Bekijk gratis de handleiding van EBERLE FIT 3Rw (2 pagina’s), behorend tot de categorie Thermostaat. Deze gids werd als nuttig beoordeeld door 3 mensen en kreeg gemiddeld 4.8 sterren uit 7 reviews. Heb je een vraag over EBERLE FIT 3Rw of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

User and
installation guide
Room Temperature Controller FIT 3Rw
(with change over contact)
468931004 122
G
1 Principle of operation
The programmable room temperature controller FIT 3Rw allows
programming switching events (up to 9) and temper atures
according to personal needs. After installation the device auto-
matically shows the time of day and the room temperature. In
AUTO mode, the Heater (Cooler) will be automatically activated
according to programmed time and temperature. Program 1 is
the default pre-set program (see 8.). The room temperature will
be controlled according to the temperature measured by the
internal or remote sensor. The Heater will be switched on when
the temperature drops below the current set-point.
2 Installation
Caution!
This device must be installed by a qualied electrician,
according to the wiring diagram on the device and in com-
pliance with all applicable safety regulations.
Appropriate installation measures must be taken to achieve
the requirements of protection class II.
This device, is used to control the temperature only in dry
rooms, under normal environmental conditions. This elec-
tronic device conforms to EN 60730, It is an “independently
mounted control” and works according to operating prin-
ciple 1C.
3 Use
The electronic Room Temperature Controller FIT 3Rw can be
used to control the room temperature in conjunction with:
• Thermal actuators for e.g. water based oor heating or
convector heaters
• Oil or Gas heaters
• Circulation pumps
• Heatpumps
• Underoor heating with heat / cool change over
4 Features
• One line text display for simplied operation
• Back light
• Real time clock (setting of year, month, day, time)
• Automatic Summer- Winter time change over
• Max 9 events per day (each day independently)
• Pre-set and adjustable programs
• Optimum-Start
• Arm chair programming (with display unit removed)
• Holiday-Mode (date from – until can be set)
• Timer (Party) specic temperature for congurable duration
• Relay change over contact (for uses in conjuction with
connection strip EV 230 H/K...)
• Range limits for adjusting max and min temperature
• Access protection
• Operating language can be selected
• Control mode PWM or ON/OFF
• Minimum output on/o time and hysteresis congurable for
ON/OFF control
• Valve protection
• Adaptation to valves normally open or normally closed
• Measures the room temperature with the internal sensor or a
remote sensor
Electric connection
Caution: disconnect electric circuit from supply
Connecting according to Wiring Diagram
For exible or solid wires 1 - 2,5mm
2
Remote sensor F 190 021 (as accessory)
8. Pre-set programs
There are 3 pre-set time/temperature programs in the control-
ler. Pre-set program 1 (as shown below) is the default. Therefore,
if pre-set program 1 is the best program to suit the application,
there will be no need to change the time/temperature settings
on the device.
To select another program see 9. G1.
Program 1
Monday to Friday
Events123465
Time6:008:3012:0014:0017:0022:00
Temperature °C21,018,021,018,021,015,0
Saturday and Sunday
Events123465
Time7:0010:0012:0014:0017:00
23:00/22:00*
Temperature °C21,018,021,02121,015,0
6:00 h8:00 h10:00 h12:00 h14:00 h16:00 h18:00 h20:00 h22:00 h
Mon – Fri
Sat – Sun
*23:00/22:00 = 23:00 for Saturday
Program 2
Monday to Friday
Event123465
Time6:008:3012:0014:0017:0022:00
Temperature °C21,018,021,018,021,015,0
Saturday and Sunday
Event12
Time7:00
23:00/22:00*
Temperature °C21,015,0
6:00 h8:00 h10:00 h12:00 h14:00 h16:00 h18:00 h20:00 h22:00 h
Mon – Fri
Sat – Sun
*23:00/22:00 = 23:00 for Saturday
Program 3
Monday to Friday
Events1234
Time6:008:3017:0022:00
Temperature °C21,018,021,015,0
Saturday and Sunday
Events1234
Time7:0010:0012:00
23:00/22:00*
Temperature °C21,018,021,015,0
6:00 h8:00 h10:00 h12:00 h14:00 h16:00 h18:00 h20:00 h22:00 h
Mon – Fri
Sat – Sun
*23:00/22:00 = 23:00 for Saturday
Notes for Programming
• Activated settings terminate automatically 3 Min after the last
key press, without saving. They return to the mode which was
active before entering the settings, e.g. AUTO, MAN, etc.
