Bekijk gratis de handleiding van Festo NEBL-T12W4-E-5-N-LE4 (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 5.0 sterren uit 1.5 reviews. Heb je een vraag over Festo NEBL-T12W4-E-5-N-LE4 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
6.
8.
NEBL-T12...4-E-...-LE4
Connecting cable
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
Assembly instructions
8187643
2023-03a
[8187645]
8187643
Translation of the original instructions
© 2023 all rights reserved to Festo SE & Co. KG
1
Applicable documents
All available documents for the product
è
www.festo.com/sp.
2 Safety
2.1
Safety instructions
Do not connect or disconnect the push-in connector while the voltage is live.
Do not wire or disconnect an open cable end when powered.
Only mount the product on components that are in a condition to be safely
operated.
2.2 Intended use
The connecting cable connects electric drives to the power supply at the M12T-
coded plug.
2.3
Training of qualified personnel
Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers. The qualified personnel are trained in
electrical engineering.
3 Additional information
Accessories
è
www.festo.com/catalogue.
4 Structure
4.1
1 23
Fig. 1:
NEBL-T12G4-E-...-LE4
1
Socket M12x1, T-coded
2
Core (4x)
3
Cable
1 23
Fig. 2:
NEBL-T12W4-E-...-LE4
1
Socket M12x1, T-coded
2
Core (4x)
3
Cable
4.2 Contact assignment
Electrical connection1
Field device side
Insulated wire
1)
Electrical connection2
Controller side
1 BN Open end
2 WH
3 BU
4 BK
1)
Colour code in accordance with IEC 60757:2021-06
Tab. 1: Contact assignment
5 Assembly
5.1 Assembly, field device side
1. Align the socket to fit the plug.1
2. Connect the socket to the plug.1
3. Tighten the screw-type lock of the socket . Tightening1
torque:0.4Nm±55%
5.2
Assembly, controller side
1. Strip and assemble the cable sheath and insulated wires as required.
2.
Connect the insulated wires in accordance with the contact assignment.
5.3
Wiring
Character-
istic
Cable characteristic Wiring
-E Suitable for energy chains In energy chain or flexible
Tab. 2: Wiring
5.4
Strain relief
Strain relief for movable wiring:
Fix the cable sheath in the area of the wire ends.
Ä
The insulated wires must not be subjected to force.
5.5
Mounting in energy chain
1. Lay out the energy chain lengthways.
2. Place the cables in the energy chain without twisting them.
3. Separate cables from each other using separators/drilled holes.
4.
Do not bind cables in bundles.
5.
Maintain spaceX. X 10%of the cable diameterD.>
With the energy chain hanging vertically: increase the spaceX.
Align the energy chain in the working position:
Make sure that the radius is greater than the bending radiusR of the
cables.
The cables can move freely in the bending radius KR of the energy chain.
Ä
The cable movement is not forced by the energy chain.
7.
Mount the energy chain corresponding instruction manual.è
Fasten the cables:
for short energy chains with a length 1m at both ends of the energy<
chain
for long sliding energy chains with a length 1m at the driver end only>
9.
Do not move cables all the way to the fastening point.
Ä
The mounting spaceA between the fastening point and bending move-
ment is maintained.
NOTICE
Damage to cables if the chain breaks.
Replace cables after a chain break.
NOTICE
Malfunction and material damage due to vertically suspended cables.
The cables stretch.
Regularly check the length of the cables.
Readjust the cables if required.
6 Technical data
NEBL-T12...4-E-...-LE4
Certificates, declaration of conformity
è
www.festo.com/sp
Cable characteristic Suitable for energy chains
Cable composition [mm²] 4x1.5
Shielding No
Cable diameter D [mm] 8.4
Mounting space A [mm] 168³
Current rating at 40°C [A] 12
Surge resistance [kV] 1.5
Operating voltage rangeDC U
B
[V] 0…63
Bending radius
Fixed cable installation R [mm] 42³
Flexible cable installation R [mm] 84³
Ambient temperature
Fixed cable installation [°C] –25…+80
Flexible cable installation [°C] –25…+80
Material
Cable sheath TPE-U(PUR)
Insulating sheath PP
Electrical connection1
Function Field device side
Connection type Socket
Connection technology M12x1 T-coded in accordance with
EN61076-2-111
Type of mounting Screw-type lock
Degree of protection In assembled
state
IP65, IP67
Electrical connection2
Function Controller side
Connection type Cable
Connection technology Open end
Wire ends Sheath removed
Tab. 3: Technical data


Product specificaties

Merk: Festo
Categorie: Niet gecategoriseerd
Model: NEBL-T12W4-E-5-N-LE4

Heb je hulp nodig?

Als je hulp nodig hebt met Festo NEBL-T12W4-E-5-N-LE4 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden