Gossen Metrawatt SECUTEST BASE Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Gossen Metrawatt SECUTEST BASE (76 pagina's) in de categorie Meetinstrumenten. Deze handleiding was nuttig voor 13 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/76
Operating Instructions
SECUTEST BASE / PRO und SECULIFE ST BASE
Test Instruments for Measuring the Electrical Safety of Devices
per VDE 0701-0702, IEC 62353 and IEC 60974-4 3-349-752-03
14/ .176
2 GMC-I Messtechnik GmbH
Controls
Connections
These operating instructions describe an instrument with software ersion v FW1.8. .2
Rotary
selector switch
LCD panel
Single measurements
Sequences A1 ... A8, AUTO
(automatic test sequences)
MEM:
Database functions
ESC: Return
Fixed Function Keys
HELP: Help images
START: Start/stop
– Single meas.
– Test sequence
Finger contact
PRINT: Print via USB
Rotary switch level:
Rotary switch level:
Softkeys
Standard
test probe
!
Connection for
service plug only
Lightning symbol:
mains to test socket
!
White identified
and fused high
current path
– For keyboard *
– For barcode/RFID scanner *
– For printer
– For USB drive
Display of symbols for
devices connected to the
USB master interface (see below)
Display of special symbols:
– Measurement at IT system active
– Offset for RPE active
* The receiver must be plugged in here for wireless entry devices.
** is only shown while a connection with another Bluetooth device is active
orange
green
Bluetooth
®
** (Feature M01)
Parameters see page 73
®
*
A list of suitable devices is included in the appendix (see section 14).
No. Meaning
12nd test probe for 2-pole measurement
SECUTEST PRO only (or device with feature H01)
2Voltage measuring inputs
SECUTEST PRO only (or device with feature I01))
3Fuse link for the probe input
4Test probe connection (P1)
5Connection (jack socket) for service plug only!
6Country-specific standard socket (test socket)
for connecting devices under test
7Carrying handle and tilt stand
8Country-specific socket for mains power via inlet
plug
9Fuse link 1 for the mains connection
10 Fuse link 2 for the mains connection
11 Fuse link for 10 A protective conductor test
(additionally with SECUTEST BASE10 (feature G01) or
SECUTEST PRO)
12 USB master for connecting keyboard, barcode/
RFID scanner*, printer* and USB flash drive* (FAT
formatted, not NTFS)
13 USB slave for connection to a PC
3 4 54
6
7
9
10
8
11
12 13
2 21 1 SECULIFE ST BASE (M7050-V101)
corresponds to the range of func-
tions offered by SECUTEST PRO,
but is additionally endowed with
antimicrobial properties.
GMC-I Messtechnik GmbH 3
Overview of Features Included with SECUTEST BASE(10),
PRO and SECULIFE ST BASE Test Instruments
110 A RPE measurements are only possible with line voltages of 115/
230 V and line frequencies of 50/60 Hz.
2Voltage measuring inputs with SECUTEST PRO and SECULIFE ST BASE only
(or instrument with feature I01)
3Connection for 2nd test probe for 2-pole measurement with SECUTEST
PRO and SECULIFE ST BASE only (or instrument with feature H01)
4Measurement of time to trip is not possible in IT systems.
5No checking for reversed polarity takes place when the EL1 adapter is
used.
Key
Alternative = alternative measurement (eq. leakage current meas.)
Differential = differential current measurement
Direct = direct measurement
LN(TS) = short-circuited L and N conductors at test socket
P1 = measurement with test probe P1
P1-P2 = 2-pole measurement with test probes P1 and P2
PE-P1 = measurement between PE and test probe P1
PE(TS) = protective conductor at the test socket
PE(mains) = protective conductor at the mains connection
Differences with Regard to Included Features
* For voltage measurement or for connecting a current clamp sensor, or
an AT3 adapter, and for temperature measurement via RTD
Scope of Delivery
Standard Version (country-specific)
1SECUTEST BASE(10), PRO or SECULIFE ST BASE test instrument
1 Mains power cable
1 Test probe, 2 m, not coiled
1 USB cable, USB A to USB B, 1.0 m long
1 Plug-on alligator clip
1 KS17-ONE cable set for voltage measuring input
(only with
SECUTEST PRO
and
SECULIFE ST BASE
or instrument with
feature I01)
1 Calibration certificate
1 Condensed operating instructions
–
Comprehensive operating instructions available on the Internet
– ETC report software available on the Internet
The most up-to-date version of ETC report generating software
can be downloaded free of charge from the mygmc page of our
website as a ZIP file, if you have registered your test instrument:
http://www.gossenmetrawatt.com
→ Products → Software → Software for Testers
→
Report Soft-
ware without Database
→
ETC
→
myGMC
Attention!
!
The following must be observed if other software packages are
used: ETC report generating software must first be in-
stalled to the PC in order to be able to read out data with
the help of other software packages such as PC.doc-
WORD/EXCEL, PC.doc-ACCESS, ELEKTRO manager and PS3.
Switch
Position
Measuring Function
Test Current/Voltage
Measurement
Type, Connection
Type
Single measurements, rotary switch level: green
RPE
Section
8.5
R
PE Protective conductor resistance PE(TS) - P1 passive
PE(TS) - P1 active
PE(mains) - P1
PE(mains) - P1 clamp
2
P1–P2 3
I
PTest current (200 mA)
SECUTEST BASE10/PRO,
SECULIFE ST BASE: 10 A 1
(feature G01)
RISO
Section
8.6
R
ISO Insulation resistance (PC I/PC II) LN(TS) - PE(TS)
LN(TS) - P1
P1–P2 3
PE(mains) - P1
PE(TS) - P1
LN(TS) - P1//PE(TS)
U
ISO Test voltage
IPE
Section
8.7.1
I
PE Protective conductor current, RMS Direct
Differential
Alternative
AT3-Adapter 2
Clamp 2
I
PE~ AC component
I
PE= DC component
U
LN Test voltage
IB
Section
8.7.2
I
BTouch current, RMS Direct
Differential
Alternative (P1)
Perm. connection
Alternative (P1–P2)
I
B~ AC component
I
B= DC component
U
LN Test voltage
IG
Section
8.7.3
I
GDevice leakage current, RMS Direct
Differential
Alternative
AT3-Adapter 2
Clamp 2
I
G~ AC component
I
G= DC component
U
LN Test voltage
IA
Section
8.7.4
I
A
Leakage current from the applied part, RMS
Direct (P1)
Alternative (P1)
Perm. con. (P1)
U
ATest voltage
IP
Section
8.7.5
I
PPatient leakage current, RMS
Direct (P1)
Perm. con. (P1)
I
P~ AC component
I
P= DC component
U
LN Test voltage
U
Section
8.9
U Probe voltage, RMS P1–P2
P1–P2 (with mains*)
* Polarity param.
U
~ Alternating voltage component
U
= Direct voltage component
U Measuring voltage, RMS 2
V – COM
V – COM (with mains)
U
~ Alternating voltage component 2
U
= Direct voltage component 2
ta 4
Section
8.10
ta
PRCD time to trip for 30 mA PRCDs
U
LN Line voltage at the test socket
P
Section
8.11
Function test at the test socket
Polarity parameter
ICurrent between L and N
UVoltage between L and N
fFrequency
PActive power
SApparent power
PF Power factor
Probe Measuring Functions
EL1
Section
8.12
Extension cord with adapter: continuity, short-circuit,
polarity (wire reversal)
EL1 adapter
AT3-IIIE adapter
VL2E adapter
EXTRA
Section 9
Reserved for expansion during the course of software updates
°C/°F Temperature measurement
2 with Pt100 /
Pt1000
V – COM
Switch
Position
Standard Measurement Type, Connection Type
Automated test sequences, rotary switch level: orange
Preconfigured (freely adjustable) test sequences – default settings
A1
VDE 0701-0702
Passive measurement type, test socket
A2
VDE 0701-0702
Active measurement type, test socket
A3
VDE 0701-0702-EDV
Parametrization for EDP (active)
A4
IEC 62353
(VDE 0751)
Active measurement type
A5
IEC 62353
(VDE 0751)
Active measurement type
A6
IEC 60974-4
Connection type: test socket
A7
IEC 60974-4
Connection type: AT16-DI/AT32-DI
A8
VDE 0701-0702
Extension cord measurement type
(RPE, RISO), adapter:
EL1
/VL2E/
AT3-IIIE
AUTO
VDE 0701-0702
Active measurement type, test socket
Feature SECUTEST BASE
SECUTEST BASE10
SECUTEST PRO
SECULIFE ST BASE
10 A RPE test current • •
Touch-screen keyboard •
2nd test probe •
Voltage meas. inputs *
•
Database expansion
•


Product specificaties

Merk: Gossen Metrawatt
Categorie: Meetinstrumenten
Model: SECUTEST BASE

Heb je hulp nodig?

Als je hulp nodig hebt met Gossen Metrawatt SECUTEST BASE stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetinstrumenten Gossen Metrawatt

Handleiding Meetinstrumenten

Nieuwste handleidingen voor Meetinstrumenten