Hotpoint G640X Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Hotpoint G640X (16 pagina's) in de categorie Fornuis. Deze handleiding was nuttig voor 39 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
HOB
G640N
G640T
G640W
G640X
Contents
Installation, 2-5
Positioning
Gas connection
Data plate
Burner and nozzle specifications
Electrical connection, 6
Description of the appliance, 7
Overall view
Start-up and use, 8
Practical advice on using the burners
Precautions and tips, 9
General safety
Disposal
Recycling & Disposal Information
Maintenance and care, 10
Switching the appliance off
Cleaning the appliance
Gas tap maintenance
Troubleshooting, 11
After Sales Service, 12
Guarantee, 13
Operating Instructions
English,1
GB
GB
GB
2
! Before operating your new appliance please read this
instruction booklet carefully. It contains important information
for safe use, installation and care of the appliance.
! Please keep these operating instructions for future
reference. Pass them on to possible new owners of the
appliance.
Positioning
! Keep packaging material out of the reach of children. It
can become a choking or suffocation hazard (see
Precautions and tips).
! The appliance must be installed by a qualified professional
according to the instructions provided. Incorrect installation
may cause harm to people and animals or may damage
property.
! This unit may be installed and used only in permanently
ventilated rooms in accordance with British Standard Codes
Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S. 6891
Current Editions. The following requirements must be
observed:
î‚• The room must be equipped with an air extraction system
that expels any combustion fumes. This may consist of a
hood or an electric fan that automatically starts each time
the appliance is switched on.
î‚• The room must also allow proper air circulation, as air is
needed for combustion to occur normally. The flow of air
must not be less than 2 m3/h per kW of installed power.
The air circulation system may
take air directly from the outside
by means of a pipe with an inner
cross section of at least 100 cm2;
the opening must not be
vulnerable to any type of
blockages.
The system can also provide the
air needed for combustion
indirectly, i.e. from adjacent rooms
fitted with air circulation tubes as
described above. However, these
rooms must not be communal
rooms, bedrooms or rooms that
may present a fire hazard.
î‚• Liquid petroleum gas sinks to the floor as it is heavier
than air. Therefore, rooms containing LPG cylinders must
also be equipped with vents to allow gas to escape in the
event of a leak. As a result LPG cylinders, whether
partially or completely full, must not be installed or stored
in rooms or storage areas that are below ground level
(cellars, etc.). It is advisable to keep only the cylinder
being used in the room, positioned so that it is not
subject to heat produced by external sources (ovens,
fireplaces, stoves, etc. ) which could raise the
temperature of the cylinder above 50°C.
Fitting the appliance
Gas and mixed hobs are manufactured with type X degree
protection against overheating. The following precautions
must be taken when installing the hob:
î‚• Kitchen cabinets adjacent to the appliance and taller
than the top of the hob must be at least 600 mm from the
edge of the hob.
î‚• Hoods must be installed according to their relative
installation instruction manuals and at a minimum
distance of 650 mm from the hob.
î‚• Place the wall cabinets adjacent to the hood at a
minimum height of 420 mm from the hob (see figure).
If the hob is installed beneath a
wall cabinet, the latter must be
situated at a minimum of 700 mm
above the hob (see figure).
î‚• The installation cavity should have the dimensions
indicated in the figure.
Fastening hooks are provided, allowing you to fasten the
hob to tops that are between 20 and 40 mm thick. To
ensure the hob is securely fastened to the top, we
recommend you use all the hooks provided.
555 mm
55 mm
475 mm
Hook fastening diagram
20
30
Hooking position Hooking position
for top H=20 mm for top H=30 mm
Installation
Enlarging the ventilation slot
between window and floor.
A j cd a ent
R moo
R moo to be
Vented
A
Examples of ventilation holes
for comburant air.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
Directly to
the utsideO
600mm min.
540mm min.
700mm min.
GB
3
Front
40
Hooking position Back
for top H=40 mm
! Use the hooks contained in the î‚“accessory packî‚”
î‚• Where the hob is not installed over a built-in oven, a
wooden panel must be installed as insulation. This must
be placed at a minimum distance of 20 mm from the
lower part of the hob.
Ventilation
To ensure adequate ventilation, the back panel of the
cabinet must be removed. It is advisable to install the oven
so that it rests on two strips of wood, or on a completely flat
surface with an opening of at least 45 x 560 mm (see
diagrams).
Where a hob is installed above an oven without a
forced ventilation cooling system, adequate ventilation
must be provided inside the cabinet by means of air
holes through which air can pass (see figure).
Gas connection
The appliance should be connected to the main gas supply
or to a gas cylinder in compliance with current national
regulations. Before carrying out the connection, make sure
the cooker is compatible with the gas supply you wish to
use. If this is not the case, follow the instructions indicated in
the paragraph î‚“Adapting to different types of gas.î‚”
When using liquid gas from a cylinder, install a pressure
regulator which complies with current national regulations.
! Check that the pressure of the gas supply is consistent
with the values indicated in Table 1 (î‚“Burner and nozzle
specificationsî‚”). This will ensure the safe operation and
longevity of your appliance while maintaining efficient
energy consumption.
Connection with a rigid pipe (copper or steel)
! Connection to the gas system must be carried out in such
a way as not to place any strain of any kind on the
appliance.
There is an adjustable -shaped pipe fitting on theL
appliance supply ramp and this is fitted with a seal in order
to prevent leaks. The seal must always be replaced after
rotating the pipe fitting (seal provided with appliance). The
gas supply pipe fitting is a threaded 1/2 gas cylindrical male
attachment.
Connecting a flexible jointless stainless steel pipe to a
threaded attachment
The gas supply pipe fitting is a threaded 1/2 gas cylindrical
male attachment.
These pipes must be installed so that they are never longer
than 2000 mm when fully extended. Once connection has
been carried out, make sure that the flexible metal pipe
does not touch any moving parts and is not compressed.
! Only use pipes and seals that comply with current national
regulations.
Checking the tightness of the connection
! When the installation process is complete, check the pipe
fittings for leaks using a soapy solution. Never use a flame.
Adapting to different types of gas
To adapt the hob to a different type of gas other than default
type (indicated on the rating plate at the base of the hob or
on the packaging), the burner nozzles should be replaced
as follows:
1. Remove the hob grids and slide the burners off their
seats.
2. Unscrew the nozzles using a 7 mm socket spanner, and
replace them with nozzles for the new type of gas (see
table 1 î‚“Burner and nozzle characteristicsî‚”).
3. Reassemble the parts following the above procedure in
the reverse order.
4. Once this procedure is finished, replace the old rating
sticker with one indicating the new type of gas used.
Sticker are available from any of our Service Centres.
î‚• Adjusting the burnersî‚’ primary air :
Does not require adjusting.
560 mm.
45 mm.


