Gossen Metrawatt SECUTEST SIII Handleiding
Gossen Metrawatt
Meetinstrumenten
SECUTEST SIII
Bekijk gratis de handleiding van Gossen Metrawatt SECUTEST SIII (73 pagina’s), behorend tot de categorie Meetinstrumenten. Deze gids werd als nuttig beoordeeld door 11 mensen en kreeg gemiddeld 4.3 sterren uit 6 reviews. Heb je een vraag over Gossen Metrawatt SECUTEST SIII of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/73

SECUTEST SIII+. . .
Test Instruments for Portable Appliance Testing according to Health and Safety Policy
and in Accordance with the Medical Product Law as well as for Routine Testing
3-349-396-03
27/2.21
Operating Instructions
D
e
v
i
c
e
w
i
t
h
o
p
t
i
o
n
a
l
S
I
m
o
d
u
l
e

2 Gossen Metrawatt GmbH
PROBE
54
SONDE
Auto
PE
3
2
HV
Function
Test
V
Aux
Setup
Iso
/
I leakage
BDFHK
AC E G I
Applied Parts
1
!
45678910
11
12
13
14 15 1816 17
Probe connection
Insert the double plug of the probe into sockets 4 and
5 such that the plug with the white ring contacts
socket 5 (vertical bar).
Note: Contact problems with exposed conductive parts
when using the standard probe with test tip
In order to assure good contact, surface coatings must be
removed from devices under test with special tools at a suit-
able location so that the surface has a metallic shine. The tip
of the test probe is not suitable for scratching away paint, be-
cause this may impair its coating and/or mechanical
strength. The brush probe (Z745G) may be more suitable
than the test probe in certain individual cases.
Measurements at jacks 1 – 2 – 3
Always start with the measurement before contacting
the measuring point. Between jacks 1 and 2, a maxi-
mum of 10 V may be applied. Between jacks 2 and 3,
up to 253 V may be applied.
Attention: Jacks (2) and (3) are short-circuited
during all measurements at the test socket!
(Exception: see chapter 12.2)
Standard equipment
1
Test instrument
1 Probe cable with test probe
1 Clip-on alligator clip for test probes
3 Clip-on quick-clamp terminals
1 Calibration certificate per DAkkS
1 Operating instructions
1Carrying strap
Up-to-date PC software (free start-up programs or
demo software for data management, report and list
generation) is available on our website for download.
!
An up-to-date version of the operating instructions
covering the latest firmware update is available for
download on the internet.
RS232
IOIOI
24
23
22
21
25
22
26
27
20
19
max. 10 V
max. 253 V
SL
N
L
1
2
3
—SECULIFE ST
Product specificaties
Merk: | Gossen Metrawatt |
Categorie: | Meetinstrumenten |
Model: | SECUTEST SIII |
Heb je hulp nodig?
Als je hulp nodig hebt met Gossen Metrawatt SECUTEST SIII stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Meetinstrumenten Gossen Metrawatt
1 Augustus 2023
1 Augustus 2023
1 Augustus 2023
1 Augustus 2023
1 Augustus 2023
1 Augustus 2023
1 Augustus 2023
1 Augustus 2023
1 Augustus 2023
1 Augustus 2023
Handleiding Meetinstrumenten
- Psiber
- Perel
- Milwaukee
- Nieaf-Smitt
- Defort
- Myoton
- Scubapro
- Elma
- Max
- AS - Schwabe
- Mercury
- Laserliner
- Greenlee
- GMC Instruments
- Ferrex
Nieuwste handleidingen voor Meetinstrumenten
4 Oktober 2023
4 Oktober 2023
4 Oktober 2023
4 Oktober 2023
4 Oktober 2023
4 Oktober 2023
4 Oktober 2023
4 Oktober 2023
4 Oktober 2023
4 Oktober 2023