Extech DCP36 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Extech DCP36 (10 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 32 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/10
USER MANUAL
Model DCP36
80W Switching DC Power Supply
User Manual Translaons available at www.extech.com
2 DCP36- - _V1.2 /20en US 12
Introducon
Thank you for selecng the Extech DCP36 laboratory grade W Switching DC Power Supply. The 80
DCP36 is auto-ranging and oers a 0.5~36V and 0~5A output capability. Its maximum current
output at 36V is 2.2A (80W/36V). The maximum voltage output at 5A is 16V (80W/5A).
The voltage/current spectrum is greater than three convenonal power supplies of the same
power rang. Adjustable Upper Voltage/Current Limit features protect sensive devices from
wide output variaons. Three user presets allow for easy programming and recall of commonly
used output conguraons. Master/Slave capability for up to 30 units in parallel connecon. The
DCP is perfect fo benchwork, eld service and hobbyists. 36 r ,
The DCP36 is shipped with the following accessories: AC power cord, RJ11 cable, alligator clip test
leads, and an RJ11 terminator plug.
This power supply is shipped fully tested and calibrated and, with proper use, will provide years of
reliable service lease visit the Extech website for the latest user manual and for customer . P
support.
Safety
This manual contains importa informaon illustrang the safe and proper use of th power nt is
supply. Read the enre manual and carefully observe the markings and labels this unit and on on
the equipment to which it will be connected.
Failure to observe may cause injury to persons and damage to the power supply or the connected Warnings
equipment. Failure to observe Cauon statements may result in damage to connected equipment improper and
funconing of the power supply.
WARNINGS
1. Do not use this power supply near water.
2. Do not operate or touch this power supply with wet hands.
3. Do not open the casing of the power supply when it is connected to mains. AC
4. Refer all servicing, including fuse replacement, to qualied service personnel.
CAUTIONS
1. Use a grounded 3-terminal source. AC
2. This t is intended for indoor use only. uni
3. Do not operate or place this unit in a humid or dusty environment.
4. Do not expose this device to direct sunlight or place it near a source of heat.
5. Before plugging into the local AC mains, check the rang label at the ck of the unit. ba
6. Do not block any of the venlaon openings the unit. on
7. This unit must be used within the specified ratings; Continuous and excessive loading may cause damage to
the power supply.
8. The gauge size of input power cable must be at least 0. m75m 2 (18awg) and the total length of power
cable must not exceed 3m (10).
3 DCP36- - _V1.2 /20en US 12
Power Supply Descripon
Front and Back Descripons
1. Output Voltage Display
2. Output Current or Power Display
3. SLAVE-SHIFT-LOCK funcon indicators
4. Output ON-OFF buî‡șon and indicator
5. Output preset selecon buî‡șons and indicators
6. LOCK and Amp/Waî‡ș-meter buî‡șon
7. MENU and SHIFT buî‡șon
8. Power ON-OFF switch
9. Output terminal egave) (n
10. Output terminal (posive)
11. Current output justment ad
12. Voltage output adjustment
13. Constant Current indicator
14. Constant Voltage indicator
15. Remote Sensing (RS) terminals
16. Alternate output (O/P) terminals
17. 11 Master RJ jack
18. 11 Slave RJ jack
19. Earth Ground terminal
20. AC power jack
Note that there is an addional RJ11 jack on the back of the unit
labeled ‘Reserved’ that is unused in this model
Display Descripons
Constant Voltage mode (C.V. indicator)
The output voltage is kept constant at the set voltage. The
DCP36 remains in CV mode if the load current is lower than
the set current limit otherwise it will switch to CC mo , de.
Constant Current mode (C.C. indicator)
When the load is higher than the set current limit of the set
voltage in CV mode, the Constant Current mode is acve.
The output current is kept constant at the set current level
provided that the loading is suciently large to draw
current equal to or larger than the set current, otherwise it
will switch to the CV mode.