Hisense HPA27C Handleiding

Hisense Airco HPA27C

Lees hieronder de 📖 handleiding in het Nederlandse voor Hisense HPA27C (31 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 54 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/31
Thank you very much for purchasing this Air Conditioner. Please
read this use and installation instructions carefully before installing
and using this appliance and keep this manual for future reference.
Model:
+HPA27C
+HPA30C
+
Hisense (Guangdong) Air Conditioning Co., Ltd.
No.8 Hisense Road Advanced Manufacturing ,
Jiangsha Demonstration Park,Jiangmen City,
Guangdong Province,P.R.China
1
TABLE OF CONTENTS
INSTALLATION REQUIREMENTS ................................................14
Tools and Parts ...........................................................................
14
Location Requirements ...............................................................15
Electrical Requirements ..............................................................15
INSTALLATION INSTRUCTIONS ..................................................15
Unpack the Air Conditioner .........................................................15
Install Local Air Conditioner(on the window)..... ..............
.
.
..
.
..
.
..
.
..
.
.. .
.
.. ...
.
.
.
.
.
. .
.
. ..
.
.
16
LOCAL .........................................19
IDENTIFICATION OF PARTS............................................10
Using the Remote Control..........................................................
21
.
..
Starting Your Air Local ........................................Conditioner 20
Complete Installation ...................................................................
18
Draining the Air Conditioner( Heating models)....... ................... 26
AIR CONDITIONER USE .
AIR CONDITIONER S AFETY.........................................................
14
Normal Sounds ..........................................................................
25
Draining the Air Conditioner .......................................................
26
Cleaning the Air Filter .................................................................
26
Storing After Use ........................................................................
2
6
TROUBLESHOOTING..................................................................
27
LOCAL AIR CONDITIONER CARE...... ...................................
26
Cleaning the Outside ..................................................................
26
SAFETY INSTRUCTIONS
This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without
supervision.
Children should be supervised to ensure that they do not play with the appliance.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid a hazard.The appliance shall be installed
in accordance with national wiring regulations.The range of external static pressures is
-0.2Pa to 0.2Pa.Keep the unit m or more apart from combustible surfaces 5 .
Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
.....
..
SAFEGUARDING THE ENVIRONMENT
This appliance is made of recyclable or re-usable material. Scrapping must be carried out in compliance
with local waste disposal regulations. Before scrapping it, make sure to cut off the mains cord so that the
appliance cannot be re-used.
For more detailed information on handling and recycling this product, contact your local authorities
who deal with the separate coll ection of rubbish or the shop where you bought the appliance.
SCRAP PING OF APPLIA NCE
This appliance is marked according to the European Directive 2012/19/EU, Waste Electrical and
Electronic Equipment (WEEE).
This marking indicates that this product should not be
disposed with other household wastes throughout
the EU. To prevent pos sible harm to the environment
or human health from uncontrolled waste disposal,
recycle it responsibly to promote the sustainable
reuse of material r esources. To return your used device,
please use the return and collection systems or contact
the retailer where the product was purchased.
They can take this product for environmental safe recy cling.
............................................2
SAFETY PRECAUTIONS.....
Safety precautions
Precautions for using R290 refrigerant
2
However, pay attention to the following points:
The basic installation work procedures are the same as the conventional refrigerant (R22 or R410A).
CAUTION
1. Transport of equipment containing flammable refrigerants
Compliance with the transport regulations
2. Marking of equipment using signs
Compliance with local regulations
3. Disposal of equipment using flammable refrigerants
Compliance with national regulations
4. Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer's
instructions.
5. Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical
damage to the equipment inside the package will not cause a leak of the
refrigerant charge.
The maximum number of pieces of equipment permitted to be stored together
will be determined by local regulations.
6. Information on servicing
6-1 Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety
checks are necessary to ensure that the risk of ignition is minimised. For repair
to the refrigerating system, the following precautions shall be complied with
prior to conducting work on the system.
6-2 Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the
risk of flammable gas or vapour being present while the work is being
performed.
6-3 General work area
All maintenance staff and others working in the local area shall be instructed
on the nature of work being carried out. Work in confined spaces shall be
avoided.
The area around the workspace shall be sectioned off. Ensure that the
conditions within the area have been made safe by control of flammable
material.
6-4 Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and
during work, to ensure the technician is aware of potentially flammable
atmospheres.
Ensure that the leak detection equipment being used is suitable for use with
flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically
safe.


Product specificaties

Merk: Hisense
Categorie: Airco
Model: HPA27C

Heb je hulp nodig?

Als je hulp nodig hebt met Hisense HPA27C stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Hisense

Handleiding Airco

Nieuwste handleidingen voor Airco