Bekijk gratis de handleiding van Growatt TPM-6CT-C (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 6 mensen en kreeg gemiddeld 4.5 sterren uit 2 reviews. Heb je een vraag over Growatt TPM-6CT-C of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
ltem
Number
Description
A
1
Three-phase meter
B
1
User manual
1
Rs485 cable (standard length 15m)
D
6
Current transformer (length 6±0.02m)
PIN
1
2
3
4
5
6
7
8
Color
White
orange
(485.B)
Orange
White
green
Blue
White
blue
(485.A)
Green
White
brown
Brown
e. The standard RS485 cable length is 15m.if the length is not enough,please add
another cable to extend the length.The following figure shows the connection between
the meter and the MID-XH/MOD-XH(BP) inverter quick plug terminal.
1
1
1
11.
.
.
..
2
2
2
22.
.
.
..
3
3
3
33.
.
.
..
4
4
4
44.
.
.
..
5
5
5
55.
.
.
..
6
6
6
66.
.
.
..
ABC
TPM-6CT-C(DTSU666)
Three-phase Smart Meter Quick Guide
DTSU666 is a multi-function rail meter, it can accurately measure and display various power parameters in 3P3W/3P4W:voltage,
current, power, frequency, active power, reactive power, forward power, reverse power, total harmonics, etc. The meter is suitable
for real-time power monitoring system, with multi-function, multi-purpose, high stability and long life characteristics. The meter is
connected with an external current transformer and is suitable for various high and low voltage power grids. The meter has RS485
communication interface, supports the highest communication rate of 38400bps, can realize remote communication.
General Specifications
Category
TPM-6CT-C(DTSU666)
Nomianl volatge
3×57.7V/100V3×240V/415V
Nominal current
100A/40mA, 250A/50mA, 100A/333mV,
250A/333mV
Frequency
50/60Hz
Voltage range
0.8Un-1.15Un
Active power
General Specifications
Reactive power
1% of range maximum
Baud rate
1200bps/2400bps/4800bps/9600bps
(default 9600bps)
/19200bps/38400bps/115200bps (optional)
Temperature
-25+55nominal), -40+70ultimate℃~℃~℃()
Way to install
DIN-Rail Mounting
Mounting
dimensions
100x72x65.5mm(LxWxH)
Certification
CESAARoHSREACH
D
72mm
100mm
65.5mm
65.5mm
35.5mm
45mm
LxWxH: 100x72x65.5mm
Three-phase four-wire external current sensor wiring
a. When Growatt inverter products are used in three-phase power grid system, please set “Sensor: Meter” of Growatt inverter as
Sensor: CT.More details, Please refer to the user manual of the corresponding model.
b. Pay attention to distinguish the two groups of CT. The black terminal is connected to the first group of CT, and the green terminal
is connected to the second group of CT. As shown in Figure 1 below.
c. When connecting three-phase energy meter, the CTs on CT1 should be connected to Growatt inverter, and the CTs on CT2 are
connected to the other inverter side. CT direction from grid to load. Please note that the length of the CT wire is 6m. The
installation diagram is shown in Figure 2.
Figure 1
RS485
GRID
Growatt
inverter
Other
inverter
Figure 2
AB
t
he inver
s
id
e
Click!
Note:
1. Be careful the wire of L/N and the range of input voltage or current, if the data is outrange, it may destroy the meter.
2. Be careful where the two CTs are connected.CT1 is connected to the grid side of the growatt inverter, and CT2
is connected to other inverter. Also pay attention to the phase sequence of the CTs. If the CT is connected incorrectly or the phase
sequence is wrong,system will work in a wrong way.
3.Be careful the phase sequence of the voltage sampling side of the meter should correspond to the AC phase sequence of the inverter.
4. If there is no communication (Growatt inverter shows warning 401 or meter communication, indicator is dont display), please check
the communication cable, baud rate, and address.
CT1
CT2
CT2
CT1
d. Connect the RS485A of the LAN line
(White-Blue) to the A terminal labeled
RS485-1 on the meter and RS485B of the
LAN (White-Orange) to the B terminal.
PIN 5 of
LAN line
PIN 1 of
LAN line
(LoadGird)
(GirdLoad)
0.5% of range maximum
LAN line 1-8 colors as below:
From the displayed interface, the electrical parameter and
energy data are all primary side data (that is, the multiplied by
current and voltage ratios). The energy measuring value will
be displayed seven bits, with the displaying range 0.00kWh to
9999999Mwh.