Honeywell RPLS531A1003 Handleiding

Honeywell Schakelaar RPLS531A1003

Lees hieronder de 📖 handleiding in het Nederlandse voor Honeywell RPLS531A1003 (6 pagina's) in de categorie Schakelaar. Deze handleiding was nuttig voor 25 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
RPLS530A/RPLS531A 1/6
The RPLS530A/RPLS531A switch can be used in a single-pole or 3-way
installation with the following types of lighting:
• Incandescent
• Halogen
• Low-voltage halogen with transformer
• Fluorescent
The
RPLS530A/RPLS531A
switch cannot be used with a load below 40
W, a load above 500 W or a motor.
Cut power at the circuit breaker to avoid electric shock.
Remove the existing switch. (For a 3-way installation, identify and
label the wire that is connected to the “common” screw.)
Install the new switch (refer to the appropriate section below).
Apply power at the circuit breaker.
SINGLE-POLE INSTALLATION
Connect wires "2" and "C" of the RPLS530A/RPLS531A to the line
(120 V) wire.
EXISTING 3-WAY INSTALLATION
Connect wire "C" of the RPLS530A/RPLS531A to the "common" wire,
identified when removing the old switch. Connect the other two
RPLS530A/RPLS531A wires to the two remaining wires.
At the other 3-way switch, connect the jumper wire between the "com-
mon" screw and the screw where wire "1" of the RPLS530A/RPLS531A
is connected.
NEW 3-WAY INSTALLATION
The jumper wire is not required in this installation. A single-pole switch
can be used as the other switch in a 3-way installation.
Pry the switch door open from the
bottom using a small screwdriver.
Ensure the ON/OFF selector is set to
ON.
Reset the switch using a paper clip.
0:00 and MO will flash.
If the display is blank:
Ensure the ON/OFF selector is prop-
erly engaged in the ON position. Push it to the right using a small
screwdriver.
If the programmable switch controls a lamp equipped with a built-in
On/Off switch, ensure the lamp switch is set to On.
Ensure the light bulb is not burned out and is tightly screwed in its socket.
EXISTING 3-WAY INSTALLATION
If either switch does not work properly, rewire the jumper between the
"common" screw and the other screw.
WARNING: Before replacing the light bulb, place the ON/OFF selector in
the OFF position. Failure to do so might damage the switch.
NOTE: The switch displays the time in 24-hour format by default or fol-
lowing a reset.
To change to 12-hour format (or vice versa), proceed as follows:
a) Press one of the control buttons to ensure the MAN or AUTO
indicator is displayed.
b) Press the MIN and HOUR buttons simultaneously and brieftly
(0:00 display = 24-hour, 12:00 display = 12-hour).
Set the time using the HOUR and MIN buttons. If you have selected
the 12-hour format, ensure that PM appears on the screen when an
afternoon time is displayed.
Set the day by using the DAY button.
Press one of the control buttons or close the switch door to return to
normal operation.
1.
2.
M38935
Line
Neutral
See NOTE A
120 VAC
Line
Neutral
120 VAC
M38936
Red
120 VAC
Jumper Red 3-wire cable
See NOTE A
3.
4.
M38937
120 VAC See NOTE A
M38934
Control (4)
Reset
On/Off selector
RPLS530A/RPLS531A 2/6
The programmable switch has 2 operating modes: manual (MAN) and
automatic (AUTO).
To switch mode, press the switch door for 3 seconds.
Manual Mode
The programmable switch operates as a regular switch.
Briefly press the switch door to turn the lights On or Off.
The mode (MAN) and state (ON or OFF) are displayed.
Automatic Mode
The programmable switch follows the programmed
schedule. The mode (AUTO), state (ON or OFF) and
current program number are displayed.
To temporarily override the programmed schedule, press the switch door.
The new state ( or ON OFF) will flash to show that this state is temporary.
The override remains in effect until you press the switch door again or
until the beginning of the next program.
You can set up to 7 programs. To set a program, you need to enter its
start time (ON) and its end time (OFF).
Pry the switch door open using a small screwdriver.
