Fantini Cosmi O70RL Handleiding


Bekijk gratis de handleiding van Fantini Cosmi O70RL (1 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 6 mensen en kreeg gemiddeld 4.9 sterren uit 3.5 reviews. Heb je een vraag over Fantini Cosmi O70RL of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/1
Attachment
M30x1.5
Radio band
EU868
RF power
< +14dbm
Radio modulation
LoRa
via radio (OTA)
Power supply
2 alkaline batteries 1.5V – LR6 – AA
(do not use rechargeable batteries)
Autonomy
up to 24 months (dependent on mode of use)
TECHNICAL DATA
Temperature display Celsius C)
Temperature adjustment scale 2
÷
30 °C; increment 0.1 °C
Operating temperature
0 to 40°C
Storage temperature -20
÷
65 °C
Relative storage humidity 20
÷
80% (90% without condensation)
Protection rating IP30
Size
89.8 x Ø 54.2 mm
Directive 2014/30/EU (EMC); Directive 2014/35/EU (LVD); Directive 2014/53/EU (RED)
Product not manufactured in Italy.
At any time it is however possible to activate the radio function and associate the O70RL
with the Fantini Cosmi RL multi-zone temperature control system (chapter 2.1 - RADIO
SYSTEM CONFIGURATION).
ENG
WIRELESS RADIATOR THERMOSTAT
4 - CHANGING SETTINGS
1. To change settings, activate the display and press the dial for 15 seconds until the Insscreen
appears, then release;
15 sec.
2. Turn the dial to select the parameter you wish to change (see list) and press SETTINGS MENU
to enter;
3. Turn the dial to select the desired value and press to confirm. When released, a flash confirms
the saving of changes;
4. To exit the settings menu completely, wait 10 seconds or press the dial for 3 seconds.
3 sec.
SETTINGS MENU
Setting brightness
The default value can be changed to adjust the brightness of the display.
Default value = 03
01 (min) - 05 (max)
Room temperature display
When this function is enabled, the display will show the detected room temperature when it is
switched on.
Default value = OFF (disabled)
OFF = Turning the dial always displays the desired temperature
ON = Pressing the dial to switch on the display shows the room temperature
Display orientation
Allows you to change the desired display orientation.
Correction of detected temperature (OFFSET) *
If you notice a gap between the temperature measured in the room (thermometer) and the
temperature displayed on the valve, you can correct the value to be displayed.
Default value = 0°C
-5 - 5
Minimum temperature limit *
A user-settable minimum temperature threshold (Set Point) can be set.
Default value = 2°C
2.0 °C ÷ tH
Maximum temperature limit *
A maximum temperature threshold can be set by the user (Set Point).
Default value = 30°C
tL ÷ 30.0 °C
Anti-seize
The frequency of automatic forced valve actuation can be set. This function remains active
even when the thermostat is in OFF mode.
Default value = 30 days
1 - 99, OFF
View release
The display shows the firmware and hardware version installed on the device.
Temperature control modes
Displays the valve setting mode.
LOc = room temperature reading from O70RL (default)
Ren = room temperature reading from remote thermostat (if present)
dC = direct control
Open window function
When this function is enabled, the device goes into OFF when an abrupt
drop in room temperature is detected, avoiding energy waste, and the
open window icon appears on the display.
To restore normal operation, wait 30 minutes or use the control dial.
Default value = OFF (disabled)
OFF = Function disabled
ON = Function enabled
* Function only available for stand-alone use. If connected to the multi-zone system, the parameter
will be managed by the CH180WIFIRL master device.
1 - DESCRIPTION
Ring nut
Thermostatic head
and battery cover
Adjustment and
confirmation dial
Display
Safety lock
Radio signal
Set piont temperature /
room temperature
Low battery warning
Open window function active
O70RL can be mounted either vertically or horizontally.
O70RL installs on all thermostat valves with M30x1.5 connection;
If necessary, use the most suitable adapter (not included in the package) for other valve
types:
CODE DESCRIPTION
309703A IRSAP/CALEFFI valve adapter
309704 Giacomini valve adapter
309706A FAR valve adapter
2
2
2
22
tate the O70RL body so that the display is in a clearly visible position.
3
3
3
33
fine the orientation of the display by turning the dial until the word is correctly UP
positioned; confirm by pressing the dial.
5
5
5
55
dio activation:
Combination with multi-zone temperature control system
