Haier AS71FEBHRA Handleiding

Haier Airco AS71FEBHRA

Lees hieronder de đź“– handleiding in het Nederlandse voor Haier AS71FEBHRA (13 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 132 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/13
Please read this o
â—Ź
peration manual before using the air conditioner.
Keep this operation manual for future reference.
SPLIT TYPE ROOM AIR CONDITION
OPERATION MANUAL
ER
AS18FEBHRA
AS09FBBHRA AS12FBBHRA
AS24FEBHRA
AS26FBBHRA
AS71FEBHRA
AS53FEBHRA
AS35FBBHRA
0010599996
AS28FFAHRA AS82FFAHRA
Parts and Functions
Indoor Unit
Outdoor Unit
â—Ź
Remote controller
Outer side of the controller
OUTLET CONNECTING PIPING
AND ELECTRICA
â—Ź
L WIRING
INLET DRAIN HOSE
â—Ź
4
Actual inlet grille may vary from the one shown in the
manual according to the product purchased
1. ECO SENSOR button
2. DRY button
3. COOL button
Used to set COOL operation.
4.
5.
n. o6 itcnufhcaefoyalpsiD
status
7. Operation mode display
8. TEMP display
9. FAN SPEED display
10. SWING display
Swing up/down display
swing left/right display
12. FAN button
13. QUIET button
14. HEAT button
15. SELF CLEAN button
Used to set DRY operation.
11. TIMER ON display
TIMER OFF display
CLOCK display
1
4
5
6
7
8
9
10
11
13
14
15
12
TEMP button
used to change setting
temperature
ON / OFF button
Display board
2
1
3
WIFI display
Ambient temp.display
When receiving the remote
control signal, display the set
temperature.
1
Inlet
Air Purifying Filter
(inside)
ON/OFF
Button
Inlet grille
(adjust left and
ow)
Vertical blade
right air fl Horizontal flap
(adjust up and down air flow
Don't adjust it manually)
Outlet
Display board
(inside)
NOTE:
a. Humidity display is unavailable on some models
b. If the model you buy has a WIFI function, press the“ON/OFF”
button for 5s to emit the WIFI binding signal. Once in the
binding mode, the APP will show how to bind.
Operation mode indicator
TIMER
3
2
ECO SENSO R
4
Signal receiver hole 2
3
4
SELF
CLEAN
Operation
Clock set
Note:
â—Ź
Note:
The distance between the signal transmission head and
the receiver hole should be within 7m without any obstacle
change-over wireless telephone is installed in the type
in receiving the signals, so the distance to the indoor unit
should be shorter.
Full display or unclear display during operation indicates the
batteries have been used up. Please change batteries.
â—Ź
If the remote controller can’t run normally during operation,
please remove the batteries and reload several minutes later
Hint:
â—Ź
Remove the batteries in case unit won’t be in usage for
a long period.
20. 10 ÂşC button
special heating set
function: 10 degree
heating maintaining
(valuable for RS)
18. buttonTIMER
23. SWING up/down button
24. SWING left/right button
19. buttonCLOCK
26. HEALTH AIRFLOW button
21. HEALTH button
28. CODE button
A-B yard
29. APPLY button
30. TURBO button
25. SLEEP button
19
20
21
22
23 24
25
26
27
28
29
30
18
22. SMART button
Used to set SMART
operation. (This function
is unavailable on some
models.)
27. LIGHT button
Control the lightening and
extinguishing of the indoor
LED display board.
Press CLOCK button,
Press “ ” or “ ” to set
correct time.
Each press will increase or
decrease 1min. If the button is
kept pressed, time will change
quickly.
press APPLY,
starts working.
1
2
3
2
Press “HEALTH”+“HEALTH AIRFLOW” simultaneously can
set and cancel the “LOCK” function ( ).
TURBO
TURBO
Haier Peaksmart enabled air-conditioners have a Demand
Response Mode display on the indoor unit.
The display could be labelled d1, d2, d3 (wording may
differ model to model).
odottahWnoitpircseDyalpsiDedoM
D
â—Ź
RM3 d3
Your air-conditioner will continue
to cool or heat during the peak
demand event. The energy
consumed by your air-conditioner
is capped to 75%.
No action is required.
DRM2 d2
Your air-conditioner will continue
to cool or heat during the peak
demand event. The energy
consumed by your air-conditioner
is capped to 50%.
No action is required.
DRM1 d1
Your air-conditioner is still turned
on and the fan will continue to
operate. Your compressor is
turned off and cool/hot air will no
longer be generated
DRM1 mode is only activated during
emergency demand management
situations. This mode will automatically reset
the device within 2 hours .If your air-con is in
this mode for longer than 2 hours please
contact Energex on 13 12 53.
(This function is unavailable on some models.)
These modes are described in more detail below:
Dred operation
TIMER
TIMER
If your Air Conditioner (AC) has a Connected Appliance Information
label located under the front cover as shown below, your AC is
WiFi Connect Enabled. A WiFi communication card is built into the
product allowing it to communicate with your smart phone for remote
monitoring, control and notifications.
Please visit www.haier.com.au/smart to learn more about connected
appliance features, and to learn what connected appliance apps will
work with your smart phone.
WiFi Setup


Product specificaties

Merk: Haier
Categorie: Airco
Model: AS71FEBHRA

Heb je hulp nodig?

Als je hulp nodig hebt met Haier AS71FEBHRA stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Haier

Handleiding Airco

Nieuwste handleidingen voor Airco