02/19 Model HCR8.50 Page 1 of 8
1455 Kleppe Lane (775) 359-4712 Sparks, NV 89431-6467 Fax (775) 359-7424
E-mail: [email protected] website: www.hawsco.com
No. 0110000525 (3)
NOTICE: This water chiller must be connected to the water supply using a dielectric coupling.
IMPORTANT! INSTALLER PLEASE NOTE
The grounding of electrical equipment such as telephone, computers, etc., to water lines is a
common procedure. This grounding may be in the building, or may occur away from the
building. This grounding can cause electrical feedback into a water chiller, creating an
electrolysis which causes a metallic taste or an increase in the metal content of the water.
This condition is avoidable by using the proper materials indicated under Installation Section.
SAFETY PRECAUTIONS
A. Water supply line pressure must be maintained between 20 psi and 105 psi. Bi-level water
fountain units require a minimum of 40 psi.
B. Do not allow water to come into contact with live electrical wires because short-circuiting and
shocks can occur.
C. WARNING: Beware of rotating fans when covers are removed.
D. Care should be taken not to puncture refrigeration system lines. Some lines contain gas
under high pressure.
E. Install chiller to conform to all applicable codes, including the National Electrical Code.
Model HCR8.50
Water Chiller
INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
Haws electric water chillers are not designed or recommended for outdoor or corrosive
environments such as enclosed chlorinated pool areas.
Consideration must be made at the time of installation to adhere to state and/or local codes and
environmental/atmospheric conditions such as, but not limited to, dust, corrosion, freezing etc.
These conditions will void the warranty.
CAUTION! Prior to making any electrical
connections, verify with a voltmeter that power
from the service panel is off.
A ground-fault circuit breaker shall be installed
in the branch circuit supplying fountain
equipment. Reference NEC 422.52.
HCR8.50 is a 220-240VAC, 50 Hz remote chiller which provides up to 6.7 gallons (25 liters) per
hour of cold water when tested to ASHRAE 18. This chiller can provide chilled water to a wide
variety of water fountains. It can be concealed under a counter, between or within walls (check
local codes) or high on a wall or column. It is ideally suited for factories, cafeterias,
restaurants, schools and offices. Installation is intended to be performed by qualified persons
such as certified electricians and plumbers.
Installation, maintenance or cleaning shall not be performed by children.
Product specificaties
| Merk: | Haws |
| Categorie: | Niet gecategoriseerd |
| Model: | HCR8.50 |
Heb je hulp nodig?
Als je hulp nodig hebt met Haws HCR8.50 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Haws
16 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
3 April 2026
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
16 September 2026
16 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026
15 September 2026