mechanically A-coded
in accordance with IEC 61076-2-101.
 
1: L+ 24 V DC (+Ub-D)
2: OUT2 switching output 2
3: L- mass (GND)
4: OUT1 switching output 1 or IO-Link
M12 connector (left)
 
1: L+ 24 V DC (+Ub-A)
2: A2 analogue output 2
3: L- mass (GND)
4: A1 analogue output 1
M12 connector (right)
5 IO-Link
General information
This unit has an IO-Link communication interface (via pin 4) which requires an IO-
Link-capable module (IO-Link master) for operation.
The IO-Link interface enables direct access to process and diagnostic data.
Communication via a point-to-point connection is possible with USB adapter cable.
You will find the IODDs and parameter setting tools necessary for the configuration
of the IO-Link unit at www.ifm.com.
6 Technical data, approvals/standards
Detailed manuals, technical data, EC declaration of conformity, approvals and
further information can be found at www.ifm.com.
7 Maintenance, repair and disposal
The unit is maintenance-free.
Dispose of the unit in accordance with the national environmental regulations.


Product specificaties

Merk: IFM
Categorie: Niet gecategoriseerd
Model: JN2200

Heb je hulp nodig?

Als je hulp nodig hebt met IFM JN2200 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd IFM

IFM

IFM DP4302 Handleiding

12 April 2024
IFM

IFM EVCB02 Handleiding

11 Maart 2024
IFM

IFM EVCB03 Handleiding

11 Maart 2024
IFM

IFM EVF666 Handleiding

11 Maart 2024
IFM

IFM TM4599 Handleiding

8 Januari 2024
IFM

IFM ZB0074 Handleiding

8 Januari 2024
IFM

IFM EVF661 Handleiding

8 Januari 2024
IFM

IFM IIP201 Handleiding

7 Januari 2024
IFM

IFM DP4200 Handleiding

7 Januari 2024
IFM

IFM IIP200 Handleiding

7 Januari 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd