Festo MS4-EM1FR-1/4-D6-C-P-VC-AG-MPA-WPE-B Handleiding

Festo Niet gecategoriseerd MS4-EM1FR-1/4-D6-C-P-VC-AG-MPA-WPE-B

Bekijk gratis de handleiding van Festo MS4-EM1FR-1/4-D6-C-P-VC-AG-MPA-WPE-B (2 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.8 sterren uit 1.5 reviews. Heb je een vraag over Festo MS4-EM1FR-1/4-D6-C-P-VC-AG-MPA-WPE-B of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
MS4-EM1FR-...-B
Service unit
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
8195515
2023-05a
[8195517]
8195515
Translation of the original instructions
© 2023 all rights reserved to Festo SE & Co. KG
1
Applicable documents
All available documents for the product
è
www.festo.com/sp.
Document Product Content
Operating instruction Filter regulator MS4-LFR-...-B
Assembly instructions Wall mounting kit MS4-WPE(-B)
Tab. 1:
Applicable documents
2 Safety
2.1
Safety instructions
Only use the product in its original condition without unauthorised modifica-
tions.
Only use the product if it is in perfect technical condition.
Observe the identifications on the product.
Take into account the ambient conditions at the location of use.
Before working on the product, switch off the compressed air supply and lock it
to prevent it from being switched on again.
2.2 Intended use
The on-off valve pressurises and exhausts pneumatic systems. The on/off valve
is not suitable for continuous switching operation for pneumatic components.
The filter regulator controls the compressed air in the downstream string at
the set outlet pressure. The filter regulator smooths pressure fluctuations and
removes dirt particles and condensate from the compressed air.
2.3
Training of qualified personnel
Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers. The qualified personnel have skills and
experience in dealing with pneumatic (open-loop) control technology.
3
Additional information
Contact the regional Festo contact if you have technical problems
è
www.festo.com.
Accessories
è
www.festo.com/catalogue.
4 Product design
1
2
3
4
5
6
7
8
Fig. 1:
Service unit MS4-EM1FR-...-B
1
Pneumatic port P2
2
Pressure gauge
3
Release button
4
Filter bowl
5
Drain screw
6
Pneumatic port P1
7
On-off valve rotary knob
8
Filter regulator rotary knob
5 Assembly
5.1 Wall mounting
Shut-off valves are installed in the compressed air supply line.
Fasten the product to the mounting surface with the mounting accessories
è
3 Additional information.
6 Installation, pneumatic
1. Screw the fittings into the pneumatic ports.
2. Note the maximum screw-in depth of the connector thread. Screwing in
deeper will reduce the flow rate and can damage the housing. Maximum
screw-in depth:8.5mm
3. Note the maximum screw-in depth of the connector thread. Screwing in
deeper will reduce the flow rate and can damage the housing. Maximum
screw-in depth:13.5mm
4.
Insert suitable tubing into the fitting to the stop.
Position tubing axial to the pneumatic ports.
Do not bend the tubing more than the minimum bending radius.
7
Commissioning
1.
Unlock the filter regulator rotary knob [8] by pulling it.
2. Turn the filter regulator rotary knob [8] anti-clockwise in the – direction to the
stop.
3. Pressurise the system slowly:
The on/off valve rotary knob [7] is fitted with a lock function. When using
the lock function: open and remove the lock.
Turn the on/off valve rotary knob [7] anticlockwise to the stop, 90°. The
housing will overflow when the rotary knob is turned to its end positions
during pressurisation and exhaust of the on/off valve.
Turn the filter regulator rotary knob [8] in the + direction until the desired
pressure is reached.
4.
Maintain the permissible pressure regulation range
è
11Technical data.
5.
Press the filter regulator rotary knob [8] to lock it.
8 Cleaning
Clean the outside of the product as required with a soft cloth.
Permissible cleaning agents:
Soap solution, maximum +60°C
Petroleum ether, free of aromatic compounds
9 Fault clearance
Malfunction Cause Remedy
Low flow rate (operating pres-
sure is lost with air consump-
tion).
Constriction in the supply line.
Check the line.
The filter cartridge is dirty.
Replace the filter cartridge
è
1 Applicable documents.
The pressure increases above
the set working pressure.
The valve disc at the sealing
seat is defective.
Replace the product.
Continuous audible blowing
noise at rotary knob
The valve seat is damaged.
Replace the product.
Audible blowing noise at the
drain screw.
The drain screw is leaking.
Replace the product.
Tab. 2:
Fault clearance
10 Disassembly
1.
Exhaust the complete system and the product.
2. Release interlock at the fittings by pressing it and pull out the tubing lines.
3.
Release and unscrew the fittings at the connecting flanges.
11
Technical data
11.1
Technical data, mechanical
MS4-EM1FR-...-B -M -VC
Mounting position [°] Vertical±5
Condensate drain function Manual rotating Manual non-detenting
Fully automatic
Vibration resistance in accord-
ance with IEC 60068-2-6
Severity level 1
Shock resistance in accordance
with IEC 60068-2-27
Severity level 1
Pneumatic port P1 G1/4
Pneumatic port P2
Temperature of medium [°C] –5…+50 5…50
Ambient temperature [°C] –5…+50 5…50
Storage temperature [°C] –5…+50
Tab. 3:
Technical data, service unit MS4-EM1FR-...-B
MS4-LFR-...-B
Technical data, mechanical
è
1 Applicable documents
Tab. 4:
Technical data, filter regulator MS4-LFR-...-B
Type of severity level (SL)
Vibration load
Frequency range [Hz] Acceleration [m/s
2
] Deflection [mm]
SL1 SL2 SL1 SG2 SL1 SL2
2 8 2 8 3.5 3.5 ± ±
8 27 8 27 10 10
27 58 27 60 0.15 0.35 ± ±
58 160 60 160 20 50
160 200 160 200 10 10
Shock load
Acceleration [m/s
2
] Duration [ms] Shocks per direction
SL1 SL2 SL1 SL2 SL1 SL2
± ±150 300 11 11 5 5
Continuous shock load
Acceleration [m/s
2
] Duration [ms] Shocks per direction
±150 6 1000
Tab. 5: Type of severity level (SL)
11.2
Technical data, pneumatic
MS4-EM1FR-...-B -M -VC
Operating medium Compressed air to ISO 8573-1:2010[7:4:4]
Information on the operating medium
Information on the operating
medium
Lubricated operation possible, in which case lubricated
operation will always be required
Not compatible with ester oil
Pressure regulation range [MPa] 0.03…0.7
[bar] 0.3…7
[psi] 4.35…105
Operating pressure [MPa] 0.1…1 0.2…1
[bar] 1…10 2…10
[psi] 15…145 29…145
Air purity class at the output
MS4-LFR-...-C
Grade of filtration 5µm
Compressed air to ISO 8573-1:2010[6:4:4]
MS4-LFR-...-E
Grade of filtration 40µm
Compressed air to ISO 8573-1:2010[7:4:4]
Standard nominal flow rate
MS4-LFR-...-C
Grade of filtration 5µm
[l/min] 1500
MS4-LFR-...-E
Grade of filtration 40µm
[l/min] 1700
Tab. 6: Technical data, service unit MS4-EM1FR-...-B
MS4-LFR-...-B
Technical data, pneumatic
è
1 Applicable documents
Tab. 7: Technical data, filter regulator MS4-LFR-...-B


Product specificaties

Merk: Festo
Categorie: Niet gecategoriseerd
Model: MS4-EM1FR-1/4-D6-C-P-VC-AG-MPA-WPE-B

Heb je hulp nodig?

Als je hulp nodig hebt met Festo MS4-EM1FR-1/4-D6-C-P-VC-AG-MPA-WPE-B stel dan hieronder een vraag en andere gebruikers zullen je antwoorden