Festo NEFM-REG6-K-0.5-B-REG6 Handleiding

Festo Niet gecategoriseerd NEFM-REG6-K-0.5-B-REG6

Bekijk gratis de handleiding van Festo NEFM-REG6-K-0.5-B-REG6 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.3 sterren uit 1.5 reviews. Heb je een vraag over Festo NEFM-REG6-K-0.5-B-REG6 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
NEFM-REG6-K-...-B-REG6
Adapter
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Deutschland
+49 711 347-0
Assembly instructions
8164713
2021-10b
[8164715]
Translation of the original instructions
© 2021 all rights reserved to Festo SE & Co. KG
SAFT®, TOSHIBA®, maxell® are registered trademarks of the respective trade-
mark owners in certain countries.
1
Applicable documents
All available documents for the product
è
www.festo.com/sp.
Document Product
User documents Servo motor EMMB-AS
User documents Servo drive CMMB-AS
Tab. 1
2 Safety
2.1
Safety instructions
Only mount the product on components that are in a condition to be safely
operated.
2.2 Intended use
The adapter connects a servo motor EMMB-AS (with multiturn encoder) with a
servo drive CMMB-AS.
2.3 Training of qualified personnel
Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers. The qualified personnel are trained in
electrical engineering.
3 Structure
3.1 Product design
1
2
3
4
Fig.1
1
Socket
2
Battery housing
3
Cable
4
Plug
3.2 Recommended batteries; not in scope of delivery
5
Fig.2
5
Battery with
socket JAE IL-2S-S3L-(N)
Battery 5
5
5
55
TOSHIBA
ER6V
SAFT
LS14500
maxell
ER6C
Voltage [V] 3.6 3.6 3.6
Capacity [mAh] 2000 2600 1800
Maximum diameter [mm] 14.6 15 14.5
Maximum length (incl.
connections)
[mm] 52 54.8 51
Service life (approx.) [a] 2.2 3 2
Tab. 2: Specification of the battery
3.3
Contact assignment
Electrical connection 1
Field device side
Electrical connection 2
Controller side
1 Socket Pin Allocation/
Signal
Allocation/
Signal
Pin Plug con-4
nector
1 +5V 5
2 GND 2
3 BAT+ Not assigned 3
4 BAT– Not assigned 1
5 SD 4
6 /SD 6
Tab. 3: Contact assignment
4 Assembly
4.1 Installation of the battery
The battery can be installed with the adapter plugged in.
Shut off the controller release on the servo drive.
A
B
2
Fig. 3:
Opening battery housing
1.
Align the battery housing so the labelling is legible.2
2.
Press in the centre of the bottom part [B] and lift the cover [A] at the same
time.
3.
Remove the top part [A].
4. Remove the bottom part [B].
X
Fig. 4:
Checking contact assignment
Check the contact assignment of the socket (X) of the battery and correct if5
necessary.
5
X
Fig. 5:
Attaching push-in connector
Wire the battery with push-in connector.5
5
A
B
G
Fig. 6: Closing battery housing
1. Insert the battery and push-in connector into the bottom part [B].5
2. Position the top part [A] and engage it. Do not pinch wires [G].
4.2 Mounting electrical connection 1
1. Align the socket to fit the plug.1
2. Connect the socket to the plug.1
Ä
Plug audibly engages.
4.3 Mounting electrical connection 2
1.
Align the plug to match the socket.4
2. Insert the plug into the socket.4
Ä
The plug audibly engages.
5 Replacement of the battery
The battery can also be replaced when the machine is switched on and the
adapter is plugged in.
If possible, replace the battery within 10 seconds. If the replacement takes longer,
the servo motor switches to the "Not referenced" status and the saved absolute
position is deleted. Reference the axis again, if necessary.
The life of the battery depends on the frequency of use. The service life is reduced
the more often the machine/system is switched off and the absolute position of
the servo motor has to be maintained via the battery.
Shut off the controller release on the servo drive.
A
B
2
Fig. 7:
Opening battery housing
1.
Align the battery housing so the labelling is legible.2
2.
Press in the centre of the bottom part [B] and lift the cover [A] at the same
time.
3.
Remove the top part [A].
4.
Remove the bottom part [B].
E
Fig. 8:
Disconnecting push-in connector
1. Pull apart the push-in connector.
2.
Dispose of battery [E] in an environmentally friendly manner.
3. Install the new battery 5
è
4.1 Installation of the battery.
6 Technical data
NEFM-REG6-K-...-B-REG6
Cable characteristic Standard
Cable composition [mm²] 4x2x0.081 + 1x2x0.205
Shielding Shielded
Cable diameter D [mm] 6.8
Current rating at 40 °C [A] 1.6
Surge resistance [kV] 2
Operating voltage range
AC U
B
[V] 0 … 30
DC U
B
[V] 0 … 30
Bending radius
Fixed cable installation R [mm] 68³
Ambient temperature
Fixed cable installation [°C] –40 … +80
Material
Cable sheath PVC
Insulating sheath PVC [SR-PVC]
Electrical connection 1
Function Field device side
Connection type Socket
Connection technology Plug pattern RE
Degree of protection IP20 In assembled state
Electrical connection 2
Function Controller side
Connection type Plug connector
Connection technology Plug pattern RE
Degree of protection IP20 In assembled state
Tab. 4: Technical data


Product specificaties

Merk: Festo
Categorie: Niet gecategoriseerd
Model: NEFM-REG6-K-0.5-B-REG6