Honeywell HUL570 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Honeywell HUL570 (28 pagina's) in de categorie Luchtbevochtiger. Deze handleiding was nuttig voor 49 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/28
GETTING TO KNOW
YOUR COOL MIST
HUMIDFIER
Visible cool mist
With ultrasonic humidification,
a nebulizer vibrates at
ultrasonic frequency, breaking
water droplets into fine mist
Be careful not to over-humidify: Exceeding a
60% humidity level can cause condensation
around unit, on walls and on surfaces; if this
occurs, open a door and turn the humidifier
off or to a lower setting
Instruction Manual
HONEYWELL TOP FILL
COOL MIST HUMIDIFIER
MODEL HUL570 SERIES
Humidity Level
• The ideal indoor humidity level is 40-60%
Use a Honeywell Humidity Monitor
(not included) to check your indoor
humidity level
Demineralization Cartridge
A demineralization cartridge, designed to
fit in this humidifier, is available to help
reduce white dust in areas with hard water.
Save these instructions for future reference.
Visit www.HoneywellPluggedIn.com
or call 800-477-0457 for questions and
information about this humidifier
2
GETTING TO KNOW YOUR HUMIDI
IMPORTANT SAFETY
INSTRUCTIONS
READ AND SAVE THESE SAFETY
INSTRUCTIONS BEFORE USING
THIS HUMIDIFIER
When using electrical appliances, basic
precautions should always be followed to
reduce the risk of fire, electrical shock and
injury to people, including the following:
1. The humidifier should always be placed on a
firm, flat, waterproof surface at least four feet
(1.2m) away from bedside, 12 inches (30 cm)
from the wall and out of reach of patients,
children and pets. Be sure the humidifier is in
a stable position and the power cord is away
from heated surfaces and out of the way to
prevent the humidifier from being tipped over.
2. The humidifier should not be left unattended
in a closed room since air could become
saturated and leave condensation in front
of unit, on walls and furniture. Leave room
door partly open. aim Mist Outlet Do not
directly at children, walls or furniture.
3. Before using the humidifier, extend the cord
and inspect for any signs of damage. Do not
use the unit if the cord has been damaged.
Do not operate with power cord coiled or with
twist tie in place.
4. The humidifier has a polarized plug (one blade
is wider than the other) as a safety feature.
This plug will fit into a polarized outlet only
one way. If the plug does not fit fully into the
outlet, reverse the plug. If it still does not fit,
contact a qualified electrician. Do not attempt
to defeat this safety feature.
5. CAUTION: To avoid fire or shock
hazard, plug the humidifier directly into a
120V AC electrical outlet. To avoid risk of
fire, shock or personal injury use an do not
extension cord or power strip.
6. The humidifier should always be
unplugged and emptied when not in
operation or while being cleaned. Shut
off and unplug humidifier before moving.
Do not move or tilt humidifier while it is
in operation. Plug and unplug unit with
dry hands. pull by cord.Never
7. Do not operate the humidifier without
water. Turn off and unplug unit when
tank is empty.
8. Humidifier requires regular cleaning. Refer
to and follow cleaning instructions.
9. Do not operate outdoors; this humidifier
is intended for indoor residential use only.
10. Do not cover or insert objects into any
openings on the unit.
11. Do not block intake or output vents.
12. Do not attempt to repair or adjust any
electrical or mechanical functions on
this humidifier. Doing so will void your
warranty.
13. Do not place in direct sunlight, high
temperature areas or near computers or
sensitive electronic equipment.
14. Do not touch the nebulizer while the unit is
plugged in, as burns could result.
15. Do not add any medications (e.g. liquid
inhalant, Vicks VapoSteam® or oils)
into Mist Outlet, Water Reservoir or
Water Tank.
SAVE THESE INSTRUCTIONS
4
SETTING UP YOUR HUMIDIFIER SETTING UP YOUR HUMIDIFIER (CONTINUED) (C
This humidifier uses a float system to regulate the water flow from the Tank to the Reservoir.
The Float Paddle must be properly installed for the unit to operate. If not properly installed,
water may not flow into the Reservoir or it may leak from the Base. The Float Paddle is
designed to be easy to install and remove.
CAUTION: Improper placement of the Float Paddle could result in leaking or water
not feeding to the Reservoir.
1. Remove Water Tank.
2. Line up Float Paddle with the float paddle shape on the bottom of the Reservoir.
3. Place Float Rod over both Brackets and press firmly until you hear it click into
both Brackets.
4. Pull gently up on the Float Rod to be sure it doesn’t pop out of the Brackets.
5. Replace Tank in Base.
If using the optional demineralization cartridge, see next section Installing
Demineralization Cartridge.
Float Paddle Installation – required for humidifier to operate
High mineral content in your water, also known as hard water, may cause a white mineral
residue to accumulate on surfaces in the room near the humidifier. This mineral residue is
commonly referred to as white dust. The higher the mineral content (hardness) of your water,
the greater the potential that an ultrasonic humidifier may produce white dust.
White dust is not a result of a defect or flaw in the humidifier. It is a result of the amount of
minerals suspended in the water you are using.
Hard Water and White Dust
Top Le Haut
Step 2
Step 5 Step 4
$
MAX
MAX
Step 3
Top Le Haut
“Click
$
MAX
MAX
Float
Rod
Float
Paddle
Brackets
Step 1


Product specificaties

Merk: Honeywell
Categorie: Luchtbevochtiger
Model: HUL570

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell HUL570 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Luchtbevochtiger Honeywell

Handleiding Luchtbevochtiger

Nieuwste handleidingen voor Luchtbevochtiger