Honeywell DHM065R4000 Handleiding


Bekijk gratis de handleiding van Honeywell DHM065R4000 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 5 mensen en kreeg gemiddeld 4.5 sterren uit 6 reviews. Heb je een vraag over Honeywell DHM065R4000 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
DHM065R4000
®
Whole Home Dehumidifier
EN User Guide
Access User Manual
To access the full user manual scan the QR
Code or visit:
info.honeywellhome.com/dhmr4000-um
Using the On board Controller
control or an external control such as an IAQ thermostat or
dehumidistat control. If the dehumidifer is controlled by an
IAQ thermostat or dehumidistat control, follow the
instructions for that control.
1
History displays
l
The number of compressor starts
l
Compressor Runtime (Total hours of compressor
Runtime for Life of Product)
l
FW/HW/VR (Firmware, Hardware, Version)
l
Filter Life Months (how much time is left until
Filter replacement timer expires)
2
Settings
The settings in this menu should only be set by the
installing contractor.
3
Relative%
Displays the RH reading of the sensor. The sensor is
in dehumidifier, not the controller.
4
Status
l
Idle
l
Dehumidifying
l
Air Sampling (When using the onboard controller
the dehumidifier runs the internal fan 3 minutes
every 30 minutes to sample air from the space to
get a relative humidity reading.)
l
Defrosting
l
Compressor Protection. (A minimum of 3
minutes since last compressor start or stop.)
Setting for Relative Humidity
Hold Button
This is used by the installer for testing the dehu-
midifier and is not meant for use during normal
operation.
Up and Down Arrow Buttons
These buttons adjust the Relative Humidity setting
from Home Screen or adjust settings in the Setting
Menu
Alerts
When an alert is active, it will display an alert Icon.
See Alert section for accessing alerts.
Alarms (Image Below)
Alarms shut down the system and the message is
displayed as scrolling text in display.
Alerts
Alert CodePotential Cause
01-Coil freeze
Evaporator coil is frozen. This could be caused
by insufficient air flow or cold, dry air.
03-Low temp
mode
Inlet air temperature is less than 50 °F during
a call for dehumidification.
04-Inlet air temp
too low
Inlet air temperature is less than -20 °F.
05-Compressor
overheating
This could be caused by insufficient air flow
due to a clogged filter or duct obstruction,
high inlet air temperatures, or a combination
of the two.
06-Outlet air tem-
perature too high
This could be caused by insufficient air flow
due to a clogged filter or duct obstruction,
high inlet air temperatures, or a combination
of the two.
07-Ambient high
temperature
The measured internal air temperature is
greater than 110F while the unit is in an idle
state or after three minutes of air sampling.
14-Voltage out of
spec
Measured line voltage is outside the range of
102 VAC - 132 VAC.
25-Onboard con-
troller com-
munication error
The onboard controller lost communication
with the dehumidifier.
26-Ambient
sensor com-
munication fail-
ure
The ambient sensor in the onboard display
controller failed.
30-Air flow
blocked
This could be caused by insufficient air flow
due to a clogged filter or duct obstruction.
40-Water leak
The normally closed float switch has opened
and there is an open circuit between the two
FLOAT terminals or the water leak detection
rope has detected water.
51-Continuous
runtime
Compressor has been running continuously
for more than 25 hours.
70-Change filter
The selected filter change time period has
expired.
71-Frequent coil
freeze
ALERT 01 was generated more than eight
times in a 24-hour period.
72-Frequent air
blockage
ALERT 30 was generated more than three
times in a 24-hour period.
73-Frequent
water leakage
ALERT 40 was generated more than two times
in a 24-hour period.
74-Unit under-
sized
More than three ALERT 02 (Continuous run-
time) alerts have been generated in an 80-
hour time period. The dehumidifier has insuf-
ficient capacity for this installation.
Maintenance
If you have a service contract with the installing pro, they
may do the required maintenance as well as verifying
proper operation during the service visit.
If replacing the filter or cleaning the drain line yourself,
consult the online User Manual.
Specifications
Input ratings DHM065
Electrical input voltage: 120 VAC, 60 Hz nominal, 4.3A. Rated
@26.C / 60% RH Cpsr 24 LRA / 4.25 RLA Impeller rated 0.58
FLA
Energy Performance: 2.23 liters (4.71 pints) per kilowatt hour
(KWH)
Standards and approval body requirements:ETL Listed per UL
60335-1, 60335-2-40, CSA C22.2 No. 60335-1 and 60335-2-40
Product weight: 61lb
Product dimensions in inches and mm (not including feet and
collars): 21.625 (533) L x 12.75 (305) W x 12.78 (305) H
Media Filter: MERV 8, 12H x 12W x 1D
Drain connection: 3/4” threaded female NPT connection.
Duct connections: 8round inlet and outlet. ABS plastic, com-
patible for connection to rigid or flexible ducting with sheet metal
screws and/or tape.
Cabinet: 20 gauge galvanized steel powder-coat painted. Insu-
lation: R value 1
Compressor: Rotary-style, 6.3 KBTU
Refrigerant: R32 @ 12.3 oz. 450 PSIG, High Side / 240 PSIG, Low
Side
Operating Temp Range (outside cabinet):3F to 13F (1.C
to 54.4°C)
Operating Humidity Range: 0-95% RH Specifications Input
Dehumidification Temperature Limits: 50°F to 110°F (1C to
43.5°C) Inlet Air Temperature
Safety
To obtain detailed safety-related information, consult the
“Safety Instructions Guide”.
Customer Assistance
For assistance with this product, please visit:
customer.resideo.com
Or call Resideo Customer Care toll-free at 1-800-633-3991
5-Year Limited Warranty
This is a Trade Product:this warranty may be void if
it is not installed by a professional.
For warranty information go to:
resideo.info/US-Warranty-IAQ
To receive a printed version of the warranty, call
Resideo Customer Care toll-free at 1-800-633-3991
and a copy will be mailed free of charge.
33-00739EF-01
ResideoTechnologiesInc.
Scottsdale,AZ85254
1-800-633-3991
33-00739EF-01M.B.Rev08/25
©2025ResideoTechnologies,Inc.Allrightsreserved.TheHoneywellHome
trademarkisusedunderlicensefromHoneywellInternational,Inc.This
productmanufacturedbyResideoTechnologies,Inc.anditsaffiliates.

Beoordeel deze handleiding

4.5/5 (6 Beoordelingen)

Product specificaties

Merk: Honeywell
Categorie: Niet gecategoriseerd
Model: DHM065R4000

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell DHM065R4000 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden