Honeywell CT2400 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Honeywell CT2400 (14 pagina's) in de categorie Thermostaat. Deze handleiding was nuttig voor 58 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/14
PROGRAMMABLE
THERMOSTAT
BY HONEYWELL
PROGRAMMING AND INSTALLATION
INSTRUCTIONS
Weekday/Weekend (5-day/2-day)
Programmable Heat and/or Cool
Low Voltage (20 to 30 Vat)
Thermostat and Mounting Plate
Model CT2400
Limited One-Year Warranty
Honeywell warrants this prcduct, excluding battery, to be free from defects in the workmanship or materials, under normal use and sewice,
for a pericxl of one (1) year from the date of purchase by tha consumer. If, at any lime during the warranty period, the product is defective or
malfunctions, Honeywell shall repair or replace it (at Honeywel~s option) within a reasonable period of time.
[t
the product is defective,
(i)
retUrn
it,
with a bill of sale or,other dated prcof of purchase, to the retailer from which you purchased it, or
(ii) package it carefully, af0n9 wdh Proof of purchase (including date of purchaae) and a short description of the
ma ffuncf ion, and mail it, postage prepaid, to the following address
Honaywall Inc. in Canada: Honeywell Limited/Honeywell Limit6e
Return Goods Department Product Services ON 15-FFE
1050
13erkafdre
Lane 74o Ellesmere Road
Plymouth, MN 55441-4437 Scarborough, Ontario Ml P 2V9
This warranty does not cover removal or reinstallation coats. This warranty shall not apply if
It
is shown by Honeywell that the defect or
malfunction was caused by damage which occurred while the product was in the possession of a consumer.
Honeywell’s sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE
FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY
OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED
wARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILIV AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY
LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow Ilmitafions on how long an implied warranty lasts,
so the above limitation may not apply to you.
This warranty givas you specific legal rights, and You may have other
r!ghts
which vary from state to state.
If
you have any questions concerning this warranty, please write our Customer Assistance Center, Honeywell Inc.,
P.O.
Box 524, Minneapolis,
MN 55440-0524 or call 1-800-468-1502, Monday-Friday, 7:00 a.m. to 5:30 p.m., Central time. In Canada, write Retail Products ON1 5-02H,
Honeywell LimitecUHoneywell Limitee, 740 Ellesmere Road, Scarborough, Ontario Ml P 2V9.
35
TYPICAL ENERGY SAVINGS FOR REPRESENTATIVE CITIES IN THE U.S. AND CANADA
âť‘
SaviW
for
Gnc3-A.Oay
âť‘
SawrQSfciTv4c=3A-CUIy’
l&F
[5*C]
d—
l&F
[5-C]
decrease.
2
3
so%
~za%
H
fi
Q
“~~
m lwF
[50CI
dncrease+~F
[*C]
deciease
Thermostat patents pending.
grfes
WP+vxlmateiy
55
pemml
ol
these
savings.)
~z,,~h
Printed in U.S.A.
G.S.
7-93
@Honeywell
Inc.
1993
Welcome to the world of comfort and
energy savings with your new Honeywell
MagicStat@
programmable thermostat.
Your new thermostat will automatically
control the temperature in your home,
keeping you comfortable while saving energy
when programmed according to the instruc-
tions in this manual.
Direct any questions concerning the
application of this thermostat to Honeywell
Customer Assistance at 1-800-468-1502,
Monday-Friday
7:00
a.m.-53O p.m., Central
time.
@ RECYCLING THERMOSTAT
If this thermostat is replacing a thermostat
that contains mercury in a sealed tube (see
illustration below), do
not
place your old
thermostat in the trash. Contact your
Jocal
waste
management authority for instructions regarding
the recycling and proper disposal of your old
thermostat.
If you have questions, call Honeywell Inc.
at 1-800-468-1502.
Typical
location of a
MERCURY
SWITCH
mercury
switch in a
thermostat.
w
—.
o
0
M3701
Table Of Contents
STEP 1 Prepare For Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...2
STEP 2 Remove Old Thermostat
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
STEP 3 Install The Batteries
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
STEP 4 Program The Thermostat
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8
STEP 5 Adjust Fan Operation Switch, As Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
STEP 6 Adjust System On-Time, As Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
STEP 7 Mount Thermostat Mounting Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18
STEP 8 Wire Thermostat Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
..2O
STEP 9 Mount The Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...24
