EL-GD10
Gas Detector
Important! Not made for carbon monoxide detection.
1
Introduction
Installation
For natural gas and town gas detection:
the ceiling (typically 0,3m below ceiling) at the room where gas leak can be expected and in a
place where air movements are not impeded by furniture or furnishing.
For LPG gas detection:
place where air movements are not impeded by furniture or furnishing.
Places where the detector should NOT be installed!
1. In an enclosed space (e.g. in cupboard or behind a curtain).
2. Directly above a sink.
3. Next to a door or window.
4. Next to an extractor fan.
5. In an area where the temperature may drop to 16°C or exceed +40°C.
6. Where dirt and dust may block the sensor.
7. In a damp or humid location.
Operation
Warm up state:
1. Plug-in the detector the “POWER” LED lights green and the alarm sounds “DiDi”, Alarm LED
2. , then the detector is ready
Attention!!
The detector should work according the above mentioned points otherwise it will not provide
the intended security. In that case do again the “Warming up” procedure. If there’s still no good
functioning the detector must be replaced.
Important! Not made for carbon monoxide detection.
Display gas
concentration
change
Gas sensor holes
Buzzer
“ ”“ ”
The EL-GD10 is a freestanding plug-in gas
detector for LPG, naturalgas. The detector
is made for indoor household use. When
the gas leak concentration reaches certain
preset levels the detector provides a visual
signal (LEDs and numeric display indicate
instant gas leak density) and a very strong
alarm tone. When the gas concentration
goes below these levels the detector
regresses to normal state automatically.
1
4
2
Gas leak alarm state
Gas concentration in a normal range
• Display “1,2,3” and “STATE” LED is green.
Gas concentration slightly high
• Display “3,4,5” the “STATE” LED is yellow and the alarm sounds slow “Di--Di”.
Gas concentration high
• Display “6,7,8,9” the “STATE” LED is yellow and the alarm sounds quick “DiDiDI--DiDiDi”.
Gas concentration reached preset Lower Explosive Level (3%~20%)
• Display “A”, “STATE” LED red, “ALARM” LED lights red and alarm sounds.
Maintenance
To keep the detector working properly, following is recommended:
1. Test the detector once a week e.g. press gently a lighter (without ignition) in front of the
detector close to the gas hole.
2. Keep the detector free of dust by gently vacuuming.
3. Don’t paint the detector.
4. Don’t spray aerosol on or near by the detector.
5. By refurbishing rooms store the detector in a poly bag.
Important! What to do when the alarm starts
Keep calm and carry out the following actions (not necessarily in the order given)
1.
2. Turn off all gas appliances.
3. Don’t switch on or off any electrical equipment including the El-GD10
4. Open doors and windows to increase ventilation.
5. Don’t use a telephone where the presence of gas is suspected.
If the alarm continues evacuate immediately the premises and contact the 24 hour
emergency service of the gas supplier.
• Detectable gases: LPG, natural gas and town gas
• Power supply: 100VAC - 240VAC ~ 50/60Hz
• Power consumption: < 4W
• Alarm level: 3%LEL~20%LEL
• Alarm volume: > 85dB
• Temperature range: -10°C ~ 50°C
• Relative humidity: < 97% RH
• Storage temperature: -25°C ~ 55°C
• Dimensions: 67 x 67 x 112mm
• Weight: 122g


Product specificaties

Merk: HQ
Categorie: Gasmelder
Model: EL-GD10
Kleur van het product: Wit
Gewicht: 122 g
Breedte: 67 mm
Diepte: 112 mm
Hoogte: 67 mm
Gewicht verpakking: 191 g
LED-indicatoren: Ja
Type verpakking: Doos
Afmetingen verpakking (BxDxH): 80 x 160 x 75 mm
Aantal per verpakking: 1 stuk(s)
Ingangsspanning: 220 - 240 V
Soort apparaat: Koker/Oven

Heb je hulp nodig?

Als je hulp nodig hebt met HQ EL-GD10 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden