Bekijk gratis de handleiding van Hikvision DS-K3B530X-M (151 pagina’s), behorend tot de categorie Toegangscontrolesysteem. Deze gids werd als nuttig beoordeeld door 24 mensen en kreeg gemiddeld 4.9 sterren uit 4 reviews. Heb je een vraag over Hikvision DS-K3B530X-M of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/151
DS-K3B530X Series
Swing Barrier
Quick Start Guide
UD30988B-A
©2023 HangzhouHikvisionDigital Technology Co., Ltd.Allrights reserved.
About this Manual
The Manual includes instructions for using andmanaging theProduct. Pictures, charts,
images and allotherinformation hereinafter are for description and explanation only.
The information contained in the Manualissubject to change, without notice, dueto
firmware updatesor other reasons. Please findthe latest versionof this Manual atthe
Hikvisionwebsite (https://www.hikvision.com/).
Please use this Manual with the guidance andassistance of professionalstrainedin
supporting the Product.
Trademarks
andotherHikvision’s trademarksandlogosare the propertiesofHikvision in
various jurisdictions.
Other trademarksandlogosmentioned are the properties of their respective owners.
Disclaimer
TO THE MAXIMUMEXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE
PRODUCT DESCRIBED,WITHITSHARDWARE,SOFTWAREANDFIRMWARE, AREPROVIDED
ASISANDWITHALLFAULTSAND ERRORS”. HIKVISIONMAKESNOWARRANTIES,
EXPRESS OR IMPLIED,INCLUDING WITHOUT LIMITATION,MERCHANTABILITY,
SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE.THEUSE OF THE
PRODUCT BYYOUISAT YOUR OWN RISK. IN NO EVENT WILLHIKVISION BE LIABLE TO YOU
FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING,
AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION,
OR LOSSOFDATA,CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION,WHETHER
BASEDONBREACH OF CONTRACT, TORT(INCLUDING NEGLIGENCE), PRODUCT LIABILITY,
OROTHERWISE,INCONNECTIONWITHTHEUSEOFTHEPRODUCT, EVENIFHIKVISION
HAS BEENADVISED OF THEPOSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGETHATTHE NATURE OF THE INTERNET PROVIDESFOR INHERENT
SECURITYRISKS, AND HIKVISIONSHALL NOT TAKE ANYRESPONSIBILITIES FOR ABNORMAL
OPERATION,PRIVACY LEAKAGEOROTHER DAMAGES RESULTING FROMCYBER-ATTACK,
HACKER ATTACK, VIRUS INFECTION,OROTHER INTERNET SECURITY RISKS;HOWEVER,
HIKVISIONWILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREETO USE THIS PRODUCTINCOMPLIANCE WITH ALL APPLICABLE LAWS,AND
YOUARE SOLELY RESPONSIBLE FOR ENSURINGTHAT YOUR USECONFORMSTOTHE
APPLICABLELAW. ESPECIALLY, YOUARERESPONSIBLE,FORUSING THISPRODUCTINA
MANNER THAT DOES NOT INFRINGEONTHE RIGHTS OF THIRD PARTIES, INCLUDING
WITHOUTLIMITATION, RIGHTSOFPUBLICITY, INTELLECTUALPROPERTYRIGHTS,ORDATA
PROTECTIONAND OTHER PRIVACY RIGHTS. YOU SHALL NOTUSE THISPRODUCT FOR ANY
PROHIBITED END-USES,INCLUDING THE DEVELOPMENTORPRODUCTION OFWEAPONS
OFMASSDESTRUCTION,THEDEVELOPMENTOR PRODUCTIONOFCHEMICAL OR
BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TOANY NUCLEAR
EXPLOSIVE OR UNSAFENUCLEAR FUEL-CYCLE,ORINSUPPORT OF HUMAN RIGHTS
ABUSES.
INTHE EVENT OF ANY CONFLICTSBETWEEN THIS MANUAL AND THEAPPLICABLE LAW,
THE LATTER PREVAILS.
Data Protection
Duringtheuse ofdevice,personaldatawillbecollected,storedandprocessed.To
protectdata,the development ofHikvisiondevicesincorporates privacy by design
principles.For example, for devicewith facialrecognition features, biometrics datais
storedinyourdevicewithencryptionmethod;for fingerprintdevice,onlyfingerprint
template willbesaved, whichisimpossible toreconstruct a fingerprint image.
As datacontroller,you areadvised tocollect,store, process and transfer data in
accordance with the applicable data protection lawsandregulations, including without
limitation,conducting security controlstosafeguardpersonaldata,suchas,
implementingreasonable administrativeandphysicalsecuritycontrols,conductperiodic
reviewsand assessments of the effectiveness of yoursecuritycontrols.
1System Wiring2Installation
3Wiring
1.Drawa centralline onthe installation
surface of the leftorrightpedestal.
2. Drawother parallel lines for installing
the other pedestals.
Thedistance betweenthe nearest
two linesis L + 272mm. L representsthe
lane width.
3.Slot onthe installationsurface and dig
installation holesaccording to the hole
position. Put 4 expansion
bolts ofM12*120foreach pedestal.
4.Bury cables. Each lane buries 1 high
voltage cableand1lowvoltagecable.For
details, see the system wiring diagram.
Highvoltage:AC power input
Low voltage: interconnecting cable
(communication cableand 24V powercable)
andnetworkcommunication cable.
Thesupplied interconnectingpower cable
lengthis 5 mand communication cablelength
is3 m.
The suggested innerdiameter ofthe low
voltageconduitis larger than30 mm.
If you wantto buryboth ofthe ACpower cord
andthe lowvoltagecable, thetwo cables
should bein separated conduitstoavoid
interference.
Ifmoreperipherals arerequiredtoconnect,
youshould increase theconduit diameteror
buryanother conduitfortheexternalcables.
TheexternalAC powercordshould be
double-insulated.
Thenetworkcable mustbe CAT5e orthe
network cablehasbetter performance.
Steps:
1 1
1
13
3
4
4
2 2
2
2
Steps:
1.Prepareinstallationtools, checkthecomponents,and cleanthe installation base.
2.Remove4 screws ofeach pedestal whichfixthe 2side panels.
3.Removethe sidepanels andplace thepedestals tothe corresponded positions
according tothe entrance andexitmarks onthepedestals.
4.Secureeachpedestalwith 4nuts andfixthe sidepanels toits originalposition
with screws.
Make sure the deviceis installed onflatsurface.
Makesure thedevice ispowered off during installation and otheroperations.
The installationtoolsare putinside the package of thepedestal.
Ifthe installation areaisclosetothe wall,make
surethedistance betweenthepedestaland the
wallshouldbemorethan 20mm (60mm if
withfacerecognition terminals),oryoumight
cause damage tothe deviceor cannotopen the
pedestal's toppanel.
Dimension
Tamper
Interface
Main Lane Control Board
Indicator Board
Interface 1 (For
Authentication
Indicator Board)
Reserved
Fan
Communication
Interface
(For Main Extended
Interface Board, IR
Adapter Board, and
Lane Status
Indicator Board)
Encoder Interface
Power Supply
for Motor
Supercapacitor
Brake InterfaceBrake Interface
Reserved Reserved
Interconnecting
Interface
(For Sub Lane
Control Board)
Reserved
Access Control
Board Interface
Fire Input
Exit Button
12VDC Output
24VDC Input
Reserved
Indicator Board
Interface 1 (For
Authentication
Indicator Board)
Tamper
Interface
Fan
Communication
Interface
ForSub Extended
Interface Board,IR
Adapter Board, and
Lane Status Indicator
Board
Encoder Interface
Power Supplyfor
Motor
Supercapacitor
Reserved
12VDC Output
(Reserved)
BUS Interface
(ForSub Optional
Board )
Exit Button
24VDC Input
Interconnecting
Interface
(ForMain Lane
Control Board)
Sub LaneControl Board
Access Control Board (Optional)
Reserved
Loudspeaker
Interface
Reserved
Reserved
Network
Interface
SOCSerial Port
Wi-Fi Interface
MCU Serial PortUSB
Interface
DIP Switch
Main Lane
Control Board
Interface
Extended
Interface 12 VDCOutput
RS-485 Interface
(Entrance)
24 VDC Input
Reset Button
SOCand MCUserial portare for debuggingand
maintenance useonly.
Holdthe reset buttonfor5 s,the devicewill
beepfor3sandstartrestoringto factory
settings.
The DIPswitch isfor studymode settings and
keyfobpairing. Referto theuser manualfor
details.
RS-485Acorresponds to port 5on web andis
for QRcode scannerconnectionatentranceby
default;RS-485Ccorrespondstoport7 onweb
and isforcard reader connectionat entrance by
default.
Entrance
Main andSub Lane
Control Board
MainLane ControlBoard
SubLane ControlBoard
Authentication
Indicator Board
Authentication
Indicator BoardAuthentication
Indicator Board
Power Supply
Power Supply
Access Control Board
(Optional)
Access Control Board
(Optional)
Main Switch
Main Switch
Main Extended
Interface Board
Main Extended
Interface Board
SubExtended InterfaceBoard
Sub Extended
Interface Board
Card Reader Board
(Optional)
QRCode Scanner
(Optional)
NFC Board
NFC Board
Scan theQR code toview the videoguide.
CableHole:181 × 90
L
L+ 142
1349
466 181
90
60
130
L+ 272
L+ 402
Sub Lane Control Board
Sub Extended
Interface Board
Sub Lane IR
Adapter Board
Lane Status
Indicator Board
Lane Status
Indicator Board
Lane Status
Indicator Board
Lane Status
Indicator Board
Lane Status
Indicator Board
Lane Status
Indicator Board
NFC BoardNFC Board
Main SwitchMain Switch
Authentication
Indicator Board
Authentication Indicator BoardAuthentication Indicator Board
Sub Extended
Interface Board
Main Lane Control Board
Sub Lane Control Board
Main Lane Control
Board
AccessControl BoardAccessControl Board
Main Extended
Interface Board
Sub Lane IR
Adapter Board
Main Extended Interface Board
Unit: mm
Low VoltageLow Voltage
High Voltage
Entrance
Fix each pedestal with
4expansion boltsof
M12*120
60 mm
20 mm
Scanthe QRcodeto viewtheusermanual.
Keepglass barriersclean, dry and unblocked, inorder not to affect the IR detectors.
The diagram isfor reference.Dimensions maydiffer in models.
Unit: mm
Sub Lane IR
Adapter Board
Sub Lane IR AdapterBoard
1396
1000
1500
201.6
700
900650
50
130
142.5
842.5
2225.4
272.2 201.6

Beoordeel deze handleiding

4.9/5 (4 Beoordelingen)

Product specificaties

Merk: Hikvision
Categorie: Toegangscontrolesysteem
Model: DS-K3B530X-M

Heb je hulp nodig?

Als je hulp nodig hebt met Hikvision DS-K3B530X-M stel dan hieronder een vraag en andere gebruikers zullen je antwoorden