Bekijk gratis de handleiding van Franke HWF23 (12 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 4 mensen en kreeg gemiddeld 4.7 sterren uit 2.5 reviews. Heb je een vraag over Franke HWF23 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/12

1
02/22 | OZOZMI-02-2022 | OZO-FLO FAUCET installation
a) Install the faucet onto the sink or wall
b) Determine the optimum location for the
wall housing - under or near the sink.
Ensure that cable connections can be
made.
c) Using the white wall plate as a template,
mark the screw hole locations (4)
d) Using hardware appropriate for the
installation wall, place the white backing
plate behind the stainless steel plate
and secure to the wall.
e) Use a standard 1/2" braided faucet
supply hose, connect this to the brass
threaded inlet of the solenoid valve.
OZO-FLO FAUCET AND HOUSING
INSTALLATION
INSTRUCTIONS FOR HWF05, HWF23, HWF43
Figure D.jpg
Figure C.jpg
Preface
Ozonated water has been proven as a safe and extremely effective way to help sanitize the sink and keep the drain and trap free of CPOs
and other pathogens. This also improves the efficiency of hand washing. Other control features include a post-wash cycle of 3 seconds
which ensures all soap residue and bacteria has been washed down the sink, and a daily purge cycle to prevent stagnant water in the lines
and ensure continuouswaste disinfection. Any standard P-trap will be disinfected with this process.
Ozo-flo has been exclusively designed for sinks intended for hand washing only. It is not recommended as a drinking source. Recommend-
ed for areas with normal water conductivity in the range of 75 - 350 total dissolved solids (TDS). If unaware of your local water conductiv-
ity, please contact customer service and this can easily be determined for you before you install the product.
Ozo-flo is recommended to be installed with a thermostatic mixing valve and set to a temperature of 27-35C. (Optional accessory MEDI-
MIX is available from Franke).
INSTRUCTIONS:
Figure E.jpg

2
02/22 | OZOZMI-02-2022 | OZO-FLO FAUCET installation
f) If necessary connect the 5.1mm
extension cable to the control board.
Figure F.jpg
g) Pass the other end to the supply hose
through the hole in the bottom of the
shroud. Mark and drill the wall which will
later be used to secure the shroud to the
wall.
h) Connect the ½" supply hose from the
bottom of the faucet to the top of the
Ozo-flo housing. Do not over-tighten
(hand tighten plus 1/4 turn).
Figure H.jpg
i) Make note of the red and yellow colour
markings of the electrical connectors
and match them with the bands on the
cables coming from the faucet. The
connectors are keyed and will only push
together one way. Gently push and rotate
the connection until they assemble and
screw closed.
j) Plug in the power supply, wait 10
seconds and activate the faucet. It may
take 10 seconds for the ozonation
chamber to fill with water and then come
through the faucet.
k) Check for any leaks and proper oper-
ation. Once checked, complete the
assembly by securing the shroud to the
wall.
TESTING
When the faucet is activated, water should flow and the blue ring on
the tap will illuminate. When you remove your hands the tap will stop
water flow and start its lathering timer. During this time the LED ring
will pulse in intensity. During this timed operation, the concentration
of ozone and other mixed oxidants are building in the chamber. The
faucet will slowly drip from the spout. This is normal as the volume in
the chamber is increasing due to the oxidant generation. At the end
of the lathering timer (default 20 seconds), the tap will automatically
run for 3 seconds. This 3-second run time has two purposes.
a) Can be used as a timer for users to ensure they have lathered to
the recommended time.
b) It helps rinse any remaining soap residue in the sink away after a
user has walked away.
TROUBLESHOOTING
Ozo-flo will briefly release traces of ozonated water post-usage (as
part of the ozonation purge cycle). An additional factory set purge
cycle will activate once every 24 hours. The timing can be modified
using our optional hand-held programmer (part number AC01-005).
No water flow - Ensure power is connected and you have water
supply pressure. When you trigger the tap by placing your hands
underneath, you should see the LED ring illuminate. If the LED does
not illuminate check to see that the wire connections from the tap to
the wall housing are correct (match colour red and yellow bands on
the cable). If the LED illuminates and no water flow check to see that
the spade connectors are properly installed on the solenoid valve
located inside the wall housing. The brown wire should be closest to
the wall. If these wires are not connected, the solenoid will not func-
tion. You should hear a click of the solenoid valve when triggered. If

