Honeywell TH9320WF5003/U Handleiding

Honeywell Thermostaat TH9320WF5003/U

Lees hieronder de đź“– handleiding in het Nederlandse voor Honeywell TH9320WF5003/U (36 pagina's) in de categorie Thermostaat. Deze handleiding was nuttig voor 41 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/36
® U.S. Registered Trademark. Patents
pending. Copyright © 2019 Resideo.
All rights reserved.
69-2815EFS-07
Smart Thermostat 9000
Color Touchscreen
TH9320WF
Installation Guide
72Âş
SET TO
72
Âş
HOME FAN SYSTEM MENU
Fri, Jun 14, 2013
6:30 pm
INDOOR
45% Humidity
OUTDOOR
S USTAT
cool mode
80 /55% ËšHumidity
following schedule
Connected by
the TCC app
72
°
HOME. Touch to display Home screen.
FAN. Select fan mode.
SYSTEM. Select system mode (heat/cool).
MENU. Touch to display options. Start here
to set a program schedule.
Current schedule. Change temperature
setting and select temporary or permanent
hold.
Indoor conditions. Shows indoor
temperature and humidity.
Current date and time.
Current status. Shows system mode (heat/
cool).
Outdoor conditions. Outdoor temperature
and humidity appear after registration.
69-2815EFS—07 2
LEVEL
HERE
M34819
C
K
Rc
R
W-
O/B
Y
G
W2-
Aux/E
Y2
L
M34500A
Read and save these instructions
Wallplate installation
1. Separate wallplate from thermostat.
2. Mount wallplate as shown below.
Drill 3/16" holes for drywall. Drill 7/32" holes for plaster.
Wall anchors
Wallplate
Wire hole
Mounting screws
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before
beginning installation.
MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube,
do not place the old control in the trash.
Wallplate
Back of
Thermostat
3 69-2815EFS—07
CCommon wire from secondary side of cooling transformer (if 2 transformers).
KOptional C-wire adaptor.
Rc Cooling power. Connect to secondary side of cooling system transformer.
RHeating power. Connect to secondary side of heating system transformer.
W-O/B 1st stage heat relay. Or changeover valve for heat pumps.
Y1st stage compressor contactor.
GFan relay.
W2-Aux/E 2nd stage heat relay. Or heat pump auxiliary/Emergency heat relay.
Y2 2nd stage compressor contactor.
LHeat pump system monitor.
Jumper Loop, a plug with a wire loop used to connect the to the terminals, R Rc
Leave jumper loop in place in single transformer systems. Remove (unplug)
jumper loop in two transformer systems.
Terminal Designations
Wiring
C
K
Rc
R
W-
O/B
Y
G
W2-
Aux/E
Y2
L
Remove
jumper loop
ONLY if you
have both
R and Rc
wires.
Terminal
release
Terminal
holes
accept one
wire


Product specificaties

Merk: Honeywell
Categorie: Thermostaat
Model: TH9320WF5003/U

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell TH9320WF5003/U stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermostaat Honeywell

Handleiding Thermostaat

Nieuwste handleidingen voor Thermostaat