Power Button – The Scout III has three power states: On, Off, and Auto Shutdown.
• On – Takes approximately 4 seconds (during bootup the FLIR splash screen
appears on the eyepiece display).
• Off – Push the power button to turn the camera off.
• Auto Shutdown - If no buttons are pushed for about ve minutes,
Auto shutdown 30s appears in the display and after counting down for
30 seconds, the camera will turn off.
Display Brightness – If camera is on, press to toggle through 5 brightness settings.
White/Black Hot/InstAlert™/Graded Fire – In White Hot, hotter items appear as
white or light grey. In Black Hot, hotter items appear as black or dark grey. In InstAlertâ„¢,
hot items in a scene are highlighted in red. In Graded Fire, hot items in a scene are
highlighted in yellow with enhanced detail.
Zoom/Freeze Frame – A quick press causes the image to toggle between 1x and
2x zoom on the 320 camera and 1x, 2x, and 4x on the 640 camera. With the 240
camera, the zoom button freezes the image with one click and unfreezes the image
with a second click.
Diopter Controls – The diopter allows adjustment of the eyepiece for optimal viewing.
SCOUT III
Q uick St ar t G u id e
Power
Task Light Mini-USB/Charging/Analog
video out (320 & 640 models only)
Display Brightness
Task Light On/Off
White/Black Hot
InstAlertâ„¢
Graded Fire
Zoom 320 & 640 / Freeze Frame 240
Charging
Indicator
Eyepiece
Adjustable Diopter
To charge the camera, lift the cover from the
mini-USB port, plug in the mini-USB cable
provided with the camera, then plug the
opposite end into a USB power source.
• Charging correctly – indicator lit orange.
• Fully charged – indicator lit solid green.
• While the camera is on, a battery status
indicator always appears in the corner of
the display image. This indicator provides an
estimation of the remaining battery charge.
Charging the Camera – The battery in the camera should be fully charged prior to
use. The initial charge time is approximately 4 hours. The camera MUST be turned OFF
throughout the charging cycle to obtain a full charge.
Caution! – Charging MUST only be done at temperatures from 0°C to 40°C
(32°F to 104°F) or battery damage may occur.
Mini-USB/Video Adapter Cable
To obtain analog video out (320 & 640
models only), insert the adapter cable into
the mini-USB connector. The camera will
detect the adapter cable and provide the
video stream. Use an RCA cable to connect
to a monitor or a video recorder.
Register your camera now at: www.ir.com/scout/registration
For warranty information, visit: www.ir.com/scout/warranty
Diopter Controls
The diopter adjustment lever allows
you to adjust for optimum image
sharpness in the eyepiece. When the
diopter adjustment lever is pointing
straight away from the front of the
camera, it is in the neutral position.
Adjust the diopter setting for the
sharpest image in the viewnder.
Equipment described herein requires US Government authorization for export purposes.
Diversion contrary to US law is prohibited. Questions regarding export controls contact: exportquestions@ir.com
QRC 4205353 Rev 1


Product specificaties

Merk: Flir
Categorie: Thermometer
Model: Scout III-320

Heb je hulp nodig?

Als je hulp nodig hebt met Flir Scout III-320 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermometer Flir

Handleiding Thermometer

Nieuwste handleidingen voor Thermometer