Press the PGM button to display a program and its
On or Off time. For example, when you first press
PGM, program number 1 (P1) and its On time
(ON) will appear. - : - - will appear instead of the
time if the program is not set (inactive).
Press the DAY button to select the day to which
you want to apply the program.
NOTE: If you want to apply the program to every
day of the week, press DAY until all the days are
displayed. (This still counts as 1 program, not 7)
Press the HOUR and MIN buttons to set the ON time (time when
you want the lights to turn on). If you have selected the 12-hour
format, ensure that PM appears on the screen when an afternoon
time is displayed.
After you have programmed the ON time, press the PGM button to
display the OFF time (time when you want the lights to turn off).
Repeat steps 3 through 5 to program the OFF
time. If the program ON time is set for every day of
the week, the program OFF time will automatically
be set for every day.
To set another program, repeat steps 2 through 6.
Programs that are not set will remain inactive.
Press one of the control buttons or close the switch door to return to
normal operation.
Clearing a Program
Press the PGM button until the desired program is selected. Hold the
PGM button for 3 seconds. -:-- appears when the program is erased.
Supply: 120 VAC, 50 / 60 Hz
Minimum load: 40 watts
Maximum load: 500 watts
Operating temperature range: 5°F to 122°F (-15°C to 50°C)
Storage temperature range: -4°F to 122°F (-20°C to 50°C)
Power outage: The programs are protected by a rechargeable battery.
The screen is blank during the power outage.
Certifications: CSA & UL
Resideo warrants this product, excluding battery, to be free from defects in work-
manship or materials, under normal use and service, for a period of one (1) year
from the date of first purchase by the original purchaser. If at any time during the
warranty period the product is determined to be defective due to workmanship or
materials, Resideo shall repair or replace it (at Resideo’s option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the place from
which you purchased it; or
(ii) call Resideo Customer Care at 1-800-468-1502. Customer Care will make the
determination whether the product should be returned to the following address:
Resideo Return Goods, 1985 Douglas Dr. N., Golden Valley, MN 55422, or whether
a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall
not apply if it is shown by Resideo that the defect was caused by damage which
occurred while the product was in the possession of a consumer.
Resideo’s sole responsibility shall be to repair or replace the product within the
terms stated above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR
DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF
ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS
PRODUCT.
Some states do not allow the exclusion or limitation of incidental or consequential
damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDEO MAKES ON
THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING
THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICU-
LAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS
WARRANTY. Some states do not allow limitations on how long an implied warranty
lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which
vary from state to state. If you have any questions concerning this warranty, please
write Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422 or call
1-800-468-1502.
If you have any questions about your light switch, go to
http://honeywellhome.com, or call Customer Care toll-free at
1-800-468-1502.
5.
6.
7.
M38499
M38500
M38501
8.
Blank display • Verify circuit breaker at main panel.
• Verify if light bulb is burned out
• Ensure the ON/OFF selector is at ON.
• Reset the switch using a paper clip.
Faded or irregular
display
• Load is less than 40 W
• Ambient temperature is below freezing
point
Cannot switch between
24-hour format and
12-hour format
