Universal switch insert 1gang/ Universal switch insert 2gang
Page 1/6
6W-5833D 08-2013
Universal switch insert 1gang/
Universal switch insert 2gang
Order no.: 8512 11 0x, 8512 22 0x
Operating instructions
1. Safety instructions
Electrical equipment may only be installed and assembled by a qualiîš¿ed electrician in
accordance with the relevant installation standards, guidelines, regulations, directives,
safety and accident prevention regulations of the country.
Failure to comply with these instructions may result in damage to the device, îš¿re or other
hazards.
Hazard due to electric shock. Do not operate device without application module.
Hazard due to electric shock. The device is not suited for safe disconnection of the
mains supply. Even when the device is switched off, the load is not galvanically separa-
ted from the mains supply.
Do not connect any non-dimmable lamps, their transformers or operating devices.
Observe manufacturer's data.
Hazard of îš¿re. During operation with conventional transformers, fuse each transformer
on the primary side according to manufacturer's data. Use safety transformers that com-
ply with EN 61558-2-6 (VDE 0570 Part 2-6) only.
These instructions are an integral component of the product and must be retained by the
end user.
2. Design and layout of the device
(3)
(1)
(4)
(7)
(6)
(8)
Figure 1: Universal switch insert 1gang
Universal switch insert 1gang/Universal switch insert 2gang
Page 2/6
6W-5833D 08-2013
(3)
(7)
(6)
(8)
(2)
(5)
Figure 2: Universal switch insert 2gang
(1) Universal switch insert
(2) Universal switch insert 2gang
(3) Frames
(4) Application module
(5) Application module 2gang
(6) Screw for dismantling protection (not R.1/R.3)
(7) Button design cover
(8) Connecting terminals
3. Function
Correct use
–Only suitable for use in indoor areas with no drip and no spray water.
–Switching of incandescent lamps, HV halogen lamps, dimmable energy-saving and 230 V
retroîš¿t LED lamps; electronic and dual-mode transformers or conventional transformers
with low voltage halogen lamps
–Suitable for mixed loads up to the specied total capacity (see "Technical Data")
–Installation into wall box according to DIN 49073 (recommended for touch switch insert
2gang, deep box)
–Operate with suitable aplication module (see "Accessories")
No mixed load operation of capacitive and inductive loads possible at the output.
Product characteristics
–Power extension via universal power boosters (except for switch insert 2gang, see
catalogue)
–automatic setting of load-dependent switching principle and additional, optional settings via
the application module e.g. for energy-saving lamps and 230 V retroîš¿t LED lamps
–Soft start for bulb protection
–Electronic short circuit protection
–Electronic overload and overheating protection
–Electronic interference signal suppression e.g. for ripple control impulses (tariff signals)
–Connection of extension unit push-button (NO contact)
Universal switch insert 1gang/Universal switch insert 2gang
Page 3/6
6W-5833D 08-2013
Additional product characteristics, switch insert 2gang
–Different load types at each output possible
–Output wattage ratings independent from each other
–Possible to operate output 1only
–Connection of extension unit push-button (NO contact) per each output possible
Switching process (table 1)
Do only use dimmable loads.
Flickering of connected lamps possible due to falling below of the indicated minimum load,
ripple control impulses (tariff signals) of power station or illuminant exchange of energy-
savings lamps or 230 V retroîš¿t LED lamps.
Short term ickering during load detection of ohmic loads possible. No operation is possible
during load detection. These are not defects of the device.
If the switching performance of energy-saving lamps and 230 V LED lamps is unsatisfac-
tory in factory setting, a load setting must be carried out. The load setting is described in
the instructions of the respective application module.
When circuiting several loads to one output (parallel circuiting ) optimise switching perfor-
mance via load setting if necessary.
4. Operation
These instructions describe the installation of the switch inserts. The operation is to be taken
from the instructions of the respective application module.
The operation of extension units is only possible if a cover is attached to the main unit.
5. Information for electricians
5.1 Installation and electrical connection
DANGER!
Touching live parts can result in an electric shock.
An electric shock can be lethal.
Disconnect the connecting cables before working on the device and cover all live
parts in the area!
CAUTION!
Do not interconnect the outputs of universal switch insert 2gang.
Operating both outputs on a joint load will destroy the device.
For capacity extension, use universal power boosters (except for universal
switch insert 2gang, see catalogue).
Circuiting and mounting the switch insert
A MCB max. 16 A has been installed as device protection.
Circuit switch insert and optional extension units according to the connection diagram
(Figure 3 to 6).
Mount the switch insert into a wall box. The connecting terminals must be at the bottom.
Attach frame and application module (see instructions for application module).
A deep wall box is recommended for switch insert 2gang.
Illuminated mechanical push-buttons must be equipped with a separate N-terminal.