Bekijk gratis de handleiding van Hikvision DS-KIS102-P (2 pagina’s), behorend tot de categorie Intercomsysteem. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.7 sterren uit 9 reviews. Heb je een vraag over Hikvision DS-KIS102-P of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
DS-KIS102-P/Surface
1
2- WireVideo Intercom Kit
3
2
1
3
2
1
Wiring Diagram 1
Bit 1: outdoor unit address set, “ ” means outdoor unit 1 and
“ ” means outdoor unit 2.
Bit 2: Main cards set, “ ” means normal mode and “ ”
This 2-wire video intercom kit supports maximum system capacity of 2 outdoor units, 3 indoor units and 1 surveillance camera.
It has rich features including intercom, monitoring, unlocking, mute, alarm and so on.
ON
2
1
ON
2
1
ON
2
1
ON
2
1
O
Tampering switch
Outdoor unit
Indoor unit installaon
1. Fix the bracket on the wall with screws. (1.4-1.6m high from the ground )
2. Connect the wires according to the wiring diagram.
3. Hang on the bracket.
4. Connect to power supply.
Outdoor unit installation
Name Plate
Rain shade
Camera
CALL button
Speaker
Microphone
Indoor unit
Installation Instruction
1. Fasten the rain shade on the wall with screws. (1.4-1.6m high from the ground)
2. Connect the wires according to the wiring diagram.
3. Fix into the rain shade and fasten the bottom with screws.
Microphone
Monitor
Lock 1
Lock 2
Talk
MenuButton
Down
Up
Card Reader
Photocell
Analog Camera
(Extension)
External
power supply
DC12V 400mA
Electric Lock
Lock1
Snapshot
Exit button
for Lock 2
NOTE: When setting bit 2 to Add Main Cards mode, error
may happen when calling and answering the call.
123456
3
2
1
1234
ON
2
1
O
AC100-240V
50/60Hz
DC 15V
123
VDD
GND
VIDEO
123132
Door
Sensor 1
Door
Sensor 2
Indoor unit
Outdoor unit
DIP switch
Non Polarity
Lock2 (dry contact)
Electric
Lock
Normally open
Power supply
for unlocking
Magnetic
lock
Power supply
for unlocking
Normally closed
30V/2A
Exit button
for Lock 1
DIP Switch on the outdoor unit
Bit 1: Main/Sub unit set, slide to ON
position to set it as a main unit.
Bit 2: Turn on/off the coin battery.
NO
NO
1
2
12
NOTE:
For the bit 2, slide to ON position before use.
Otherwise, system will not save the date and
time setting during a power outage. Factory
default set is OFF.
ON
12
3
2
1
3
2
1
Lock2 (dry contact)
Electric
Lock
Normally open
Power supply
for unlocking
Magnetic
lock
Power supply
for unlocking
Normally closed
30V/2A
indoor subunit 2#
NOTICES
Turn off the power before wiring.
Aer installaon, if the product doesn't work, check if wires are
connected properly and securely.
Use a slightly damp so cloth to clean the camera or screen.
The outdoor unit must not be directly exposed to sunlight.
If it is unable to unlock, check if wires are connected properly and
securely. Also, make sure the voltage for unlocking is sufficient.
The image quality may be interfered by strong electromagnec
signals, therefore, when using the product, avoid the
electromagnec sources such as motor and transformer and make
sure the circumstance is barrier-free and no interference.
Connecon with 2-Core Cable
123132
Door
Sensor 1
Door
Sensor 2
123456
3
2
1
ON
2
1
A
AC100-240V
50/60Hz
123456
1234
AC100-240V
50/60Hz
3
2
1
ON
2
1
ON
2
1
ON
2
1
DC 15V
DC 15V
B
C
C
1234
123
123
VDD
GND
VIDEO
DIP switch
Lock1
DC 12V ≤400mA
Electric Lock
Lock1
123132
Door
Sensor 1
Door
Sensor 2
Analog Camera
(Extension)
External
power supply
main unit
Outdoor unit1
Outdoor unit2
indoor subunit 1#
123456
1234
AC100-240V
50/60Hz
DC 15V
3
2
1
3
2
1
Lock2 (dry contact)
Electric
Lock
Normally open
Power supply
for unlocking
Magnetic
lock
Power supply
for unlocking
Normally closed
30V/2A
A
Press down on the buon, and insert
the wire in the corresponding hole.
Release the buon to clamp the wire
in place. Gently pull the wire
to see if they are clamped ghtly.
3
2
1 8
7
6
5
4
DC 12V ≤400mA
Electric Lock
NOTE: To make system work, the outdoor unit must be
connected to the main indoor unit.
ON
12
ON
12
ON
12
ON
12
ON
12
Exit button
for Lock 2
Exit button
for Lock 1
Bit 1: Main/Sub unit set, slide to
ON position to set it as a main unit.
Bit 2: Turn on/off the coin battery.
NO
NO
1
2
12
Exit button
for Lock 2
Exit button
for Lock 1
. Cable between the outdoor unit and indoor unit:
- 0~15m: RVV2 × 0.5mm²
- 30~50m: RVV2 ×0.75mm²
- 50~100m: RVV2 × 1.0mm² (ONLY suitable for Wiring Diagram 1)
. Cable between indoor units:
- 0~20m: RVV2 × 0.5mm²
- 20~30m: RVV2 × 0.75mm²
. Cable for locks:
- 0~10m: RVV2 × 1.0mm²
Connection with Twisted 2-Core Cable
. Cable between the outdoor unit and indoor unit:
- 0~30m: RVV2 × 0.5mm²
- 30~70m: RVV2 ×0.75mm²
- 70~100m: RVV2 × 1.0mm²
. Cable between indoor units:
- 0~30m: RVV2 × 0.5mm²
- 30~40m: RVV2 × 0.75mm²
. Cable for locks:
0~10m: RVV2 × 1.0mm²
NOTE: The cable with pure copper conductor must be
used. Alloy or other materials will affect the usage.
B
A
B
C
A
B
C
1
2
3
2
3
4
Wiring Diagram 2
4
OVERVIEW

Beoordeel deze handleiding

4.7/5 (9 Beoordelingen)

Product specificaties

Merk: Hikvision
Categorie: Intercomsysteem
Model: DS-KIS102-P

Heb je hulp nodig?

Als je hulp nodig hebt met Hikvision DS-KIS102-P stel dan hieronder een vraag en andere gebruikers zullen je antwoorden