Product specificaties

Merk: Hotpoint
Categorie: Fornuis
Model: G640X
Apparaatplaatsing: Ingebouwd
Soort bediening: Draaiknop
Breedte: 580 mm
Hoogte: 510 mm
Soort materiaal (bovenkant): Keramisch
Vermogen brander/kookzone 2: 1900 W
Vermogen brander/kookzone 3: 1900 W
Vermogen brander/kookzone 1: 3000 W
Aantal branders/kookzones: 4 zone(s)
Type kookplaat: Gaskookplaat
Electronische ontsteking: Ja
Type brander/kookzone 1: Groot
Type brander/kookzone 2: Regulier
Type brander/kookzone 3: Regulier
Aantal gaspitten: 4 zone(s)
Aantal elektronische kook zones: 0 zone(s)
Veiligheidsklep: Nee
Type brander/kookzone 4: Sudderen
Vermogen brander/kookzone 4: 1000 W
Voedingsbron brander/kookzone 1: Gas
Voedingsbron brander/kookzone 2: Gas
Voedingsbron brander/kookzone 3: Gas
Voedingsbron brander/kookzone 4: Gas
Positie brander/kookzone 1: Links voor
Diameter brander/kookzone 1: 100 mm
Positie brander/kookzone 2: Links achter
Diameter brander/kookzone 2: 75 mm
Positie brander/kookzone 3: Rechts achter
Diameter brander/kookzone 3: 75 mm
Positie brander/kookzone 4: Rechts voor
Diameter brander/kookzone 4: 55 mm
Kookzone 1 vorm: Rond
Kookzone 2 vorm: Rond
Kookzone 3 vorm: Rond
Kookzone 4 vorm: Rond

Heb je hulp nodig?

Als je hulp nodig hebt met Hotpoint G640X stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Fornuis Hotpoint

Handleiding Fornuis

Nieuwste handleidingen voor Fornuis