Bekijk gratis de handleiding van Extech AUT30 (1 pagina’s), behorend tot de categorie Meetapparatuur. Deze gids werd als nuttig beoordeeld door 24 mensen en kreeg gemiddeld 4.0 sterren uit 8 reviews. Heb je een vraag over Extech AUT30 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/1
USER MANUAL
AU0-AUT30M-en-GB_V1.1 4/17 T3
Model AUT30 and AUT30M
Automotive 30A Current Testers
Features
Large digit LCD display
or mini- blade size fuse circuits (AUT30M)
Measuring range to 30A/48VDC (10 sec. test time max.)
Safety
WARNING: Risk of Electrocution. Keep hands and fingers on
the body of the probe and away from the blade tips.
CAUTION: Read, understand and follow Safety Rules and
Operating Instructions in this manual before using meter.
Do not attempt to repair this unit. There are no user
serviceable parts.
Do not expose unit to extreme temperatures/high humidity
Do not use the unit if it is wet or damaged
Do not apply more than the rated voltage between the probe
tip and ground.
Do not operate with the case open
This symbol, adjacent to another symbol or terminal,
indicates the user the user must refer to the manual
for further information.
This symbol, adjacent to a terminal, indicates that,
under normal use, hazardous voltages may be present
Double insulation
Specifications
Range 0 to 30A DC / 48V DC
Resolution 10mA
Accuracy ± (2.0% ofreading+ 2 digits)
Detection distance <0.2
Operating Temperature 0 to 50
o
C (32 to 122
o
F)
Storage Temperature20 to 60 -
o
C (-4 to 140
o
F)
Altitude 2000 meters(7000 ft.) maximum
Relative Humidity 80% up to 31
o
C (88
o
F), decreasing to
50% at 50
o
C (122
o
F)
Battery 1 x A23G 12Vbattery
Dimensions/Weight159 x 25mm (6.25 x 1) ) / 42g (1.5oz.
Cable length 71cm (2.3 )ft.
Operating Instructions
1.With the vehicle ignition OFF, remove the fuse from the
circuit to be tested and set it aside.
2.Insert the meters fuse blades (3) into the jack from where
the fuse was removed.
3.Insert the removed fuse into the meters fuse jack (4).
4.Press the meters On/Off button (2)
5.Operate the circuit under test for up to 10 seconds only; the
LCD (1) will display the measured current.
6.When finished press the On/Off button to turn off the tester.
7.WARNING! The Fuse blade may become hot during testing.
Allow to cool before removing. Do nottest > 10 seconds.
BATTERY INSTALLATION
1.To replace the battery, remove the screw from the back of
the unit and remove the cover.
2.Insert one 12V A23G battery (observe polarity).
3.Replace the battery cover
NOTE: If the meter does not work properly, check the
battery to ensure that its fresh and properly inserted.
Battery Safety
Never dispose of batteries in a fire; batteries may explode or
leak.
Never dispose of used batteries or rechargeable
batteries in household waste.
As consumers, users are legally required to take used
batteries to appropriate collection sites, the retail
store where the batteries were purchased, or
wherever batteries are sold.
Disposal: Do not dispose of this instrument in household waste. The
user is obligated to take endes to a designated collection -of-life devic
point for the disposal of electrical and electronic equipment.
Copyright © - 20132017FLIR Systems, Inc.
All rights reserved including the right of reproduction in whole or in part in any form
ISO-9001 Certified
www.extech.com