Haws 8111FP Handleiding


Bekijk gratis de handleiding van Haws 8111FP (1 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 8 mensen en kreeg gemiddeld 4.6 sterren uit 4.5 reviews. Heb je een vraag over Haws 8111FP of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/1
1676mm
FLOOR LINE
2083mm TO 2438mm
82" TO 96"
5/8" 16mm
SHOWER SUPPORT
WALL BY OTHERS
GUIDE SLEEVE THROUGH
VALVE STEM
66" MAX
FACE
DRAIN
WALL
1" IPS (FEMALE)
SUPPLY
SLOPE PIPE DOWNWARD
1" IPS (FEMALE)
AREA
HEATED
FOR DRAINAGE
381mm
15" MAX WALL
THICKNESS
144mm
5-11/16"
3 3/4"
16 1/16"
23-15/16" MIN
608mm
4
4
(FEMALE)
NOTES:
1. DIMENSIONS MAY VARY BY ± 1/2 INCH [13mm].
2. TO COMPLY WITH ANSI Z358.1-2009 FOR EMERGENCY SHOWER EQUIPMENT:
- UNIT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND ACCEPTABLE PLUMBING PRACTICES.
- SHOWER SHALL BE POSITIONED SO THAT SHOWER HEAD IS NOT LESS THAN 208.3 CM (82 IN.) NOR MORE THAN 243.8 CM (96 IN.)
FROM SURFACE ON WHICH USER STANDS.
- SHOWER SPRAY PATTERN SHALL HAVE A MINIMUM DIAMETER OF 50.8 CM (20 IN.) AT 152.4 CM (60 IN.) ABOVE SURFACE ON WHICH
USER STANDS, AND CENTER OF SPRAY PATTERN SHALL BE LOCATED AT LEAST 40.6 CM (16 IN.) FROM ANY OBSTRUCTION.
3 FOLLOWING THESE DIMENSIONS WILL AUTOMATICALLY PROVIDE ADHERENCE TO ANSI REQUIREMENTS STATED ABOVE.
4 1" IPS GALVANIZED PIPE NOT SUPPLIED.
5 DO NOT USE REGULAR PIPE SEALANT. IF NECESSARY USE DOW CORNING 832 SEALANT PLACING 5 SMALL
BEADS ON THE MALE THREADS, JUST ABOVE THE FIRST THREAD.
5
5
APPROVED:
DRAWN:
PART NUMBER
DRAWING NO.
SCALE:
SHEET OF
REV
DRAWING TYPE: SIZE: A
BY:ECN NO.
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
Haws Corporation - All Rights Reserved.
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
C
R
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: HAWS@HAWSCO.COM
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WI THOUT NOTICE.
TRF
05/23/91
09438A00
13
0002080111.D
WALL MOUNTED FREEZE RESISTANT
8111FP DRENCH SHOWER
8:1
1 1
FV
10/21/14
FV
INSTALLATION
4921
2014


Product specificaties

Merk: Haws
Categorie: Niet gecategoriseerd
Model: 8111FP

Heb je hulp nodig?

Als je hulp nodig hebt met Haws 8111FP stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Haws

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd