Honeywell 6152 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Honeywell 6152 (4 pagina's) in de categorie Toegangscontrolesysteem. Deze handleiding was nuttig voor 44 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
ADEMCO 6152 / / 6152V 6152ZN Remote Keypad
User Guide
Addressable Fixed English & Voice Fixed English Keypads
= READY to Arm
= NOT READY to Arm
= System ARMED
= System NOT ARMED
Arming Keys
6152V: Message Indicators
6152-6152V-KEYPAD-LBLD-UG-07-19-13_1
= Recording Message
= No message
= Message Recorded
Programmable
Function Keys*
Sounder
6152V Microphone
See the keypad’s User Guide for details.
6152V Keys
*
The Function Keys can be be programmed
for special functions or panic alarm activations.
See the Function Keys section and check with
the system installer for more information.
Fixed Word Display
2-Digit Zone Identifier
The ‘21’ digits are used for specific
trouble indications. Refer to the
control panel instructions for details.
ALARM
FIRE
AWAY
BYPASS
STAY
CHECK
INSTANT CANCELED
NO NIGHT AC
NOT READY
CHIME BAT
TESTPHONE
6152V VOICE CONTROL KEYS
KEY FUNCTION DESCRIPTION
VOLUME ADJUST
Refer to the 6152V Keypad Voice
Features section for details using these
keys.
PLAY/STOP RECORD
VOICE KEY
FUNCTION/RECORD
SETTINGS KEY
The Settings key provides an easy method to test the keypad display.
To enter Display Test mode, press and hold the key for 2 seconds.
SINGLE BUTTON ARMING
If desired, the Arming Keys can be set for Single Button Arming by following
prompts to store a valid user code in the keypad. (See the system User Guide
for details on programming user codes.)
When Single Button Arming is disabled, a valid user code is required to arm the
system with the Arming keys
- 2 -
Enabling Single Button Arming
1. Press and hold down the and keys at the same time for 3
seconds. The screen displays the keypad’s address.
2. Press to move to the User Code entry screen (the screen flashes
“u4”, “- -” and “- -.”)
3. Enter a valid four digit user code between 0000 – 9999
and press to
save and exit.
Recommended: Set a dedicated user code for this feature.
The user code must be entered for each keypad in the system where Single
Button Arming is desired.
Disabling Single Button Arming
1. Press and hold down the and keys at the same time for 3
seconds. The screen displays the keypad’s address.
2. Press to move to the User Code entry screen (the screen flashes
“u4”, “- -” and “- -.”)
3. Enter and then press to exit.
FUNCTION KEYS
The Function keys may be programmed by the installer
for special functions or alarm activations. Key pairs
may also be programmed for alarm activations.
To activate the Function keys, press and hold the key
for at least 2 seconds; key pairs are activated
immediately.
Check with the system installer for more information.
COMMERCIAL STAY MODES
For commercial controls, if Stay Mode 2 is programmed, refer to the controls
manuals and the table below for Stay mode arming.
Commercial Systems Stay Modes
+ 1 = Stay Mode 1
+ 2 = Stay Mode 2
= Stay Mode 3 (both Stay 1 and Stay 2 modes)
Note: Not intended for use with the VISTA-128/250 Series.
6152V KEYPAD VOICE FEATURES
Message Center
The keypads feature a voice message center that lets you record and playback
one message.
The message can be up to 2.5-minutes long
The message remains in the keypad’s memory until a new message is
recorded.
The volume control of the message is adjustable.
A or and
B or and
C or and
D
- 3 -
To record a message: Press + + keys. The MESSAGE
ICON ( ) will light, indicating recording is in progress.
Note: A message cannot be recorded during the Exit Delay period.
To end recording: Press key, the keypad will ‘ding’ twice to indicate
recording is ended. The MESSAGE ICON will flash indicating a
message is waiting to be played.
To play a message: Press +
+
. The recorded message
plays and the MESSAGE ICON turns off. The recorded message will
remain in memory until a new message is recorded.
To adjust the volume:
Press
+ +
to adjust the volume
one level. Volume levels are Low, Off, On, High and Medium. With
each level adjustment, the keypad announces “CHECK” (at Low,
Medium and High volumes), “ON” or “OFF” to verify the current setting.
Note: Adjusting the message volume also adjusts status volume. The volume
cannot be adjusted while playing a message.
Voice Mode
When Voice mode is enabled, the keypad announces basic system arming status
upon arming or disarming (e.g., “Disarmed, Ready to Arm,” “Armed Away”).
To enable the Voice mode: Adjust the keypad volume to “On” or “Check” (at the
desired volume).
To disable the Voice mode: Adjust the keypad volume toOff.”
Voice Chime
Each keypad can be set to announce faulted (opened) entry/exit or perimeter
zones when the control panel’s Chime mode is on.
To enable the Voice Chime mode: Adjust the keypad volume to “On” or
“Check” (at the desired volume) and turn on the keypad Chime mode
(Code + ).
When enabled, Voice Chime provides a voice status annunciation,
chime and display when any entry/exit or perimeter zone is faulted.
When the Voice mode is disabled but Chime mode is enabled, the
sounder will still provide Chime annunciations when zones are faulted.
Voice Status
The keypad can be set to announce current system status and display any
system and/or zone faults (if they exist).
To enable Voice Status: make sure Voice Chime mode is on, then:
To Announce Status:
Press
+
+
key once.
The respective system status is announced (e.g., “Disarmed, Ready to
Arm” or “Disarmed, Not Ready to Arm”).
Note: Status cannot be announced during the Exit Delay period.


Product specificaties

Merk: Honeywell
Categorie: Toegangscontrolesysteem
Model: 6152
Soort bediening: Knoppen
Kleur van het product: Wit
Breedte: 176 mm
Diepte: 25.9 mm
Hoogte: 123.9 mm
Gebruikershandleiding: Ja
Connectiviteitstechnologie: Bedraad
Certificering: UL, ULC, CAN/ULC-S545, ANSI/SIA, CE
Smartphone ondersteuning op afstand: Nee
Gebruiksvriendelijk: Ja
Stroomverbruik: 70 mA
Maximum aantal deuren: 1 deur(en)
Gemakkelijk te installeren: Ja
Aantal bewegingssensoren: 0 stuk(s)
Stroom in standby: 40 mA
Alarm-bedieningspaneel: Ja
Aantal deur-/raamsensoren: 0 stuk(s)

Heb je hulp nodig?

Als je hulp nodig hebt met Honeywell 6152 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Toegangscontrolesysteem Honeywell

Handleiding Toegangscontrolesysteem

Nieuwste handleidingen voor Toegangscontrolesysteem