Franke Kindred Canada Limited
1000 Franke Kindred Road
Midland, ON L4R 4K9
Tel 1.855.446.5663
Fax 1-866-227-3050
www.franke-commercial.com
02/22 | OZOZMI-02-2022 | OZO-FLO FAUCET installation
The automatic faucet spout, cables and Power Supply Unit (PSU) is guaranteed for 2 years from purchase against defective ma-
terial and assembly. The solenoid valve is guaranteed for 12 months, subject to water condition, however it is expected that the valve mecha-
nism will operate efficiently for many years.
WARRANTY
the valve is not triggering and power and connections are validated,
replace solenoid valve with part number AC17-104.
Water triggers but does not stop - Ensure that the range setting
for distance is properly set for the faucet. Use handheld programmer
part number AC01-005 (sold separately) to adjust range or contact
your local rep.
LED blinking once per second - This indicates that the output of
the ozone generator is low. Verify that the ozone chamber is filled
with water. When activated you should see bubbles being generated.
Verify that the ozone generator cable is connected (blue banded
cable). Otherwise verify your local water TDS. Ozo-flo is recommend-
ed for water above TDS of 75.
LED blinking 2x per second - This indicates the ozone generator
is drawing too much current and the system has shut off power for
protection. Inspect ozone generator for a short between the mesh
plates. Verify your local water TDS is not above 400. If you have high
TDS contact our customer service and we can assist with proper
generator sizing.
Tap Dripping - When the ozone generator is charging the canister,
traces of ozonated water will be released from the tap. This is normal
operation and will only occurr when the LED is pulsing in intensity
(for approximately 90 seconds). If the dripping is constant, the so-
lenoid valve may have debris on its internal seal/seat. The solenoid
may be disassembled for cleaning or you may order a replacement
(part number AC17-104)
OZONE GENERATOR TECHNICAL INFORMATION
The ozone generator within Ozo-flo not only generates ozone but
also other powerful oxidants such as oxygen atoms, (O2 ), hydrogen
peroxide and hydroxyl radicals which all work together to destroy
harmful bacteria and viruses.
The residual ozone (O3 ) & mixed oxidants produced by the system is
a function of water flow rate, the water conductivity (TDS) and water
composition. In other words, residual ozone is a function of the water
composition (such as hardness, alkalinity, PH, iron, manganese,
colour, odour, bacteria, etc.) and the flow rate (or length of time the
generator is running with no flow rate during the lather time or during
trap purge disinfection cycle). The mix of produced ozone and other
mixed radicals is also dependent on local water conditions.
For optimum performance, we recommend installation in areas with
conductivity between 75-350TDS. If below 75TDS, the ozone genera-
tor will still function down to as low as TDS of 50; however, oxidant
output may be reduced to under 0.5ppm. In areas above 350TDS,
we may recommend a smaller ozone generator as to not max out the
power supply. TDS can be measured using a small TDS reader, your
local water or pool supply store or by sending in a sample of 250ml
minimum to our customer service.
We recommend the DPD test to measure ozone generator output as
it also takes into consideration the additional mixed oxidant poten-
tial. Tests such as ORP and Indigo may not give valid readings due
to hydrogen interference, temperature, water composition and PH.
Subtract the reading obtained from straight tap water to remove any
reading from chlorine.
The default operation of the ozone generator is to run a charge cycle
after every use. Target canister charge is 2.0ppm of mixed oxidants.
During this charge cycle, you will see the LED pulse in intensity (this can
be adjusted or turned off with the handheld programmer AC01-005)
Typical approximate output is as follows:
@150 TDS =17minutes @200 TDS =12 minutes
@250 TDS =7 minutes @300 TDS = 4 minutes
@350 TDS =3 minutes
During a hand wash cycle, when the initial signal is received to wash
hands, the user typically wets their hands and then commences
lathering. While they pull away their hands to lather, the water flow
will stop but we keep the ozone generator running for 20 seconds to
build up concentration in the chamber to be available for the rinse
cycle. Alternatively, after 20 seconds of last use the water flow will
automatically come on for an additional 3 seconds. The intention is
that 20 seconds after last use, the sink will dispense a small amount
of water for a post-rinse clean of the sink and trap to remove any
remaining soap residue.
Note: Water softeners will increase TDS and are recommended
if your conductivity is low; however, reverse osmosis or de-ionized
water is not compatible with Ozo-flo.
Product specificaties
Merk: | Franke |
Categorie: | Niet gecategoriseerd |
Model: | HWF23 |
Heb je hulp nodig?
Als je hulp nodig hebt met Franke HWF23 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Franke
23 Mei 2025
12 Mei 2025
16 April 2025
16 April 2025
16 April 2025
16 April 2025
16 April 2025
8 April 2025
18 December 2024
3 December 2024
Handleiding Niet gecategoriseerd
- Datalogic
- Fosi Audio
- BZBGear
- American BioTech Supply
- Hatco
- Fresca
- Suevia
- Rosseto
- Kiloview
- Continental Edison
- Sparkle
- Accucold
- Hortus
- Hagor
- Hasselblad
Nieuwste handleidingen voor Niet gecategoriseerd
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
18 Juni 2025