• Entering a Code: change value with + – key then press OK
• When going through User- or Installer settings the item num-
ber used in the manual will be displayed, e.g. G1 for „Program
select one“ or H2 for „Control Mode“.
• There may be gaps in the sequence of menu numbers.
Troubleshooting
1. It is getting warm too late:
a. Are clock and program events set correctly?
b. Is the Optimum Start feature switched on? see H7
Did the controller have enough time (several days) to adapt
to the room’s characteristics?
c. Is an automatic change between Summer- and Winter time
activated, see G5
2. The controller does not accept any changes
Is access protection switched on? see G6
3. The range of temperature setting is limited.
Are temperature limits set? See G7
4. Temperature display doesn‘t change.
Is display of set-temperature activated? See G10
Connecting the remote sensor
F 193 720 or F190 021 (optional)
In order to measure the room temperature, instead of the inter-
nal sensor an external one can be used.
Remote or internal sensor selection can be made via menu
item H1.
Lay sensor inside a protective tube (simplies replacement).
The sensor lead can be extended up to 50 m by using a cable
and connections suitable for 230 V. Avoid laying sensor cable
alongside power cables, for example inside a conduit.
Caution!
The sensor is at mains voltage.
6 Technical Data
Order TypeFIT 3Rw
Supply voltage230 V AC 50 HZ (195…253 V)
Temperature setting range5 °C ... 30 °C; in 0,5 °C steps
Temperature resolution 0,1 °C steps
OutputRelay change over contact
Switching current
Heating
Cooling
10mA ... 5(2)A AC; 230 V~
10mA ... 1(1) A AC, 230V~
Output signal
PWM
(Pulse Width modulation)
or ON/OFF
PWM cycle timeadjustable
Hysteresis adjustable (ON/OFF only)
Minimum programmable time10 Min
Power consumption ~ 1,2 W
Accuracy of clock< 4 Min / year
Power reserve~ 10 Years
Remote sensor (optional)
F 193 720, length 4 m,
F 190 021.
Both can be extended up to
50 m.
Ambient temperature
Operating
Storage
without condensation
0 °C … 40 °C
–20 °C … 70 °C
Rated impulse voltage 4 kV
Ball pressure test75 ± 2 °C
Voltage and Current for
the purposes of
Interference measurements
230 V, 0,1 A
Degree of protection IP 30
Protection class of housingII (see Caution)
Pollution degree2
Software classA
Weight~ 100 g
Energy classIV = 2 %
(acc. EU 811/2013, 812/2013, 813/2013, 814/2013)
7 Wiring Diagram / Dimensions
Sensor
N
L
N
L
230V~50Hz
Remote sensor F 193 720 (as accessory)
20
Ø7,8
Actual Day
Actual
Room
Temperature
Helping text
Mode = AUTO
Time = 14:31
Caution!
Maximum length
of removed cable
insulation 8 mm.
The controller should be mounted at a location in the room
which:
• can be easily accessed
• is free of curtains, cabinets, shelves, etc.
• allows free air circulation
• is not exposed to direct sunlight
• is not draughty (when doors or windows are opened)
• is not directly inuenced by the source of heat/cooling
• is not located on an outer wall
• is approx. 1.5 m above the oor.
Fitting
in a conduit box Ø 60 mm
• remove the display unit
• remove the frame
• Mount it following the reverse
procedure
Caution!
Mounting in plastic wall boxes only
To insert or remove a exible wire press pin.
The plastic tab must be in place to provide insulation between
the terminals/wires and the mounting screw.
5. Mounting
Product specificaties
| Merk: | EBERLE |
| Categorie: | Thermostaat |
| Model: | FIT 3Rw |
Heb je hulp nodig?
Als je hulp nodig hebt met EBERLE FIT 3Rw stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Thermostaat EBERLE
8 Mei 2026
6 September 2024
6 September 2024
6 September 2024
8 Februari 2024
17 Januari 2024
17 Januari 2024
22 Augustus 2023
22 Augustus 2023
22 Augustus 2023
Handleiding Thermostaat
Nieuwste handleidingen voor Thermostaat
7 Mei 2026
2 Mei 2026
1 Mei 2026
30 April 2026
28 April 2026
28 April 2026
28 April 2026
6 April 2026
1 April 2026
1 April 2026