Honeywell Home Comfort+ HR30 Handleiding

Honeywell Heater Home Comfort+ HR30

Lees hieronder de 📖 handleiding in het Nederlandse voor Honeywell Home Comfort+ HR30 (12 pagina's) in de categorie Heater. Deze handleiding was nuttig voor 51 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
- 1 -
2. Brief description
With the electronic radiator controller you can set your
room temperature exactly to your requirements while
additionally saving energy.
iLowering the room temperature by 1 °C saves
approx. 6% energy!
User-friendly
• Large adjustable display with backlight.
• Convenient programming through removal of the
radiator controller from the valve.
Installation
• The radiator controller fits on the most common
radiator valves M30 x 1.5.
• After being mounted, the radiator controller operates
immediately with the factory setting.
Functions for increased comfort
• Individual heating program for each weekday.
• Up to 6 switching points per day and three different
temperatures.
• Operating modes Holiday, Party, Day off can easily be
activated.
• Parameters can be set individually, see Section 9.
Energy-saving functions
• With the window function an open window is
recognised and the radiator valve closed.
• In ECO mode the room temperature is decreased by
3 °C.
• Optimised heating or lowering of the room
temperature.
CAUTION
Danger of malfunctions!
fUse the radiator controller only in
accordance with these operating
instructions.
fDo not allow children to play with the
radiator controller.
3. Installation
Ready to operate in three steps:
• Inserting batteries
• Setting the language, time and date
• Mounting – FINISHED
1. Scope of delivery
The radiator controller packaging contains:
4
3
1
2
1 Radiator controller, without batteries
2 Valve baseplate M30 x 1.5
3 Display element
4 Bag with adapters (Danfoss RA, RAV, RAVL)
WARNING
Danger of suffocation!
fKeep packaging materials away from
children.
Electronic
Radiator controller
HR30
- 2 -
Inserting/changing batteries
The radiator controller is set for the following battery
type:
• 2 Alkaline mignon cells 1.5 V, type LR6, AA, AM3
You can alternatively use the following batteries/
accumulators:
• Lithium 1.5 V, type LR6, AA, AM3
• NiMH 1.5 V, type LR6, AA, AM3
iIf lithium or NiMH batteries are used, Parameter 14
has to be set correctly, see Section 9.
3.2.
1.
+
+
1. Move the front part slightly upwards and remove it
downwards.
The battery compartment is now accessible.
2. Insert the batteries.
Ensure that the polarity is correct.
3. Put the front part back on and push downward.
The software version number, then the language
deutsch (German) is displayed.
4. If applicable, use the adjustment dial to select a
different language.
5. Confirm the selected language with the button. OK
hour is displayed.
iThe language selection is only displayed during initial
commissioning. During future battery changes setting
of time and date is prompted directly.
iThe battery life of new mignon cells amounts to
approx. 2 years. The batteries need changing when
the symbol flashes. All the settings are retained
when the batteries are changed.
WARNING
Explosion hazard!
fNon-rechargeable batteries.
fNever short-circuit batteries or throw them
intore.
fDispose of used batteries ecologically.
Setting the time and date
1. When hour is displayed, use the adjustment dial to
set the current hour and confirm with . OK
minute is displayed.
2. Use the adjustment dial to set the current minute and
confirm with . OK
year is displayed.
3. Use the adjustment dial to set the current year and
confirm with . OK
month is displayed.
4. Use the adjustment dial to set the current month and
confirm with . OK
day is displayed.
5. Use the adjustment dial to set the current day and
confirm with OK .
The normal display with set temperature and selected
operating mode is displayed.
Mounting the radiator controller
The radiator controller can be mounted easily on all
common radiator valves with a connection M30 x 1.5
without causing dirt or water staining.
WARNING
Damage to the radiator controller due
to short-circuiting through humidity and
moisture!
fMount the radiator controller in dry, closed
rooms only.
fProtect the radiator controller against
humidity, moisture, dust, direct sunlight or
high heat irradiation.
Removing the old thermostat head
1.
2.
1. Turn the old thermostat head to the left until it stops
and loosen the mounting.
2. Remove the old thermostat head from the radiator
valve.
- 3 -
Selecting the adapter
The radiator controller fits on the most common radiator
valves M30 x 1.5. Adapters are required for some valve
types.
1. Check whether an adapter is required and, if
necessary, select the appropriate adapter.
Make Illustration Adapter
Valves M30 x
1.5 Honeywell-
Braukmann,
MNG, Heimeier,
Oventrop
Not
required
Danfoss RA Supplied
Danfoss RAV Supplied
Danfoss RAVL Supplied
2. Slide the adapter onto the radiator valve and turn it
until you feel it click into place.
3. If necessary, screw the adapter tight with a screw.
Mounting the valve baseplate
1a
1b
1. Separate the valve baseplate from the radiator
controller. To do so, slide the slide towards the .
3.
2.
2. Turn the adjustment dial of the valve baseplate anti-
clockwise until it stops.
3. Put the valve baseplate onto the radiator valve or the
adapter and tighten by hand (without tools!).
Mounting the radiator controller
1.3.
2.
1. Ensure that the slide at the radiator controller is in the
open position.
2. Push the radiator controller onto the valve baseplate
so that the geer teeth catch and are no longer visible.
3. Lock the radiator controller in the end position. To do
so, slide the slide towards the .
The radiator controller carries out a self test and after
1 minute displays cycl. Subsequently the radiator
controller changes to automatic mode.
iThe radiator controller only functions if it is
interlocked in the end position.
FINISHED! – Your radiator controller is now ready for
operation with the factory setting!
Securing controller and battery compartment
iThe radiator controller and battery compartment
can be secured against being removed or opened by
means of a screw. These screws are not included in
the packaging.
Countersunk screws
Torx/corss recess 2.2x8mm
Type: WIN1412-KC22X8-Z or
WIN1412-KB22X8-Z


Product specificaties

Merk: Honeywell
Categorie: Heater
Model: Home Comfort+ HR30

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell Home Comfort+ HR30 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Heater Honeywell

Handleiding Heater

Nieuwste handleidingen voor Heater