Symbol ValueUnitSymbol ValueUnit
Prated,c 15.1 kWηs,c 215.8 %
Pdc15.10kW EERd2.72 䇷
Pdc11.13kW EERd4.63 䇷
Pdc7.15kW EERd6.17 䇷
Pdc 4.79kWEERd9.79 䇷
Cdc 0.25 䇷―――
POFF 0.010 kWPCK 0.023 kW
PTO 0.023 kWPSB 0.010 kW
Prated,h 15.1 kWηs,h 156.6 %
Pdh10.44kW COP
d2.37 䇷
Pdh6.35kW COP
d3.62 䇷
Pdh4.08kW COP
d6.35 䇷
Pdh3.88kW COP
d8.10 䇷
Pdh10.44kW COP
d2.37 䇷
Pdh7.97kW COP
d2.01 䇷
Tbiv -7 °C
Cdh 0.25 䇷
POFF 0.017 kWelbu1.93kW
PTO 0.040 kW
PCK 0.023 kWPSB 0.017 kW
2088
kg CO2eq
(100 years)
Cooling LWA 52.0 / 70.0dBCooling4400 m³/h
Heating LWA 52.0 / 70.0dBHeating4400 m³/h
Declared cooling capacity for part load at given outdoor
temperatures Tj and indoor 27°/19 °C (dry/wet bulb)
Declared energy efficiency ratio for part load at given outdoor
temperatures Tj
[1] Information sheet (Lot.21)
[2] This information includes the results of calculation of the seasonal energy consumption and efficiency for air conditioner in regards
to ErP pursuant to the Commission Regulation(EU) 2016/2281.
Outdoor unit / Indoor unit
Outdoor side heat exchanger of air conditioner
Indoor side heat exchanger of air conditioner
Compressor type / driver of compressor
Vapour compression / Electric motor
Cooling
Item
Item
Rated cooling capacity
Seasonal space cooling energy
efficiency
AJ*054LCLDH / AUXB012GLEH ×3 + AUXB014GLEH ×1
Tj = + 35 ºC
Tj = + 35 ºC
Tj = + 30 °C
Tj = + 30 ºC
Tj = + 25 °C
Tj = + 25 ºC
Declared heating capacity for part load at indoor temperature
20 °C and outdoor temperature Tj
Declared coefficient of performance for part load at given
outdoor temperatures Tj
Tj = + 20 °C
Tj = + 20 ºC
Degradation co-efficient for air
conditioners
―
Power consumption in modes other than ‘active mode’
Off mode
Crankcase heater mode
Thermostat-off mode
Standby mode
Heating
Rated heating capacity
Seasonal space heating energy
efficiency
Tj = – 7 °C
Tj = – 7 °C
Tj = + 2 °C
Tj = + 2 °C
Tj = + 7 °C
Tj = + 7 °C
Tj = + 12 °C
Tj = + 12 °C
Tbiv = bivalent temperature
Tbiv = bivalent temperature
TOL = operation limit
TOL = operation limit
Bivalent temperature
䇷
䇷
䇷
䇷
Degradation co-efficient heat
pumps
Power consumption in modes other than ‘active mode’
Supplementary heater
Off mode
Back-up heating capacity
Thermostat-off mode
Type of energy input
Electricity
FUJITSU GENERAL LIMITED
3-3-17,Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan
* Please refer to the last page for translation to other languages.
PART No. 9384138828-01
Crankcase heater mode
Standby mode
Other items
Capacity control
Variable
Air flow rate,
outdoor measured
GWP of the refrigerant
Sound power level
(Indoor unit /
Outdoor unit)
Contact details
V20170928
Alle foutcodes Fujitsu Airco 160 foutcodes uit 106 handleidingen, met hun betekenis.
Product specificaties
| Merk: | Fujitsu |
| Categorie: | Airco |
| Model: | AJH054LCLDH |
Heb je hulp nodig?
Als je hulp nodig hebt met Fujitsu AJH054LCLDH stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airco Fujitsu
Fujitsu Lifestyle ASTG30CMTA Handleiding Fujitsu AUTA30LBLU Handleiding Fujitsu Airstage AUXV014GLEH Handleiding Fujitsu Airstage AGHE012GCEH Handleiding Fujitsu Airstage AGYA012GCEH Handleiding Fujitsu Airstage AJY054LBLAH Handleiding Fujitsu Lifestyle ASTG30KMTA Handleiding Fujitsu Airstage AJY040LELAH Handleiding
Alle Fujitsu Airco handleidingen