Extech MN47 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Extech MN47 (14 pagina's) in de categorie Multimeter. Deze handleiding was nuttig voor 39 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/14
User's Guide
Autoranging Multimeter
Model MN47
MN47-EU-EN-V3.0–12/11 2
Introduction
Congratulations on your purchase of the MN47 MultiMeter. The MN47 offers AC/DC Voltage, AC/DC
Current, Resistance, Diode, and Continuity and Temperature. Proper use and care of this meter will
provide many years of reliable service.
Safety
This symbol adjacent to another symbol, terminal or operating device indicates
that the operator must refer to an explanation in the Operating Instructions to
avoid personal injury or damage to the meter.
This WARNING symbol indicates a potentially hazardous situation, which if not
avoided, could result in death or serious injury.
This CAUTION symbol indicates a potentially hazardous situation, which if not
avoided, may result damage to the product.
This symbol advises the user that the terminal(s) so marked must not be
connected to a circuit point at which the voltage with respect to earth ground
exceeds 600V.
This symbol adjacent to one or more terminals identifies them as being associated
with ranges that may, in normal use, be subjected to particularly hazardous
voltages. For maximum safety, the meter and its test leads should not be handled
when these terminals are energized.
SAFETY INSTRUCTIONS
This meter has been designed for safe use, but must be operated with caution. The rules listed
below must be carefully followed for safe operation.
1. NEVER apply voltage or current to the meter that exceeds the specified maximum:
Input Protection Limits
Function Maximum Input
V DC or V AC 600V AC and DC
mA AC/DC 400mA DC/AC
A AC/DC 10A DC/AC (for 30 seconds max. every 15 minutes
Frequency, Resistance, Capacitance,
Duty Cycle, Diode, Continuity,
Temperature
250V DC/AC
2. USE EXTREME CAUTION when working with high voltages.
3. DO NOT measure voltage if the voltage on the "COM" input jack exceeds 600V above earth ground.
4. NEVER connect the meter leads across a voltage source while the function switch is in the current, resistance, or
diode mode. Doing so can damage the meter.
5. ALWAYS discharge filter capacitors in power supplies and disconnect the power when making resistance or diode
tests.
6. ALWAYS turn off power and disconnect test leads before opening the covers to replace the fuse or battery.
7. NEVER operate the meter unless the back cover and the battery and fuse covers are in place and fastened securely.
8. DO NOT use the meter if the meter or test leads look damaged, or if you suspect the meter is not operating properly.
9. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may
be impaired.
WARNING
CAUTION
MAX
600V
MN47-EU-EN-V3.0–12/11 3
Controls and Jacks
1. Non-Contact AC voltage tester
2. 4000 count LCD display
3. RANGE button
4. MODE button
5. HOLD button
6. RELATIVE button
7. Function switch
8. COM (negative) input jack
9. Positive 10A input jack
10. Positive input jack
Symbols and Annunciators
•))) Continuity
Diode test
+
Low battery
HOLD Data hold
Auto Autoranging
AC Alternating current
DC Direct current
REL Relative
µ micro (amps)
m milli (volts, amps)
k kilo (ohms)
Ω Ohms
1
2
3
4
5
6
7
8
910


Product specificaties

Merk: Extech
Categorie: Multimeter
Model: MN47

Heb je hulp nodig?

Als je hulp nodig hebt met Extech MN47 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Multimeter Extech

Handleiding Multimeter

Nieuwste handleidingen voor Multimeter