Select YES to associate the thermostat with the Fantini Cosmi RL multi-zone
temperature control system (chapter 2.1 - RADIO SYSTEM CONFIGURATION -
paragraph 2). To exit the radio pairing phase, perform a reset as per point
4.1 - RESTORING FACTORY SETTINGS.
Using the device in stand-alone mode
Select NO to use the device without association with the Fantini Cosmi RL
multi-zone temperature control system.
6
6
6
66
4.1 - RESTORING FACTORY SETTINGS
Remove the battery compartment cover;
Press and hold the reset button until the display is reset;
Replace the cover and repeat the initial installation procedure (Chapter 1 - INSTALLATION - paragraph 4).
*
* when combined with CH180WIFIRL
nsert the cover;
O70RL will perform automatic calibration which will also occur also
each time the cover is reinserted. During the calibration phase, the
screen shown here is displayed.
In the event of a calibration error, the screen Erc
appears on the display. Check that the valve is properly secured or
check the condition of the batteries.
4
4
4
44
3.4 - OPEN WINDOW FUNCTION
When this function is enabled (see Chapter ), the device goes into OFF when 4 - CHANGING SETTINGS
an abrupt drop in the room temperature is detected, avoiding energy waste.
move the thermostat cover and insert two AA 1.5 V batteries, observing correct polarity;
1.5V LR6 (AA)
1.5V LR6 (AA)
The initial screen will flash on the display:
Screw the ring nut of the thermostat onto the threaded connection of the radiator valve.
1
1
1
11
2 - INSTALLATION
3.2 - SETTING THE TEMPERATURE
With the display active, turn the dial to raise or lower the desired temperature.
To confirm, wait a few seconds or press the rotary dial; a flash
indicates that the changes have been saved.
Lowering the temperature beyond the minimum limit will
activate the “OFF” mode and the antifreeze function at 2°C.
2.1 - RADIO SYSTEM CONFIGURATION (OPTIONAL)
Activate the radio function by pressing and holding the rotary dial for 10 seconds after activation
of the display, until the screen appears:rF
10 sec.
Perform pairing from the CH180WIFIRL master device by selecting the MAC address of the
thermostat to be paired (as shown on the label located under the cover).
MAC address
QR code for Intelliclima+ App
Alternatively, the thermostat can be associated with the CH180WIFIRL master device directly
from the Intelliclima+ application by framing the QR code on the label.
To confirm successful association with the CH180WIFIRL, the desired
temperature (default 20.0 °C) and the radio icon appear on the thermostat
display:
At any time, it is possible to exit the radio pairing phase by resetting the device as indicated
under .4.1 - RESTORING FACTORY SETTINGS
3 - USE
3.1 - SWITCHING ON THE DISPLAY AND TEMPERATURE DISPLAY
After 5 seconds of inactivity, the O70RL will go into stand-by mode, switching off
the display. To reactivate the display, press or turn the control dial slightly. The
desired temperature appears on the display (default 20.0 °C).
When the batteries are running low, the icon flashes once every hour. When the batteries are completely
depleted, it will no longer be possible to operate the device, which will go to OFF.
Low battery test: remove and replace cover. If the low battery symbol flashes, this means that the
batteries are running low and need to be replaced.
LOW BATTERY WARNING
To deactivate the safety lock function, with the display active, press the dial again for 5 seconds until
the lock icon disappears from the display.
3.3 - SAFETY LOCK
With the display active, it is possible
to deactivate the setting change by
pressing the dial for 5 seconds until the
LOc screen appears.
Activation of the function is confirmed
by the presence of the lock icon on the
display.
5 sec.
Thank you for purchasing the Fantini Cosmi wireless radiator thermostat, model O70RL.This manual
contains all the information required for a correct installation and use. You can also download this manual
in digital format and in several languages by framing the QR code below and entering the product code.
FANTINI COSMI S.P.A.
Via Dell’osio, 6 - 20049 Caleppio di Settala (Mi) - ITALY
Email: info@fantinicosmi.it - www.fantinicosmi.it
O
70RL
O70RL
pdf.fantinicosmi.it
ITALIANO
ENGLISH
FRANÇAIS
ESPAÑOL
DEUTSCH
РУССКИЙ
УКРАЇНСЬКИЙ
...


Product specificaties

Merk: Fantini Cosmi
Categorie: Niet gecategoriseerd
Model: O70RL

Heb je hulp nodig?

Als je hulp nodig hebt met Fantini Cosmi O70RL stel dan hieronder een vraag en andere gebruikers zullen je antwoorden