First, press one of the control buttons so
that MAN or AUTO appears on display.
Programs do not run as
expected
• Make sure the switch is properly pro-
grammed.
• Note that -:-- indicates an inactive pro-
gram, 00:00 indicates midnight.
• If the switch has been configured for
12-hour format, check that PM appears on
the left side of the screen when an after-
noon time is displayed.
The metal plate is hot This is normal with high loads (maximum of
500 W).
9.
10.
RPLS530A/RPLS531A 3/6
L’interrupteur RPLS530A/RPLS531A peut être utilisé aussi bien pour une
installation unipolaire que pour une installation à 3 voies avec les types
d’éclairage suivants :
• Incandescent
• Halogène
• Halogène basse tension avec transformateur
• Fluorescent
Le RPLS530A/RPLS531A ne peut être utilisé avec une charge infé-
rieure à 40 W , une charge supérieure à 500 W ou un moteur.
Mettre le circuit hors tension à partir du disjoncteur afin d'éviter tout
risque de choc électrique.
Enlever l’interrupteur existant (pour une installation à 3 voies, identi-
fier et marquer le fil relié à la borne «commun»).
Installer le nouvel interrupteur (voir la section appropriée ci-des-
sous).
Remettre le circuit sous tension à partir du disjoncteur.
INSTALLATION UNIPOLAIRE
Relier les fils «2» et «C» du RPLS530A/RPLS531A à la ligne 120 Vca.
INSTALLATION EXISTANTE À 3 VOIES
Relier le fil «C» du RPLS530A/RPLS531A au fil «commun» que vous
avez identifié lorsque vous avez enlevé l’ancien interrupteur. Relier les
deux autres fils du RPLS530A/RPLS531A aux deux fils restants.
Pour l’autre interrupteur à 3 voies, relier le fil de raccord (fourni) entre la
borne «commun» et la borne sur laquelle le fil « du RPLS530A/RPLS531A
est branché.
NOUVELLE INSTALLATION À 3 VOIES
Le fil de raccord n’est pas requis dans cette installation. Dans le cas
d’une installation à 3 voies, l’autre interrupteur peut être un interrupteur
unipolaire.
Soulevez le bas du couvercle de
l’interrupteur à l’aide d’un petit
tournevis.
S’assurer que le sélecteur ON/
OFF ON est placé à .
Réinitialiser l’interrupteur à
l’aide d’un trombone. 0:00
clignotera à l’écran.
Si rien n’est affiché à l’écran :
S’assurer que le sélecteur ON/OFF est bien mis à la position ON. Le
placer bien à droite à l’aide d’un petit tournevis.
Si l’interrupteur commande une lampe munie d’un interrupteur inté-
gré, placer son interrupteur à «Marche» (On).
S’assurer que l’ampoule n’est pas brûlée et est bien vissée.
INSTALLATION EXISTANTE À 3 VOIES
Si l’un ou l’autre des interrupteurs ne fonctionne pas, rebrancher le fil de
raccord entre la borne «commun» et l’autre borne.
MISE EN GARDE : Avant de remplacer l'ampoule, placer le sélecteur
ON/OFF (marche/arrêt) à la position OFF, faute de quoi l’interrupteur
risque d’être endommagé.
NOTA : L’interrupteur affiche l’heure en format 24 heures par défaut ou
après une réinitialisation.
Pour basculer entre le format 12 heures et le format 24 heures, pro-
céder comme suit :
a) Appuyer sur l’une des touches de contrôle afin de s’assurer que
l’indicateur MAN ou AUTO est affiché.
b) Appuyer simultanément et brièvement sur les touches
MIN
et
HOUR
(affichage
0:00
= 24 heures; affichage
12:00
= 12
heures).
Régler l’heure à l’aide des touches HOUR et MIN. Si le format 12
heures est sélectionné, s’assurer que apparaît lorsque l’heure PM
de l’après-midi est affichée.
Régler le jour à l’aide de la touche DAY.
Appuyer sur une touche de contrôle ou replacer le couvercle de
l’interrupteur.
1.
2.
M38935
120 Vca
Voir la NOTE A
neutre
ligne
neutre
ligne
120 Vca
M38936
120 Vca Voir la NOTE A rouge
câble trifilaire
rouge
raccord
3.
4.
M38937
120 Vca Voir la NOTE A
M38934
réinitialisation
touche de contrôle (4)
sélecteur On/Off


Product specificaties

Merk: Honeywell
Categorie: Schakelaar
Model: RPLS531A1003

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell RPLS531A1003 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Schakelaar Honeywell

Handleiding Schakelaar

Nieuwste handleidingen voor Schakelaar