INSTALLATION INSTRUCTIONS
69-1341EF-07
H8908A/B Humidistat;
H8908C/D Dehumidistat
APPLICATION
The H8908 family of low-voltage humidistats/
dehumidistats provide accurate control of whole house
humidifiers, dehumidifiers, and ventilators. They have a
snap-acting, dust-proof SPST switch and can be
mounted to a duct or wall.
Before Installing this Product...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a hazard-
ous condition.
2. Check the ratings given in the instructions and on
the product to make sure the product is suitable for
your application.
3. Installer must be a trained, experienced service
technician.
CAUTION
Personal Injury Hazard.
Power supply can cause electrical shock.
Disconnect power supply before beginning
installation.
NOTE: The H8908 electrical connections are not
shared with the thermostat.
Fig. 1. H8908A,D control.
Fig. 2. H8908B,C control.
M24726
Humidity Control
Régulateur d'humidité
-20 F
-10 F
0 F
+10 F
+20 F
Over 20 F
15%
20%
25%
30%
35%
40%
HUMIDIT Y
SETT ING
OUTDOOR
TEMPERATUR E
-30 C
-25 C
-20 C
-10 C
-5 C
Over 0 C
M13371
CASE REMOVAL
SLOT
HOLE FOR WIRING
THE DUCT MOUNTING
INSTALLATIONS
H8908A/B HUMIDISTAT; H8908C/D DEHUMIDISTAT
69-1341EF—07 2
DUCT INSTALLATION
1. Choose a location on the duct.
Fig. 3. Duct installation locations.
2. Apply sticker template to duct and drill holes for
mounting screws. Cut along the dotted line of the
template with metal shears or tin snips.
Fig. 4. Drill and cut holes in duct.
3. Run two-fan, low-voltage wire to the mounting loca-
tion on the duct. See Fig. 5.
IMPORTANT
Use rated 18-22 gauge wire. Leave approximately
6 in. of wire to properly connect the humidistat.
Fig. 5. Run wire to the mounting location.
REMOTE MOUNT
INSTALLATION
1. Choose a location in the living area.
NOTE: Select a location clear of drafts or excessive
humidity. Avoid mounting near doors or win-
dows, or in bathrooms or kitchens. See Fig. 6.
Fig. 6. Choose a location in the living area.
2. Cut 1 in. diameter wire hole in wall.
3. Run two-fan, low-voltage wire to the mounting loca-
tion in the living area.
IMPORTANT
Use rated 18-22 gauge wire. Leave approxi-
mately 6 in. of wire to properly connect the humi-
distat.
Fig. 7. Run wire to the mounting location.
ALTERNATE LOCATION
RETURN
AIR
RETURN
AIR
6 in. (152 mm)
MINIMUM 15 in. (381 mm)
MINIMUM
BEST
LOCATION
RETURN AIR DUCT
M13369
M24800
M24720
TWO-FAN 18-22 GAUGE WIRE
SUPPLY
RETURN
M24718
M24721
H8908A/B HUMIDISTAT; H8908C/D DEHUMIDISTAT
3 69-1341EF—07
4. Remove the base bracket from the humidistat. For
duct mount, slide the black gasket onto the base
bracket. See Fig. 8.
NOTE: Use gasket only when mounting the control to
ductwork. Leave off when mounting to a wall.
Fig. 8. Seal base bracket.
5. Secure the base bracket to the duct or remote loca-
tion. Secure to the duct with four 1-in. (25 mm)
screws (provided) or to the wall with two 1-in. (25
mm) screws (provided).
Fig. 9. Mount base bracket to duct or remote location.
M24733
M24722


Product specificaties

Merk: Honeywell
Categorie: Luchtbevochtiger
Model: H8908B

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell H8908B stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Luchtbevochtiger Honeywell

Handleiding Luchtbevochtiger

Nieuwste handleidingen voor Luchtbevochtiger