Bekijk gratis de handleiding van Extech MO57 (24 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 14 mensen en kreeg gemiddeld 4.4 sterren uit 8 reviews. Heb je een vraag over Extech MO57 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/24

MO57--/17 enGB_V1.0 7
1
USER MANUAL
Pinless Moisture Meter
Model 57MO
Introduction
Thank you for selecting 57 employs a the Extech MO57 MPinless oisture Meter. The MOnon-
destructive spherical sensor that safely glides over surfaces to measure the relative moisture in
wood and other building materials (board, sheet rock, cardboard, pwalllaster, concrete, and mortar)
at any angle to a depth of 10.2cm (4”).
To indicate moisture MO57 provides a digital readingaudible tonesand ‘moisture droplevel the , , let’
icons. Audi ble tones (eight levels of intensity) and droplet icons (1, 2, or 3) increase in proportion to
increased moisture. Additional features include Auto Power OFF and Display Lock (hold).
This meter ships fully tested and calibrated and, with proper use, will provide years of reliable
service. Please visit our website () to check for the latest version of this User Guide, www.extech.com
Product Updates, and Customer Support.
Measurement Considerations
To measure moisture, the sensor emits and senses low--power electromagnetic signals. The
displayed reading in percent is an average of the moisture content measured over the measurement
surface area and the maximum depth of penetration ..0(10 2cm [4”]). Moisture that is closer to the
surface has a greater effect on the displayed average than the moisture nearer to the maximum
depth of penetration.
Placing the sensor on a surface whose thickness is less than the maximum depth of penetration may
result in unreliable moisture readings; in these cases, you can stack material on top of the measured
surface to increase the thickness.
The MO57 also produces audible tones and ‘moisture droplet’ display icons to indicate moisture
level. The audible tone rate and number of droplets increase as the moisture level increases. When
measuring, keep hand stationary on the meter while holding and moving the meter, as hand
movement can affect the readings.
Meter Description
1. LCD Display
2. Power button
3. Display Lock/Beeper button
4. Material Select button
5. Sensor
NoteBatt: ery compartment on rear of meter
Display Description
1. Dropleticons(1 for low moisture, 2 for medium, and 3 for high)
2. Wood mode
3. Building Material mode
4. Beeper active icon
5. Moisture reading
6.Percent moisture unit (relative)
7. Display Lock mode
8. Battery status icon
Button Descriptions
Symbol
Button name
Description
Power - ONOFFLong press to switch the meter ON or OFF
/
Material Select (wood/building
materials)
Short press to toggle material groups
/ Display Lock / Beeper control
Short press locks/unlocks reading on the display
Long press toggles the Beeper ON/OFF
Operation
Powering the Meter
1. . Long press the power button to turn the meter ON/OFF
2.The meter emits audible tones andcalibration upon startKeep the -performs a self-up.
measurement sensor at least 8 to 10 cm (3 to 4”) from hands and during calibrationobjects .
The calibration reading must not exceed 0.5. If so, recalibrate ensuring that hands or other -
objects are clear of the sensor.enever Note: Calibrate the meter whmoving from one
measurement area to another.
3.If the battery symbol appears or if the meter does not switch ON, . replace the battery
1
23
4
5
Product specificaties
| Merk: | Extech |
| Categorie: | Niet gecategoriseerd |
| Model: | MO57 |
Heb je hulp nodig?
Als je hulp nodig hebt met Extech MO57 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Extech
29 November 2025
27 November 2025
26 November 2025
25 November 2025
25 November 2025
26 Augustus 2025
25 Augustus 2025
25 Augustus 2025
25 Augustus 2025
22 Oktober 2024
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
23 Januari 2026
23 Januari 2026
23 Januari 2026
23 Januari 2026
22 Januari 2026
22 Januari 2026
22 Januari 2026
22 Januari 2026
22 Januari 2026
22 Januari 2026