STEP 10 Check Thermostat Operation After Programming And installing . . . . . . . . . . . . . . . . . . . . . . ...25
STEP 11 Set The Fan And System Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...27
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...29
Limited One-Year Warranty
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
35
1
—
âť‘
Acquire tools and items below as needed. Also purchase two AA alkaline batteries; we
recommend Energizer batteries.
T
~
“(~,
CROSS-RECESSED
SCREWDRIVER iiAND OR POWER .
DRILL WITH 3/16 INCH
DRILL BIT, IF NEEDED, TO
DRILL HOLES IN WALL
~
~AsKING
TAPE
,F
WIRE CUTTEWSTRIPPER OR SHARP
KNIFE, IF NEEDED, TO STRIP WIRES NEEDED, TO
Ll&EL
WIRES
AS DISCONNECTED FROM
OLD THERMOSTAT
UIall
ulEa-’-U
LEVEL, IF NEEDED, TO LEVEL
THERMOSTAT FOR APPEARANCE
M378B
3
~
Prepare For Installation
âť‘
Check Table 1 to make sure this thermostat is compatible with your system. If it is not, return
to retailer. For more information, call Honeywell Customer Assistance, toll-free 1-800-468-1502.
TABLE 1 -COMPATIBILITY CHART.
System Type
Compatible With CT2400
Gas-Standin~ Pilot
Yes
Gas-Electro~c
Ignition
Gas-Fired Boilers
EA
A
Gas—Millivolt
Oil-Fired Boilers
Y:AA
OWired Furnace
Yes
Electric Furnace Yes
Electric Air Conditioning Yes
Baseboard Electric (120/240 Line Volt)
No
Heat
PumpdMultistage
Equipment
No
.,-.
--
——-.,
I-,-
. . .
..L
---- .fin/n”n
.._i.
-:.-..:.
lNoI
compaurm
WIIrI
arly
I
al~+u
VUIL
cxrum.
~Compatible
with 2-wire Honeywell zone valves. Isolating relay required
for3-wire
thermo-
stats for zone valves. Not compatible with 2-wire White-Rodgers no. 1361 valves.
~Compatible
with
hot
water baseboard systems. Will not work efficiently on steam or
gravity systems.
7
_
Remove Old Thermostat
[1 Test to make certain that your heating
and cooling systems are working properly. If
either does not work, contact your local
heating/air conditioning dealer. To avoid
compressor damage, do not operate the
cooling system when outdoor temperature is
below 50° F[10° C].
âť‘
TURN OFF POWER to system at the
furnace, or at the fuse/circuit breaker panel.
U
Carefully unpack your new thermostat and
mounting plate; save the package of screws,
instructions and receipt.
U Remove cover from old thermostat. If it
does not snap off
when pulled firmly from the
bottom, check for a screw used to lock on the
cover.
Replacing a Clock Thermostat that has C
or Cl Clock Terminals?
If you are replacing a Honeywell
Chronotherm@
Thermostat, you may find one
or two wires that go to the C or Cl clock
terminals on the Chronotherm Thermostat
wiring
wallplate.
Do not allow them to touch,
or you may damage your transformer.
Disconnect the wires and wrap them sepa-
rately, using electrical tape. Do not wrap them
together. Place the wires where they will not
interfere with the operation of the new
thermostat. Record the colors and terminal
designation labels of the remaining wires.
Six or more wires?
If there are six or more wires (excluding
clock wires attached to terminals), you
most likely have a variation of a heat pump
âť‘
Loosen screws holding thermostat to
subbase,
wallplate
or wall, and lift away.
U
Disconnect wires from old thermostat or
subbase. As you disconnect each wire, use
masking tape to label it with the old terminal
designation. If there are only two wires, they
do not need to be labeled. If there is an extra
wire that is not connected to your old thermo-
stat, you will
ako
not be connecting it to your
new thermostat. Keep the wires from falling
back into the wall by wrapping them around a
pencil as shown.
4
——.
.
—
or multistage system. The thermostat is
not
compatible with such systems so return
the product to the place of purchase. If you
would like information about which program-
mable thermostats will work with your system,
call Honeywell Customer Assistance at
1-800-468-1502.
Three thermostat wires?
If you have three wires for heating only and
can operate the fan using the fan ON switch,
this thermostat will work with your system.
However, some hot water (zoned) heating
systems have three thermostat wires. The
thermostat will not work without installing an
isolating relay on these systems. For details,
call Honeywell Customer Assistance at 1-800-
468-1502.
5


Product specificaties

Merk: Honeywell
Categorie: Thermostaat
Model: CT2400

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell CT2400 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermostaat Honeywell

Handleiding Thermostaat

Nieuwste handleidingen voor Thermostaat