Gaggenau VL414115 Handleiding

Gaggenau Fornuis VL414115

Lees hieronder de 📖 handleiding in het Nederlandse voor Gaggenau VL414115 (32 pagina's) in de categorie Fornuis. Deze handleiding was nuttig voor 20 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/32
en User manual and installation instructions
VL414115
Extractor hood
Gaggenau
en Safety
2
Table of contents
INFORMATION FOR USE
1 Safety...................................................................2
2 Avoiding material damage..................................4
3 Environmental protection and saving en-
ergy ......................................................................5
4 Operating modes ................................................5
5 Familiarising yourself with your appliance .......6
6 Accessories.........................................................7
7 Before using for the first time ............................7
8 Basic operation ...................................................7
9 HomeConnect ....................................................8
10 Connecting the downdraft ventilation to the
hob .....................................................................14
11 Basic settings....................................................15
12 Cleaning and servicing.....................................17
13 Troubleshooting................................................18
14 Customer Service..............................................20
15 Disposal.............................................................20
16 Declaration of Conformity ................................21
17 INSTALLATION INSTRUCTIONS ......................21
17.3 Secure installation ............................................22
1 Safety
Observe the following safety instructions.
1.1 General information
¡Read this instruction manual carefully.
¡Keep the instruction manual and the
product information safe for future refer-
ence or for the next owner.
¡Do not connect the appliance if it has been
damaged in transit.
1.2 Intended use
This appliance is designed only to be built
into kitchen units. Read the special installation
instructions.
The appliance can only be used safely if it is
correctly installed according to the safety in-
structions. The installer is responsible for en-
suring that the appliance works perfectly at its
installation location.
Only use this appliance:
¡For extracting cooking vapour.
¡in private households and in enclosed
spaces in a domestic environment.
¡up to an altitude of max. 4000m above
sea level.
Do not use the appliance:
¡With an external timer.
¡To extract hazardous or explosive sub-
stances and vapours.
¡To extract small parts and liquids.
1.3 Restriction on user group
This appliance may be used by children aged
8 or over and by people who have reduced
physical, sensory or mental abilities or inad-
equate experience and/or knowledge,
provided that they are supervised or have
been instructed on how to use the appliance
safely and have understood the resulting
dangers.
Do not let children play with the appliance.
Children must not perform cleaning or user
maintenance unless they are at least 15 years
old and are being supervised.
Keep children under the age of 8 years away
from the appliance and power cable.
1.4 Safe use
WARNING‒Risk of fire!
The downdraft ventilation may draw in the
flame from gas burners. The grease deposits
in the grease filter may catch fire. Small
flames may go out.
â–¶If you are operating the downdraft ventila-
tion next to a gas-fired appliance, fit the
ventilation moulding on the gas-fired appli-
ance. The ventilation moulding prevents the
downdraft ventilation from drawing in
flames.
Safety en
3
WARNING‒Risk of suffocation!
Children may put packaging material over
their heads or wrap themselves up in it and
suffocate.
â–¶Keep packaging material away from chil-
dren.
â–¶Do not let children play with packaging ma-
terial.
Children may breathe in or swallow small
parts, causing them to suffocate.
â–¶Keep small parts away from children.
â–¶Do not let children play with small parts.
WARNING‒Risk of poisoning!
Risk of poisoning from flue gases being
drawn back in. Room-air-dependent heat-pro-
ducing appliances (e.g. gas, oil, wood or coal-
operated heaters, continuous flow heaters or
water heaters) obtain combustion air from the
room in which they are installed and dis-
charge the exhaust gases into the open
through an exhaust gas system (e.g. a chim-
ney). With the extractor hood switched on, air
is extracted from the kitchen and the adjacent
rooms. Without an adequate supply of air, the
air pressure falls below atmospheric pressure.
Toxic gases from the chimney or the extrac-
tion shaft are sucked back into the living
space.
â–¶Always ensure adequate fresh air in the
room if the appliance is being operated in
exhaust air mode at the same time as a
room-air-dependent heat-producing appli-
ance is being operated.
â–¶It is only possible to safely operate the ap-
pliance if the pressure in the room in which
the heating appliance is installed does not
fall below 4Pa(0.04mbar). This can be
achieved whenever the air needed for com-
bustion is able to enter through openings
that cannot be sealed, for example in
doors, windows, incoming/exhaust air wall
boxes or by other technical means. An in-
coming/exhaust air wall box alone is not
sufficient to ensure compliance with the
limit.
â–¶In any case, consult your responsible chim-
ney sweep. They are able to assess the
house's entire ventilation setup and will
suggest the suitable ventilation measures
to you.
WARNING‒Risk of fire!
Fatty deposits in the grease filters may catch
fire.
â–¶Never operate the appliance without a
grease filter.
â–¶Clean the grease filters regularly.


Product specificaties