Bekijk gratis de handleiding van Fantini Cosmi Sicurgas P12 (8 pagina’s), behorend tot de categorie Gasmelder. Deze gids werd als nuttig beoordeeld door 4 mensen en kreeg gemiddeld 3.8 sterren uit 2.5 reviews. Heb je een vraag over Fantini Cosmi Sicurgas P12 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/8

P11-P12
GAS LEAK DETECTORS
FOR METHANE AND LPG
INSTRUCTIONS FOR USE
FANTINI COSMI S.p.A.
Via dell’Osio, 6 20090 Caleppio di Settala, Milano - ITALY
Ph. +39 02 956821 | Fax +39 02 95307006 | info@fantinicosmi.it
www.fantinicosmi.it

2
1
WALL MOUNTING
Sicurgas P11 and P12 it is a device, that through
a sensitive sensor, detects methane gas
concentration (P11) and LPG concentration (P12) in
domestic environments.
Sicurgas P11 and P12 are operating when the gas
concentration in the air is much below of the lower
explosion limit (L.E.L.).
In case of alarm, interferes as well an acoustic
and light alarm that is going to prevent the danger.
Simultaneously Sicurgas is making the relay to
interfere to control the gas interception valve.
EXISTS THE POSIBILITY THAT YOU FEEL THE
GAS SMEL BEFORE THE DEVICE GIVES AN
ALARM SIGNAL.
Gas detectors Sicurgas P11 and P12, when are
connected to a normally closed (NC) valve with
manual reset are giving positive safety. This
means that the gas interception valve is closing to
interrupt the inflow, as well in case of line voltage
absence.
For having the maximum security can be used
more gas detectors Sicurgas, connected to the
same gas interception valve.
For e.g. can be mounted a P11 (P12) in the place
where is installed the boiler and another one in the
kitchen to control the stoves.
Sicurgas is supplied with a base suitable for
mounting in built-in boxes with 3 modules or in
round boxes.
Remove the base/cover retaining screw and ease off
the cover.
Fix the base on the wall (see paragraph 3) or in a
built-in box using rear entry for the entries of the
connection cables.
ATTENTION!
DO NOT OPEN THE DEVICE, BECAUSE
THIS MAY CAUSE ELECTRICAL SHOCKS OR
MALFUNCTION.
ATTENTION
gas detector installation is not released
from compliance with all rules regarding
features, installation and use of the gas
appliances, ventilation of the rooms and the
discharge of the combustion products prescribed
by the EN norms, implementation of the Art. 3 of
the law 1083/71 and of the national legislation
in force. Before installing the device, it is
recommended to read carefully this instruction
manual.
for built-in boxes 503
with modules
for round built-in
boxes
pre-fractured area
to increase the
space required for
wiring
A
B
I N S T A L L A T I O N
S i c u r g a s
After executing the mounting and the connections (see 4) replace the cover on the base ensuring paragraph
the two cover pegs are correctly located on the two latching tabs. Screw again the fixing screw and apply in
the corresponding place the provided adhesive label indicating the replacement date.
B 60 mm
A 83,5 mm
GREEN LED
power supplied device
YELLOW LED
defective detector
RED LED
ALARM - gas concentration
is higher than the alarm
threshold
fixing srew
base-cover

3
2
3
4
SICURGAS PLACEMENT
EXAMPLES OF CONNECTION
ELECTRICAL CONNECTIONS
Sicurgas P11 must be fixed on the wall, about 30
cm from the ceiling and at a distance from gas
user device, between a minimum of 1 meter and a
maximum of 4 meters, in such position as to allow
natural air circulation.
Sicurgas P12 must be installed approximately 2
meters (minimum 1m maximum 4m) from the gas
user device and about 30 cm from the floor.
Sicurgas P11 is already equipped with two internal
alarms: one visible and one acoustic.
Just connect the line 230V c.a. 50Hz to the
terminals 4 and 5 to ensure the gas presence
signaling in the environment.
It is recommended to use a valve with manual
reset to stop the gas supply when there is an alarm
situation.
The internal relay can control all kind of power
supplied valves with manual reset:
normally closed (NC), always power supplied,
which require a commutating stable relay;
normally opened (NO), which require an
impulse relay.
Example of connection with stable relay, always
power supplied, to control a normally closed valve
with manual reset (down switch).
The system guarantees maximum safety, the gas
inflow will be stopped in case of:
gas concentration threshold exceeding;
power supply lack of the valve only or of the
detector;
connection breakdown between the detector
and the valve.
For device power supply, connect
the terminals 4 - 5 to the circuit
230V-50Hz.
Relay operating mode can be chose in the
installation moment, by moving a switch (JP6) on
the printed circuit, normally supplied for functioning
with stable relay for NC valves (down switch).
G A S L E A K D E T E C TO R S
F O R M E T H A N E A N D L P G
ATTENTION!
DO NOT place the device behind or under
cabinets or shelves that are not allowing the
natural air circulation in environment.
DO NOT place it near aerators (minimum distance 2
meters).
DO NOT place it on the vertical bakery surfaces,
steam sources, in places where can be achieved by
splashing water, near sinks, etc.
DO NOT place where environmental conditions are
different from the prescribed operation conditions.
NC
L
N
switch JP6 in
down position
(B)
predisposed in the
factory
stable relay for normally
closed NC valves with
manual reset
switch JP6 in
up position (A)
impulse relay for
normally opened NO
valves
with manual reset
possible
external
alarm
P11-P12
S i c u r g a s
max. 30 cm
min. 1 mt
max. 4 mt
GPL
max. 30 cm
min. 1 mt
max. 4 mt
Product specificaties
Merk: | Fantini Cosmi |
Categorie: | Gasmelder |
Model: | Sicurgas P12 |
Heb je hulp nodig?
Als je hulp nodig hebt met Fantini Cosmi Sicurgas P12 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Gasmelder Fantini Cosmi
5 Juli 2025
11 Mei 2025
26 Maart 2025
7 Juni 2023
19 Mei 2023
26 Februari 2023
19 Februari 2023
18 Februari 2023
11 Februari 2023
10 Februari 2023
Handleiding Gasmelder
- WisuAlarm
- Techly
- Abus
- First Alert
- Popp
- Gloria
- Nexa
- System Sensor
- Vemer
- Eminent
- Joy-it
- Itron
- Satel
- HQ
- Trotec
Nieuwste handleidingen voor Gasmelder
5 Juli 2025
10 Juni 2025
22 Mei 2025
4 Maart 2025
11 December 2024
30 November 2024
24 November 2024
18 November 2024
17 November 2024
22 Oktober 2024