Gima OXY 100 Handleiding

Gima Medisch OXY 100

Lees hieronder de 📖 handleiding in het Nederlandse voor Gima OXY 100 (22 pagina's) in de categorie Medisch. Deze handleiding was nuttig voor 26 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/22
PROFESSIONAL MEDICAL PRODUCTS
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
gima@gimaitaly.com - export@gimaitaly.com
www.gimaitaly.com
PULSOXIMETRO OXY-100
OXY-100 PULSE OXIMETER
OXYMÈTRE OXY-100
OXÍMETRO OXY-100
OXÍMETRO DE PULSO OXY-100
Manuale d’uso - User manual
Manuel de l’utilisateur
Guía de uso - Guia para utilização
ATTENZIONE: Gli operatori devono leggere
e capire completamente questo manuale
prima di utilizzare il prodotto.
ATTENTION: The operators must carefully read
and completely understand the present manual
before using the product.
AVIS: Les opérateurs doivent lire et bien
comprendre ce manuel avant d’utiliser le produit.
ATENCIÓN: Los operadores tienen que leer y entender
completamente este manual antes de utilizar el producto.
ATENÇÃO: Os operadores devem ler e entender
completamente este manual antes de usar o produto.
M34342-M-Rev.4-02.19
Gima S.p.A.
Via Marconi, 1
20060 Gessate (MI) Italy
Made in China
34342 0476
23 ENGLISH
Instructions for Safe Operation
- Check the device to make sure that there is no visible damage that may
aect user’s safety and measurement performance. It is recommended that
the device should be inspected minimally before each use. If there is obvious
damage, stop using the device.
- Necessary service must be performed only by qualied technicians. Users
are not permitted to service this device.
- The oximeter must not be used with the devices and accessories not specied
in User Manual.
Cautions
- Explosive hazard—DO NOT use the oximeter in environment with inammable
gas such as some ignitable anesthetic agents.
- DO NOT use the oximeter while the Patient is under MRI or CT scanning.
This device is NOT MRI Compatible.
Warnings
- Discomfortable or pain may occur if using the sensor of this device
continuously on the same location for a long time, especially for the patients
with poor microcirculation. It is recommended that the Oximeter should not be
applied to the same location for longer than 2 hours or less if any abnormal
condition is found. Frequently check and re-position the Oximeter.
- For the individual patients, there should be a more prudent inspecting in the
placing process. The sensor can not be placed on the edema and tender tissue.
- The local law should be followed when disposing of the expired device or
its accessories.
Attentions
- Keep the oximeter away from dust, vibration, corrosive substances, explosive
materials, high temperature and moisture.
- If the Oximeter gets wet, please stop operating it and do not resume operation
until it is dry and checked for correct operation. When it is carried from a cold
environment to a warm and humid environment, please do not use it immediately.
Allow at least 15 minutes for the Oximeter to reach ambient temperature.
- DO NOT operate the button on the front panel with sharp materials or sharp point.
- DO NOT use high temperature or high pressure steam disinfection on the
oximeter and probes. Refer to related chapter for instructions regarding
cleaning and disinfection.
- The intended use of this device is not for therapy purpose.
24
1 Overview
1.1 Appearance
Figura 1-1
DC power inputData interface
Display screen
Navigation key
Mode / OK
SpO2 probe
connector
Power / Back
Recall / Mute
1. Display screen: display SpO2 plethysmogram and parameter values.
2. Navigation key:
: Up/Left/Increase
Press this key, the default screen can be shifted to display pulse rate (PR) or
perfusion index (PI). If on the system setup screen, press it to move the cursor
upwards or to the left and adjust parameter values.
: Down/Right/Decrease
Its function is similar with the key “ : Up/Left/Increase”.
3. (Mode/OK): press this key, the screen can be shifted between default
screen display and alternative screen display; longtime press it, the menu
ENGLISH


Product specificaties

Merk: Gima
Categorie: Medisch
Model: OXY 100

Heb je hulp nodig?

Als je hulp nodig hebt met Gima OXY 100 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden